WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "222f4f7e-cd7b-4fec-aaa3-aafd648f76f0"}, "_deposit": {"created_by": 3, "id": "14736", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14736"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014736", "sets": ["4312"]}, "author_link": ["69263", "21479", "299", "26282", "21236", "21578", "116", "85235", "20090", "71925", "21296", "91300", "297", "21480", "13121"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-06-20", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "737", "bibliographicPageStart": "728", "bibliographicVolumeNumber": "65", "bibliographic_titles": [{"bibliographic_title": "Japanese journal of Radiological Technology = 日本放射線技術學會誌 / Nippon Hoshasen Gijutsu Gakkai zasshi"}]}]}, "item_4_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tanaka, Rie"}], "nameIdentifiers": [{"nameIdentifier": "85235", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40361985"}]}, {"creatorNames": [{"creatorName": "Sanada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "91300", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50020029"}]}, {"creatorNames": [{"creatorName": "Fujimura, Masaki"}], "nameIdentifiers": [{"nameIdentifier": "71925", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90190066", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90190066"}]}, {"creatorNames": [{"creatorName": "Yasui, Masahide"}], "nameIdentifiers": [{"nameIdentifier": "21236", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60239746", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60239746"}]}, {"creatorNames": [{"creatorName": "Tsuji, Shiro"}], "nameIdentifiers": [{"nameIdentifier": "20090", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70227388", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070227388"}]}, {"creatorNames": [{"creatorName": "Hayashi, Norio"}], "nameIdentifiers": [{"nameIdentifier": "21479", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nanbu, Yuko"}], "nameIdentifiers": [{"nameIdentifier": "21480", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsui, Osamu"}], "nameIdentifiers": [{"nameIdentifier": "69263", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10019961", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10019961"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Pulmonary ventilation and circulation dynamics are reflected on dynamic chest radiographs as changes in X-ray translucency,i.e., pixel values. The present study was performed to develop a pulmonary functional evaluation method based on the changes in pixel value, and to investigate the clinical usefulness of our method. Sequential chest radiographs of 20 subjects (abnormal,n=12; normal,n=8) during respiration were obtained with a dynamic flat-panel detector (FPD) system. The average pixel value in each local area was measured tracking the same area. To facilitate visual evaluation, the results were mapped on the original image using a grayscale in which small changes were shown in black and large changes were shown in white. In our clinical evaluation in comparison with a pulmonary scintigraphy, pulmonary ventilation disorder was indicated as a reduction of changes in pixel values. In many patients, there was a correlation between our result and a pulmonary scintigraphy (0.7\u003cr, 4 cases; 0.4\u003cr\u003cor=0.7, 6 cases; 0.2\u003cr\u003cor=0.4, 1 case; 0\u003cr\u003cor=0.2, 1 case). The present method with real-time computer analysis is expected to be a rapid and simple method for evaluating pulmonary function and as an additional examination in conventional chest radiography.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_4_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00014723", "subitem_identifier_reg_type": "JaLC"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本放射線技術学会 = JSRT : Japanese Society of Radiological Technology"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jstage.jst.go.jp/article/jjrt/65/6/728/_pdf", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00197784", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0369-4305", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田中, 利恵"}], "nameIdentifiers": [{"nameIdentifier": "299", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040361985"}]}, {"creatorNames": [{"creatorName": "真田, 茂"}], "nameIdentifiers": [{"nameIdentifier": "13121", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50020029"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050020029"}]}, {"creatorNames": [{"creatorName": "藤村, 政樹"}], "nameIdentifiers": [{"nameIdentifier": "297", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90190066", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90190066"}, {"nameIdentifier": "90190066", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090190066"}]}, {"creatorNames": [{"creatorName": "安井, 正英"}], "nameIdentifiers": [{"nameIdentifier": "21296", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60239746", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060239746"}]}, {"creatorNames": [{"creatorName": "辻, 志郎"}], "nameIdentifiers": [{"nameIdentifier": "20090", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70227388", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070227388"}]}, {"creatorNames": [{"creatorName": "林, 則夫"}], "nameIdentifiers": [{"nameIdentifier": "21578", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "南部, 裕子"}], "nameIdentifiers": [{"nameIdentifier": "26282", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松井, 修"}], "nameIdentifiers": [{"nameIdentifier": "116", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10019961", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10019961"}, {"nameIdentifier": "10019961", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010019961"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-TANAKA-R-728.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "ME-PR-TANAKA-R-728.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14736/files/ME-PR-TANAKA-R-728.pdf"}, "version_id": "23bffe54-92e9-4ebe-846d-2dd750ef225b"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "動画対応フラットパネルディテクタによる肺機能画像診断法 : 肺シンチグラフィ所見との比較", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "動画対応フラットパネルディテクタによる肺機能画像診断法 : 肺シンチグラフィ所見との比較"}, {"subitem_title": "Pulmonary functional diagnostic imaging using a dynamic flat-panel detector: comparison with findings in pulmonary scintigraphy", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["4312"], "permalink_uri": "https://doi.org/10.24517/00014723", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14736", "relation": {}, "relation_version_is_last": true, "title": ["動画対応フラットパネルディテクタによる肺機能画像診断法 : 肺シンチグラフィ所見との比較"], "weko_shared_id": 3}
動画対応フラットパネルディテクタによる肺機能画像診断法 : 肺シンチグラフィ所見との比較
https://doi.org/10.24517/00014723
https://doi.org/10.24517/00014723bc1dfe7e-2583-439a-a04c-a5182d00ae88
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-TANAKA-R-728.pdf (1.0 MB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 動画対応フラットパネルディテクタによる肺機能画像診断法 : 肺シンチグラフィ所見との比較 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Pulmonary functional diagnostic imaging using a dynamic flat-panel detector: comparison with findings in pulmonary scintigraphy | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.24517/00014723 | |||||
ID登録タイプ | JaLC | |||||
著者 |
田中, 利恵
× 田中, 利恵× 真田, 茂× 藤村, 政樹× 安井, 正英× 辻, 志郎× 林, 則夫× 南部, 裕子× 松井, 修 |
|||||
著者別表示 |
Tanaka, Rie
× Tanaka, Rie× Sanada, Shigeru× Fujimura, Masaki× Yasui, Masahide× Tsuji, Shiro× Hayashi, Norio× Nanbu, Yuko× Matsui, Osamu |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
Japanese journal of Radiological Technology = 日本放射線技術學會誌 / Nippon Hoshasen Gijutsu Gakkai zasshi 巻 65, 号 6, p. 728-737, 発行日 2009-06-20 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0369-4305 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00197784 | |||||
出版者 | ||||||
出版者 | 日本放射線技術学会 = JSRT : Japanese Society of Radiological Technology | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Pulmonary ventilation and circulation dynamics are reflected on dynamic chest radiographs as changes in X-ray translucency,i.e., pixel values. The present study was performed to develop a pulmonary functional evaluation method based on the changes in pixel value, and to investigate the clinical usefulness of our method. Sequential chest radiographs of 20 subjects (abnormal,n=12; normal,n=8) during respiration were obtained with a dynamic flat-panel detector (FPD) system. The average pixel value in each local area was measured tracking the same area. To facilitate visual evaluation, the results were mapped on the original image using a grayscale in which small changes were shown in black and large changes were shown in white. In our clinical evaluation in comparison with a pulmonary scintigraphy, pulmonary ventilation disorder was indicated as a reduction of changes in pixel values. In many patients, there was a correlation between our result and a pulmonary scintigraphy (0.7<r, 4 cases; 0.4<r<or=0.7, 6 cases; 0.2<r<or=0.4, 1 case; 0<r<or=0.2, 1 case). The present method with real-time computer analysis is expected to be a rapid and simple method for evaluating pulmonary function and as an additional examination in conventional chest radiography. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jstage.jst.go.jp/article/jjrt/65/6/728/_pdf |