{"_buckets": {"deposit": "06184b7a-ae6b-4e7c-8067-65f25c01e2da"}, "_deposit": {"created_by": 3, "id": "13098", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13098"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013098", "sets": ["1134"]}, "author_link": ["20730", "20732", "529", "20731"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-06-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "SUPPL.7", "bibliographicPageEnd": "364", "bibliographicPageStart": "362", "bibliographicVolumeNumber": "1", "bibliographic_titles": [{"bibliographic_title": "Computer-Assisted Radiology and Surgery"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Accessory cardiac bronchus (ACB) is a rare bronchial anomaly This anomaly often goes undetected due to its low frequency and lack of symptoms in most cases. However, ACB should be diagnosed because it sometimes causes infection and/or hemoptysis. Here, we present a rule-based and 2D-based scheme, which can detect ACB in chest multi-slice computed tomography volume data. We have developed a computer-aided scheme for detection of ACB. This scheme performs extraction of the bronchial tree structure, determination of trachea bifurcation, and detection of ACB on the right bronchi. The sensitivity and specificity of this scheme were evaluated in 9 cases: 3 with ACB. 3 with tracheal bronchus and no ACB, and 3 normal cases. All of the subjects were examined with MSCT scanners (LightSpeed Ultra 16 and LightSpeed Plus; GE Medical Systems, Milwaukee. WI, USA) using a contiguous slice thickness of 2.5 mm. We also measured the time taken for examination using the scheme on a personal computer (CPU: 2.4 GHz Pentium 4, Memory: 1 Gbyte; OS: Red Hat Linux 9). The scheme detected ACB in two of the three cases (Sensitivity: 66.7%), and all of the cases without ACB were identified as having no ACB (Specificity: 100%). The mean processing time was 13.5 seconds (SD: 6.4) per case, and therefore this scheme could be suitable for prechecking before actual diagnosis.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学大学院医学系研究科", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Verlag"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1861-6410", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takemura, Akihiro"}], "nameIdentifiers": [{"nameIdentifier": "529", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70313674"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70313674"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070313674"}]}, {"creatorNames": [{"creatorName": "Suzuki, M."}], "nameIdentifiers": [{"nameIdentifier": "20730", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Harauchi, H."}], "nameIdentifiers": [{"nameIdentifier": "20731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okumura, Y."}], "nameIdentifiers": [{"nameIdentifier": "20732", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-TAKEMURA-T-01.pdf", "filesize": [{"value": "372.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 372200.0, "url": {"label": "ME-PR-TAKEMURA-T-01.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13098/files/ME-PR-TAKEMURA-T-01.pdf"}, "version_id": "06a38728-d2c3-4153-9385-1a88a72c32f6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Accessory cardiac bronchus", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Bronchial anomaly", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computer-aided detection", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Rule-based scheme", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/2859", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13098", "relation": {}, "relation_version_is_last": true, "title": ["A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images"], "weko_shared_id": 3}
A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images
http://hdl.handle.net/2297/2859
http://hdl.handle.net/2297/285973c10049-c6d3-476e-957f-e9f3c4e481f9
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-TAKEMURA-T-01.pdf (372.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Takemura, Akihiro
× Takemura, Akihiro× Suzuki, M.× Harauchi, H.× Okumura, Y. |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学大学院医学系研究科 | |||||
書誌情報 |
Computer-Assisted Radiology and Surgery 巻 1, 号 SUPPL.7, p. 362-364, 発行日 2006-06-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1861-6410 | |||||
出版者 | ||||||
出版者 | Springer Verlag | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Accessory cardiac bronchus (ACB) is a rare bronchial anomaly This anomaly often goes undetected due to its low frequency and lack of symptoms in most cases. However, ACB should be diagnosed because it sometimes causes infection and/or hemoptysis. Here, we present a rule-based and 2D-based scheme, which can detect ACB in chest multi-slice computed tomography volume data. We have developed a computer-aided scheme for detection of ACB. This scheme performs extraction of the bronchial tree structure, determination of trachea bifurcation, and detection of ACB on the right bronchi. The sensitivity and specificity of this scheme were evaluated in 9 cases: 3 with ACB. 3 with tracheal bronchus and no ACB, and 3 normal cases. All of the subjects were examined with MSCT scanners (LightSpeed Ultra 16 and LightSpeed Plus; GE Medical Systems, Milwaukee. WI, USA) using a contiguous slice thickness of 2.5 mm. We also measured the time taken for examination using the scheme on a personal computer (CPU: 2.4 GHz Pentium 4, Memory: 1 Gbyte; OS: Red Hat Linux 9). The scheme detected ACB in two of the three cases (Sensitivity: 66.7%), and all of the cases without ACB were identified as having no ACB (Specificity: 100%). The mean processing time was 13.5 seconds (SD: 6.4) per case, and therefore this scheme could be suitable for prechecking before actual diagnosis. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |