{"_buckets": {"deposit": "bcbd36e2-7da4-404a-84a2-5b5ca577a69a"}, "_deposit": {"created_by": 3, "id": "14338", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14338"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014338", "sets": ["1134"]}, "author_link": ["24779", "24777", "529", "24778", "24776"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-03-18", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "941520", "bibliographicVolumeNumber": "9415", "bibliographic_titles": [{"bibliographic_title": "SPIE Proceedings"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We propose a new metric, local uncertainty (LU), for the evaluation of deformable image registration (DIR) for dose accumulation in radiotherapy. LU measures the uncertainty of placement of each voxel in an image set after a DIR. The underlying concept of LU is that the distance between a focused voxel and a surrounding voxel on an image feature such as an edge is unchanged locally when the organ that includes these voxels is deformed. A candidate for the focused voxel after DIR can be calculated from three surrounding voxels and their distances. The positions of the candidates of the focused voxel calculated from several groups of any three surrounding voxels would vary. The variation of candidate positions indicates uncertainty of the focused voxel position. Thus, the standard deviation of candidate positions is treated as an LU value. The LU can be calculated in uniform signal regions. Assessment of DIR results in such regions is important for dose accumulation. The LU calculation was applied to a pair of computed tomography (CT) head and neck examinations after DIR. These CT examinations were for the initial radiotherapy planning and re-planning for a treatment course where the tumor underwent shrinkage during treatment. We generated an LU image showing high LU values in the shrinking tumor region and low LU values in undeformable bone. We have proposed the LU as a new metric for DIR.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "SPIE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1117/12.2081846", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE)."}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takemura, Akihiro"}], "nameIdentifiers": [{"nameIdentifier": "529", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70313674"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70313674"}, {"nameIdentifier": "70313674", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070313674"}]}, {"creatorNames": [{"creatorName": "Kojima, Hironori"}], "nameIdentifiers": [{"nameIdentifier": "24776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueda, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "24777", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Isomura, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "24778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noto, Kimiya"}], "nameIdentifiers": [{"nameIdentifier": "24779", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-TAKEMURA-A-2014.pdf", "filesize": [{"value": "215.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 215000.0, "url": {"label": "ME-PR-TAKEMURA-A-2014.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14338/files/ME-PR-TAKEMURA-A-2014.pdf"}, "version_id": "1e214f0b-3047-4cdf-8c35-d62373b59c9a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Deformable Image Registration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Validation/Evaluation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Image-Guided Therapy", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A metric for evaluation of deformable image registration", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A metric for evaluation of deformable image registration"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/42224", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14338", "relation": {}, "relation_version_is_last": true, "title": ["A metric for evaluation of deformable image registration"], "weko_shared_id": -1}
A metric for evaluation of deformable image registration
http://hdl.handle.net/2297/42224
http://hdl.handle.net/2297/4222495d1f81c-c7ac-413d-8366-aae71e174d4a
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-TAKEMURA-A-2014.pdf (215.0 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | A metric for evaluation of deformable image registration | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Takemura, Akihiro
× Takemura, Akihiro× Kojima, Hironori× Ueda, Shinichi× Isomura, Naoki× Noto, Kimiya |
|||||
書誌情報 |
SPIE Proceedings 巻 9415, p. 941520, 発行日 2015-03-18 |
|||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1117/12.2081846 | |||||
出版者 | ||||||
出版者 | SPIE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We propose a new metric, local uncertainty (LU), for the evaluation of deformable image registration (DIR) for dose accumulation in radiotherapy. LU measures the uncertainty of placement of each voxel in an image set after a DIR. The underlying concept of LU is that the distance between a focused voxel and a surrounding voxel on an image feature such as an edge is unchanged locally when the organ that includes these voxels is deformed. A candidate for the focused voxel after DIR can be calculated from three surrounding voxels and their distances. The positions of the candidates of the focused voxel calculated from several groups of any three surrounding voxels would vary. The variation of candidate positions indicates uncertainty of the focused voxel position. Thus, the standard deviation of candidate positions is treated as an LU value. The LU can be calculated in uniform signal regions. Assessment of DIR results in such regions is important for dose accumulation. The LU calculation was applied to a pair of computed tomography (CT) head and neck examinations after DIR. These CT examinations were for the initial radiotherapy planning and re-planning for a treatment course where the tumor underwent shrinkage during treatment. We generated an LU image showing high LU values in the shrinking tumor region and low LU values in undeformable bone. We have proposed the LU as a new metric for DIR. | |||||