WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "bcdb20ac-f0da-4517-b92e-8985d5ac311b"}, "_deposit": {"created_by": 3, "id": "13448", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13448"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013448", "sets": ["1134"]}, "author_link": ["22075", "22077", "22076", "22078", "20109"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1980-06-18", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "164", "bibliographicPageStart": "157", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "The Japanese Journal of Rehabilitation Medicine = リハビリテーション医学"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "1) The spinal evoked potentials (S.E.P.) obtained from the spinous processes are very much similar with the potential which are obtained from the epidural space. 2) The initial negative deflection corresponding to the action potentials of the dorsolateral tracts of spinal cord, and the second to those of the dorsal tracts was confirmed by the animal experiments. 3) The relationship between intensity and duration of the cord distraction trauma was explored in cats. The etiology of cord damage by distraction is probably due to ischemia. 4) In one patient who had an incomplete spinal cord injury, the S.E.P. has disappeared during correction of the kyphoscoliosis with a Harrington Distraction Rod, however with the partial release of distraction, it recovered immediately. In another patient with supposedly complete injury at C_5 level incompleteness was actually proved with the examination of the spinal evoked potentials. In two incomplete cord injuries at C_4 and C_6 injuries respectively, a nearly normal S.E.P. was recorded. In the case of complete quadriplegic patients, the S.E.P. was not recorded at all the level above lesion. 5) As the results of our study, we are certain that the S.E.P. which is obtained from K-wire inserted into the spinous processes can be safely and easily used for the examination of spinal cord function in various clinical situation. The gained data was also highly reliable.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Japanese Association of Rehabilitation Medicine = 日本リハビリテーション医学会"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jarm.or.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110001856922/en/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "本文データは日本リハビリテーション医学会の許諾に基づきCiNiiから複製したものである"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00250275", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-351X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "立野, 勝彦"}], "nameIdentifiers": [{"nameIdentifier": "20109", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40092788", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40092788"}, {"nameIdentifier": "40092788", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040092788"}]}, {"creatorNames": [{"creatorName": "馬場, 久敏"}], "nameIdentifiers": [{"nameIdentifier": "22075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "湯上, 博"}], "nameIdentifiers": [{"nameIdentifier": "22076", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Valencia, Pablo"}], "nameIdentifiers": [{"nameIdentifier": "22077", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mckinley, Laurence"}], "nameIdentifiers": [{"nameIdentifier": "22078", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-TACHINO-K-157.pdf", "filesize": [{"value": "876.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 876000.0, "url": {"label": "ME-PR-TACHINO-K-157.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13448/files/ME-PR-TACHINO-K-157.pdf"}, "version_id": "5e39303b-9ed3-4029-b939-90cdb6286f24"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "脊椎棘突起誘導による誘発脊髄電位の実験的研究及び脊髄損傷患者への臨床応用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "脊椎棘突起誘導による誘発脊髄電位の実験的研究及び脊髄損傷患者への臨床応用"}, {"subitem_title": "The spinal eoked potentials conducted from the spinous processes", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/23595", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13448", "relation": {}, "relation_version_is_last": true, "title": ["脊椎棘突起誘導による誘発脊髄電位の実験的研究及び脊髄損傷患者への臨床応用"], "weko_shared_id": -1}
脊椎棘突起誘導による誘発脊髄電位の実験的研究及び脊髄損傷患者への臨床応用
http://hdl.handle.net/2297/23595
http://hdl.handle.net/2297/235957e1dce5b-00da-4b5b-ab94-646f6ac98339
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-TACHINO-K-157.pdf (876.0 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 脊椎棘突起誘導による誘発脊髄電位の実験的研究及び脊髄損傷患者への臨床応用 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | The spinal eoked potentials conducted from the spinous processes | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
立野, 勝彦
× 立野, 勝彦× 馬場, 久敏× 湯上, 博× Valencia, Pablo× Mckinley, Laurence |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
The Japanese Journal of Rehabilitation Medicine = リハビリテーション医学 巻 17, 号 3, p. 157-164, 発行日 1980-06-18 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-351X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00250275 | |||||
出版者 | ||||||
出版者 | The Japanese Association of Rehabilitation Medicine = 日本リハビリテーション医学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 1) The spinal evoked potentials (S.E.P.) obtained from the spinous processes are very much similar with the potential which are obtained from the epidural space. 2) The initial negative deflection corresponding to the action potentials of the dorsolateral tracts of spinal cord, and the second to those of the dorsal tracts was confirmed by the animal experiments. 3) The relationship between intensity and duration of the cord distraction trauma was explored in cats. The etiology of cord damage by distraction is probably due to ischemia. 4) In one patient who had an incomplete spinal cord injury, the S.E.P. has disappeared during correction of the kyphoscoliosis with a Harrington Distraction Rod, however with the partial release of distraction, it recovered immediately. In another patient with supposedly complete injury at C_5 level incompleteness was actually proved with the examination of the spinal evoked potentials. In two incomplete cord injuries at C_4 and C_6 injuries respectively, a nearly normal S.E.P. was recorded. In the case of complete quadriplegic patients, the S.E.P. was not recorded at all the level above lesion. 5) As the results of our study, we are certain that the S.E.P. which is obtained from K-wire inserted into the spinous processes can be safely and easily used for the examination of spinal cord function in various clinical situation. The gained data was also highly reliable. | |||||
権利 | ||||||
権利情報 | 本文データは日本リハビリテーション医学会の許諾に基づきCiNiiから複製したものである | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jarm.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110001856922/en/ |