{"_buckets": {"deposit": "6d19ec4b-5272-407c-b96c-ab74117cc3a8"}, "_deposit": {"created_by": 3, "id": "13378", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13378"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013378", "sets": ["1134"]}, "author_link": ["21863", "21865", "21860", "120", "21861", "21862", "21864", "13188"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "67", "bibliographicPageStart": "64", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "医用画像情報学会雑誌 = Japan Society of Imaging and Information Sciences in Medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We evaluated the R2* (iron content) and fat fraction of the liver tissue simultaneously using modulus and real multiple gradient-echo (MRM-GRE) sequence. On a 1.5-T MRI, modulus images of 7-9 gradient-echoes were obtained by MRM-GRE sequence at a time. A real part of the first echo image was also reconstructed to differentiate below and above the 50 percent fat fraction. The fat fraction and R2* were obtained from the parameters of a theoretically fitted formula with each echo signal. R2* and fat fraction were measured with MRM-GRE in the phantom and the liver in normal volunteers (n=6) and patients with fatty liver (n=4) . MRI-derived fat fraction of the phantom was in good agreement with the actual value, and R2* of the phantom showed a strongly positive correlation with the actual iron content. MRI-derived fat fraction in fatty liver was significantly higher than that in the normal volunteers. However, no significant difference in R2* was found between fatty liver and normal volunteers. These results show that the MRM-GRE enables to differentiate the causes of signal reduction whether increasing R2*or increasing fat fraction. The MRM-GRE method makes it possible to simply and accurately assess the fat content and the iron content.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "医用画象情報学会"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.mii-sci.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/130000138572", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jstage.jst.go.jp/article/mii/26/3/26_64/_article", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2009 by Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10156808", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-1543", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小野, 絵理"}], "nameIdentifiers": [{"nameIdentifier": "21860", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮地, 利明"}], "nameIdentifiers": [{"nameIdentifier": "120", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080324086"}]}, {"creatorNames": [{"creatorName": "大野, 直樹"}], "nameIdentifiers": [{"nameIdentifier": "13188", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30642219", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30642219"}, {"nameIdentifier": "30642219", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30642219"}, {"nameIdentifier": "30642219", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030642219"}]}, {"creatorNames": [{"creatorName": "笠井, 治昌"}], "nameIdentifiers": [{"nameIdentifier": "21861", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "原, 真咲"}], "nameIdentifiers": [{"nameIdentifier": "21862", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "芝本, 雄太"}], "nameIdentifiers": [{"nameIdentifier": "21863", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川野, 誠"}], "nameIdentifiers": [{"nameIdentifier": "21864", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "朝日, 美幸"}], "nameIdentifiers": [{"nameIdentifier": "21865", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MIYATI-T-64.pdf", "filesize": [{"value": "731.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 731400.0, "url": {"label": "ME-PR-MIYATI-T-64.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13378/files/ME-PR-MIYATI-T-64.pdf"}, "version_id": "0e3b44d8-36a2-45d7-a98c-1fcad5cb000f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "magnetic resonance imaging (MRI)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "R2*", "subitem_subject_scheme": "Other"}, {"subitem_subject": "fat fraction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "gradient echo (GRE)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "liver", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "MRM-GRE法を用いた肝臓の鉄含有量および脂肪含有率の同時測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "MRM-GRE法を用いた肝臓の鉄含有量および脂肪含有率の同時測定"}, {"subitem_title": "Simultaneous R2* and Fat Fraction Determination of the Liver with Modulus and Real Multiple Gradient-echo MRI", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/24703", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13378", "relation": {}, "relation_version_is_last": true, "title": ["MRM-GRE法を用いた肝臓の鉄含有量および脂肪含有率の同時測定"], "weko_shared_id": -1}
MRM-GRE法を用いた肝臓の鉄含有量および脂肪含有率の同時測定
http://hdl.handle.net/2297/24703
http://hdl.handle.net/2297/247035c6b6233-cbf8-44d9-8da9-df4b913e514b
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MIYATI-T-64.pdf (731.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | MRM-GRE法を用いた肝臓の鉄含有量および脂肪含有率の同時測定 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Simultaneous R2* and Fat Fraction Determination of the Liver with Modulus and Real Multiple Gradient-echo MRI | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
小野, 絵理
× 小野, 絵理× 宮地, 利明× 大野, 直樹× 笠井, 治昌× 原, 真咲× 芝本, 雄太× 川野, 誠× 朝日, 美幸 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
医用画像情報学会雑誌 = Japan Society of Imaging and Information Sciences in Medicine 巻 26, 号 3, p. 64-67, 発行日 2009-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-1543 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10156808 | |||||
出版者 | ||||||
出版者 | 医用画象情報学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated the R2* (iron content) and fat fraction of the liver tissue simultaneously using modulus and real multiple gradient-echo (MRM-GRE) sequence. On a 1.5-T MRI, modulus images of 7-9 gradient-echoes were obtained by MRM-GRE sequence at a time. A real part of the first echo image was also reconstructed to differentiate below and above the 50 percent fat fraction. The fat fraction and R2* were obtained from the parameters of a theoretically fitted formula with each echo signal. R2* and fat fraction were measured with MRM-GRE in the phantom and the liver in normal volunteers (n=6) and patients with fatty liver (n=4) . MRI-derived fat fraction of the phantom was in good agreement with the actual value, and R2* of the phantom showed a strongly positive correlation with the actual iron content. MRI-derived fat fraction in fatty liver was significantly higher than that in the normal volunteers. However, no significant difference in R2* was found between fatty liver and normal volunteers. These results show that the MRM-GRE enables to differentiate the causes of signal reduction whether increasing R2*or increasing fat fraction. The MRM-GRE method makes it possible to simply and accurately assess the fat content and the iron content. | |||||
権利 | ||||||
権利情報 | Copyright (c) 2009 by Japan Society of Medical Imaging and Information Sciences | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.mii-sci.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/130000138572 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jstage.jst.go.jp/article/mii/26/3/26_64/_article |