WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "aa5e334d-f0ac-421b-88a4-7fb7d0fd5e03"}, "_deposit": {"created_by": 3, "id": "14584", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14584"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014584", "sets": ["1134"]}, "author_link": ["25794", "25795", "140", "223", "25793"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "65", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "8", "bibliographic_titles": [{"bibliographic_title": "形態・機能 = Structure and function "}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "我々は、三角筋筋肉内注射部位に関する解剖体を用いて、腋窩神経損傷を避けるために、同神経の位置を体表面から相対的に決定する方法を明らかにした。その方法を用いて、14 名の被験者において腋窩神経が走行すると推定した部位で後上腕回旋動脈の血流音を超音波血流検知器を用いて聴取し、さらに同じ部位でデジタル超音波診断装置画像を撮影し後上腕回旋動脈が確認されるかを検討した。その結果、先行研究における腋窩神経走行部位の相対的な決定方法が生体にも応用可能であること、また、超音波血流検知器を用いて後上腕回旋動脈の血流音を確認することによって腋窩神経走行部位をより確実に決定できることが示唆された。In our previous studies, we determined the course of the axillary nerve in cadavers and projected these finings on the skin covering the deltoid muscle. Since the posterior humeral circumflex artery runs anatomically along the nerve, in the present study, we examined whether this information could be useful to facilitate detection of the axillary nerve living bodies by detecting the blood flow of the artery using a handhold ultrasound blood flowmeter and ultrasound diagnostic equipment. As a result, the sound of blood flow and the image of the artery were demonstrated adjacent to the course of the axillary nerve, although it was difficult to directly visualize the axillary nerve by this method. This indicates that the method of determining the course of the axillary nerve in a cadaver can be adapted to the living body as well. To ascertain the course of the axillary nerve, it is useful to identify the course of the posterior humeral circumflex artery using an ultrasound blood flowmeter and ultrasound diagnostic equipment.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "コ・メディカル形態機能学研究会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12137631", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-7145", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "原, 由里子"}], "nameIdentifiers": [{"nameIdentifier": "25793", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒川, 佳奈"}], "nameIdentifiers": [{"nameIdentifier": "25794", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浦井, 珠恵"}], "nameIdentifiers": [{"nameIdentifier": "25795", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大桑, 麻由美"}], "nameIdentifiers": [{"nameIdentifier": "140", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30303291", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30303291"}, {"nameIdentifier": "30303291", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30303291"}, {"nameIdentifier": "30303291", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030303291"}]}, {"creatorNames": [{"creatorName": "中谷, 壽男"}], "nameIdentifiers": [{"nameIdentifier": "223", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60198124", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60198124"}, {"nameIdentifier": "60198124", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060198124"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-NAKATANI-T-59.pdf", "filesize": [{"value": "379.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 379900.0, "url": {"label": "ME-PR-NAKATANI-T-59.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14584/files/ME-PR-NAKATANI-T-59.pdf"}, "version_id": "b7280937-be22-48bc-92fa-9ddd0cdc7eb7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "腋窩神経", "subitem_subject_scheme": "Other"}, {"subitem_subject": "後上腕回旋動脈", "subitem_subject_scheme": "Other"}, {"subitem_subject": "三角筋", "subitem_subject_scheme": "Other"}, {"subitem_subject": "筋肉内注射", "subitem_subject_scheme": "Other"}, {"subitem_subject": "axillary nerve", "subitem_subject_scheme": "Other"}, {"subitem_subject": "posterior humeral circumflex artery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "deltoid muscle", "subitem_subject_scheme": "Other"}, {"subitem_subject": "intramuscular injection", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "筋肉内注射で重要な生体の腋窩神経走行推定のために,後上腕回旋動脈を超音波血流検知器およびデジタル超音波診断装置で測定することの有効性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "筋肉内注射で重要な生体の腋窩神経走行推定のために,後上腕回旋動脈を超音波血流検知器およびデジタル超音波診断装置で測定することの有効性"}, {"subitem_title": "To determine the course of the axillary nerve, it is useful to identify the course of the posterior humeral circumflex artery that runs along the nerve using a handheld ultrasound blood flowmeter and ultrasound diagnostic equipment", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/24249", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14584", "relation": {}, "relation_version_is_last": true, "title": ["筋肉内注射で重要な生体の腋窩神経走行推定のために,後上腕回旋動脈を超音波血流検知器およびデジタル超音波診断装置で測定することの有効性"], "weko_shared_id": -1}
筋肉内注射で重要な生体の腋窩神経走行推定のために,後上腕回旋動脈を超音波血流検知器およびデジタル超音波診断装置で測定することの有効性
http://hdl.handle.net/2297/24249
http://hdl.handle.net/2297/242490f77fc0e-2d38-43e9-a691-5b4ae14e4dde
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-NAKATANI-T-59.pdf (379.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 筋肉内注射で重要な生体の腋窩神経走行推定のために,後上腕回旋動脈を超音波血流検知器およびデジタル超音波診断装置で測定することの有効性 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | To determine the course of the axillary nerve, it is useful to identify the course of the posterior humeral circumflex artery that runs along the nerve using a handheld ultrasound blood flowmeter and ultrasound diagnostic equipment | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
原, 由里子
× 原, 由里子× 黒川, 佳奈× 浦井, 珠恵× 大桑, 麻由美× 中谷, 壽男 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
形態・機能 = Structure and function 巻 8, 号 2, p. 59-65, 発行日 2010-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-7145 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12137631 | |||||
出版者 | ||||||
出版者 | コ・メディカル形態機能学研究会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 我々は、三角筋筋肉内注射部位に関する解剖体を用いて、腋窩神経損傷を避けるために、同神経の位置を体表面から相対的に決定する方法を明らかにした。その方法を用いて、14 名の被験者において腋窩神経が走行すると推定した部位で後上腕回旋動脈の血流音を超音波血流検知器を用いて聴取し、さらに同じ部位でデジタル超音波診断装置画像を撮影し後上腕回旋動脈が確認されるかを検討した。その結果、先行研究における腋窩神経走行部位の相対的な決定方法が生体にも応用可能であること、また、超音波血流検知器を用いて後上腕回旋動脈の血流音を確認することによって腋窩神経走行部位をより確実に決定できることが示唆された。In our previous studies, we determined the course of the axillary nerve in cadavers and projected these finings on the skin covering the deltoid muscle. Since the posterior humeral circumflex artery runs anatomically along the nerve, in the present study, we examined whether this information could be useful to facilitate detection of the axillary nerve living bodies by detecting the blood flow of the artery using a handhold ultrasound blood flowmeter and ultrasound diagnostic equipment. As a result, the sound of blood flow and the image of the artery were demonstrated adjacent to the course of the axillary nerve, although it was difficult to directly visualize the axillary nerve by this method. This indicates that the method of determining the course of the axillary nerve in a cadaver can be adapted to the living body as well. To ascertain the course of the axillary nerve, it is useful to identify the course of the posterior humeral circumflex artery using an ultrasound blood flowmeter and ultrasound diagnostic equipment. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |