WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "c512463b-c55b-4915-8d99-6f08681173ff"}, "_deposit": {"created_by": 3, "id": "13974", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13974"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013974", "sets": ["1134"]}, "author_link": ["21834", "21831", "116", "538", "23656", "199", "23657"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "SUPPL. 1", "bibliographicPageEnd": "63", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "Interventional Neuroradiology"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purposes of this study are, firstly, to define the relationship between volume embolization ratio (VER) and degree of angiographical occlusion in endovascular treatment with Guglielmi detachable coils, and secondly, to examine influences of neck and dome sizes of aneurysms on the VER and the angiographical treatment result, and thirdly, to determine the relationship between the VER and the recanalization of coiled aneurysms. Fifty-two aneurysms in 46 patients were examined. VER ranged 8.1-31.9% (mean 18.5%). The mean VERs of each categories based on angiographical treatment results were 23.1% in complete occlusion, 16.1% in neck remnant and 12.2% in incomplete occlusion, respectively. The VER correlated significantly with both neck and dome size, while the angiographical treatment result was only affected by neck size. Five aneurysms showed aneurysmal recanalization among followed-up 41 aneurysms. All recanalized aneurysms were large, and their VERs were in range of 10.4-17.6%. Measurement of VER is useful to estimate the degree of occlusion objectively and to predict the aneurysmal recanalization. A small aneurysms with a small neck is relatively easy to achieve high VER and angiographical complete occlusion, with the consequence of less recanalization. On the other hand, a large aneurysm is liable to recanalize due to low VER, even if there was little filling of contrast medium in the aneurysmal cavity.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Japanese Society for Intravascular Neosurgery / Centauro srl"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1177/15910199000060s106", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1591-0199", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Uchiyama, Naoyuki"}], "nameIdentifiers": [{"nameIdentifier": "538", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80293364"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80293364"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080293364"}]}, {"creatorNames": [{"creatorName": "Kida, Shinya"}], "nameIdentifiers": [{"nameIdentifier": "23656", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nomura, Motohiro"}], "nameIdentifiers": [{"nameIdentifier": "23657", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Mitsuhiro"}], "nameIdentifiers": [{"nameIdentifier": "21831", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70218460", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70218460"}, {"nameIdentifier": "70218460", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070218460"}]}, {"creatorNames": [{"creatorName": "Yamashima, Tetsumori"}], "nameIdentifiers": [{"nameIdentifier": "199", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60135077", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60135077"}, {"nameIdentifier": "60135077", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060135077"}]}, {"creatorNames": [{"creatorName": "Yamashita, Junkoh"}], "nameIdentifiers": [{"nameIdentifier": "21834", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90026948", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90026948"}, {"nameIdentifier": "90026948", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090026948"}]}, {"creatorNames": [{"creatorName": "Matsui, Osamu"}], "nameIdentifiers": [{"nameIdentifier": "116", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10019961", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10019961"}, {"nameIdentifier": "10019961", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010019961"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-YAMASHIMA-T-59.pdf", "filesize": [{"value": "9.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 9600000.0, "url": {"label": "ME-PR-YAMASHIMA-T-59.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13974/files/ME-PR-YAMASHIMA-T-59.pdf"}, "version_id": "b8fa3fbe-cf82-4a4b-89ae-969e51300843"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Cerebral aneurysm", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Guglielmi detachable coil", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Recanalization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Volume embolization ratio", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/40390", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13974", "relation": {}, "relation_version_is_last": true, "title": ["Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils"], "weko_shared_id": 3}
Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils
http://hdl.handle.net/2297/40390
http://hdl.handle.net/2297/4039088fbc2af-17ed-4a15-b729-3609156aadad
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-YAMASHIMA-T-59.pdf (9.6 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Uchiyama, Naoyuki
× Uchiyama, Naoyuki× Kida, Shinya× Nomura, Motohiro× Hasegawa, Mitsuhiro× Yamashima, Tetsumori× Yamashita, Junkoh× Matsui, Osamu |
|||||
書誌情報 |
Interventional Neuroradiology 巻 6, 号 SUPPL. 1, p. 59-63, 発行日 2000-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1591-0199 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1177/15910199000060s106 | |||||
出版者 | ||||||
出版者 | Japanese Society for Intravascular Neosurgery / Centauro srl | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purposes of this study are, firstly, to define the relationship between volume embolization ratio (VER) and degree of angiographical occlusion in endovascular treatment with Guglielmi detachable coils, and secondly, to examine influences of neck and dome sizes of aneurysms on the VER and the angiographical treatment result, and thirdly, to determine the relationship between the VER and the recanalization of coiled aneurysms. Fifty-two aneurysms in 46 patients were examined. VER ranged 8.1-31.9% (mean 18.5%). The mean VERs of each categories based on angiographical treatment results were 23.1% in complete occlusion, 16.1% in neck remnant and 12.2% in incomplete occlusion, respectively. The VER correlated significantly with both neck and dome size, while the angiographical treatment result was only affected by neck size. Five aneurysms showed aneurysmal recanalization among followed-up 41 aneurysms. All recanalized aneurysms were large, and their VERs were in range of 10.4-17.6%. Measurement of VER is useful to estimate the degree of occlusion objectively and to predict the aneurysmal recanalization. A small aneurysms with a small neck is relatively easy to achieve high VER and angiographical complete occlusion, with the consequence of less recanalization. On the other hand, a large aneurysm is liable to recanalize due to low VER, even if there was little filling of contrast medium in the aneurysmal cavity. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |