WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "55246191-fc08-433c-81ea-c03f7af57e4e"}, "_deposit": {"created_by": 3, "id": "14499", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14499"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014499", "sets": ["1134"]}, "author_link": ["1328", "599", "25446", "264", "320", "489", "25448", "115", "25447", "1413"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "68", "bibliographicPageStart": "60", "bibliographicVolumeNumber": "28", "bibliographic_titles": [{"bibliographic_title": "Annals of Nuclear Medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objective: The aim of this study was to characterize the optimal reconstruction parameters for ordered-subset expectation maximization (OSEM) with attenuation correction, scatter correction, and depth-dependent resolution recovery (OSEMACSCRR). We assessed the optimal parameters for OSEMACSCRR in an anthropomorphic torso phantom study, and evaluated the validity of the reconstruction parameters in the groups of normal volunteers and patients with abnormal perfusion. Methods: Images of the anthropomorphic torso phantom, 9 normal volunteers and 7 patients undergoing myocardial perfusion SPECT were acquired with a SPECT/CT scanner. SPECT data comprised a 64 × 64 matrix with an acquisition pixel size of 6.6 mm. A normalized mean square error (NMSE) of the phantom image was calculated to determine both optimal OSEM update and a full width at half maximum (FWHM) of Gaussian filter. We validated the myocardial count, contrast and noise characteristic for clinical subjects derived from OSEMACSCRR processing. OSEM with depth-dependent resolution recovery (OSEMRR) and filtered back projection (FBP) were simultaneously performed to compare OSEMACSCRR. Results: The combination of OSEMACSCRR with 90-120 OSEM updates and Gaussian filter with 13.2-14.85 mm FWHM yielded low NMSE value in the phantom study. When we used OSEMACSCRR with 120 updates and Gaussian filter with 13.2 mm FWHM in the normal volunteers, myocardial contrast showed significantly higher value than that derived from 120 updates and 14.85 mm FWHM. OSEMACSCRR with the combination of 90-120 OSEM updates and 14.85 mm FWHM produced lowest % root mean square (RMS) noise. Regarding the defect contrast of patients with abnormal perfusion, OSEMACSCRR with the combination of 90-120 OSEM updates and 13.2 mm FWHM produced significantly higher value than that derived from 90-120 OSEM updates and 14.85 mm FWHM. OSEMACSCRR was superior to FBP for the % RMS noise (8.52 ± 1.08 vs. 9.55 ± 1.71, p = 0.02) and defect contrast (0.368 ± 0.061 vs. 0.327 ± 0.052, p = 0.01), respectively. Conclusions: Clinically optimized the number of OSEM updates and FWHM of Gaussian filter were (1) 120 updates and 13.2 mm, and (2) 90-120 updates and 14.85 mm on the OSEMACSCRR processing, respectively. Further assessment may be required to determine the optimal iterative reconstruction parameters in a larger patient population. © 2013 The Japanese Society of Nuclear Medicine.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Japanese Society of Nuclear Medicine 日本核医学会 / Springer Verlag (Germany)"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12149-013-0785-6", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsnm.org/", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10708017", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-7187", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Okuda, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "25446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "320", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000000167545"}]}, {"creatorNames": [{"creatorName": "Yamada, Masato"}], "nameIdentifiers": [{"nameIdentifier": "25447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakabayashi, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "489", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60622818", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60622818"}, {"nameIdentifier": "60622818", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060622818"}]}, {"creatorNames": [{"creatorName": "Ichikawa, Hajime"}], "nameIdentifiers": [{"nameIdentifier": "1328", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60303939", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60303939"}, {"nameIdentifier": "60303939", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060303939"}]}, {"creatorNames": [{"creatorName": "Arai, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "25448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuo, Shinro"}], "nameIdentifiers": [{"nameIdentifier": "599", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30359773"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030359773"}]}, {"creatorNames": [{"creatorName": "Taki, Junichi"}], "nameIdentifiers": [{"nameIdentifier": "264", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00167545"}, {"nameIdentifier": "10251927", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10251927"}, {"nameIdentifier": "10251927", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010251927"}]}, {"creatorNames": [{"creatorName": "Hashimoto, Mitsumasa"}], "nameIdentifiers": [{"nameIdentifier": "1413", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70293975", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70293975"}, {"nameIdentifier": "70293975", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070293975"}]}, {"creatorNames": [{"creatorName": "Kinuya, Seigo"}], "nameIdentifiers": [{"nameIdentifier": "115", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20281024"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=20281024"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020281024"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-NAKAJIMA-K-60.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "ME-PR-NAKAJIMA-K-60.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14499/files/ME-PR-NAKAJIMA-K-60.pdf"}, "version_id": "42d3fbfb-6832-4efe-ba47-60026a142987"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Attenuation correction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Depth-dependent resolution recovery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Myocardial perfusion SPECT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ordered-subset expectation maximization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Scatter correction", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/36500", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14499", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT"], "weko_shared_id": 3}
Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT
http://hdl.handle.net/2297/36500
http://hdl.handle.net/2297/36500af307214-5136-46ee-be13-19abe777af1b
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-NAKAJIMA-K-60.pdf (1.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Okuda, Koichi
× Okuda, Koichi× Nakajima, Kenichi× Yamada, Masato× Wakabayashi, Hiroshi× Ichikawa, Hajime× Arai, Hiroyuki× Matsuo, Shinro× Taki, Junichi× Hashimoto, Mitsumasa× Kinuya, Seigo |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 28, 号 1, p. 60-68, 発行日 2014-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10708017 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-013-0785-6 | |||||
出版者 | ||||||
出版者 | Japanese Society of Nuclear Medicine 日本核医学会 / Springer Verlag (Germany) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: The aim of this study was to characterize the optimal reconstruction parameters for ordered-subset expectation maximization (OSEM) with attenuation correction, scatter correction, and depth-dependent resolution recovery (OSEMACSCRR). We assessed the optimal parameters for OSEMACSCRR in an anthropomorphic torso phantom study, and evaluated the validity of the reconstruction parameters in the groups of normal volunteers and patients with abnormal perfusion. Methods: Images of the anthropomorphic torso phantom, 9 normal volunteers and 7 patients undergoing myocardial perfusion SPECT were acquired with a SPECT/CT scanner. SPECT data comprised a 64 × 64 matrix with an acquisition pixel size of 6.6 mm. A normalized mean square error (NMSE) of the phantom image was calculated to determine both optimal OSEM update and a full width at half maximum (FWHM) of Gaussian filter. We validated the myocardial count, contrast and noise characteristic for clinical subjects derived from OSEMACSCRR processing. OSEM with depth-dependent resolution recovery (OSEMRR) and filtered back projection (FBP) were simultaneously performed to compare OSEMACSCRR. Results: The combination of OSEMACSCRR with 90-120 OSEM updates and Gaussian filter with 13.2-14.85 mm FWHM yielded low NMSE value in the phantom study. When we used OSEMACSCRR with 120 updates and Gaussian filter with 13.2 mm FWHM in the normal volunteers, myocardial contrast showed significantly higher value than that derived from 120 updates and 14.85 mm FWHM. OSEMACSCRR with the combination of 90-120 OSEM updates and 14.85 mm FWHM produced lowest % root mean square (RMS) noise. Regarding the defect contrast of patients with abnormal perfusion, OSEMACSCRR with the combination of 90-120 OSEM updates and 13.2 mm FWHM produced significantly higher value than that derived from 90-120 OSEM updates and 14.85 mm FWHM. OSEMACSCRR was superior to FBP for the % RMS noise (8.52 ± 1.08 vs. 9.55 ± 1.71, p = 0.02) and defect contrast (0.368 ± 0.061 vs. 0.327 ± 0.052, p = 0.01), respectively. Conclusions: Clinically optimized the number of OSEM updates and FWHM of Gaussian filter were (1) 120 updates and 13.2 mm, and (2) 90-120 updates and 14.85 mm on the OSEMACSCRR processing, respectively. Further assessment may be required to determine the optimal iterative reconstruction parameters in a larger patient population. © 2013 The Japanese Society of Nuclear Medicine. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsnm.org/ |