WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "4fa9ed2d-687f-451e-ab71-8353319086c0"}, "_deposit": {"created_by": 3, "id": "29430", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "29430"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00029430", "sets": ["1981"]}, "author_link": ["50766", "50763", "11069", "50765", "50764", "11068"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-12-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "508", "bibliographicPageStart": "503", "bibliographicVolumeNumber": "9", "bibliographic_titles": [{"bibliographic_title": "日本AEM学会誌"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The repulsive type magnetic bearing system, which has the passive control utilizing the repulsive forces and active control along axial direction, is superior compared to other magnetic bearings in respect to reduce the number of peripheral devices. The repulsive type magnetic bearing has special features such as the soft and constant stiffness for passive control axes. Hence this system can be applied for a special device without impulse disturbance and mechanical contact for the levitator shaft. In this paper we make a proposition to apply to a thermobalance using the repulsive type magnetic levitation system. If our system can be applied, the accuracy of measurement and sensitivity will be high owing to null mechanical contacts of the levitator. This paper reports the configuration and noncontact levitation characteristics of the trial manufacture and introduces the differential thermobalance configuration made as a next plan.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本AEM学会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大路, 貴久"}], "nameIdentifiers": [{"nameIdentifier": "50763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "東, 剛人"}], "nameIdentifiers": [{"nameIdentifier": "50764", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60308179", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60308179"}, {"nameIdentifier": "60308179", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060308179"}]}, {"creatorNames": [{"creatorName": "井上, 裕章"}], "nameIdentifiers": [{"nameIdentifier": "50765", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 外史"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}, {"creatorNames": [{"creatorName": "岩原, 正吉"}], "nameIdentifiers": [{"nameIdentifier": "11068", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80020212", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080020212"}]}, {"creatorNames": [{"creatorName": "高田, 義博"}], "nameIdentifiers": [{"nameIdentifier": "50766", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-503.pdf", "filesize": [{"value": "488.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 488200.0, "url": {"label": "TE-PR-YAMADA-S-503.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/29430/files/TE-PR-YAMADA-S-503.pdf"}, "version_id": "bff6a1c5-5586-4094-b7e7-916a19919fe7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Magnetic levitation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "permanent magnet", "subitem_subject_scheme": "Other"}, {"subitem_subject": "repulsive force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "stiffness", "subitem_subject_scheme": "Other"}, {"subitem_subject": "thermobalance", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "永久磁石反発を用いた磁気浮上天秤の試作", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "永久磁石反発を用いた磁気浮上天秤の試作"}, {"subitem_title": "Trial manufacture of the repulsive type balance magnetic levitation system using permanent magnets", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1981"], "permalink_uri": "http://hdl.handle.net/2297/11799", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-05"}, "publish_date": "2017-10-05", "publish_status": "0", "recid": "29430", "relation": {}, "relation_version_is_last": true, "title": ["永久磁石反発を用いた磁気浮上天秤の試作"], "weko_shared_id": -1}
永久磁石反発を用いた磁気浮上天秤の試作
http://hdl.handle.net/2297/11799
http://hdl.handle.net/2297/1179997309e8c-07a5-4934-a90c-0901c2c2ece3
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-503.pdf (488.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-05 | |||||
タイトル | ||||||
タイトル | 永久磁石反発を用いた磁気浮上天秤の試作 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Trial manufacture of the repulsive type balance magnetic levitation system using permanent magnets | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
大路, 貴久
× 大路, 貴久× 東, 剛人× 井上, 裕章× 山田, 外史× 岩原, 正吉× 高田, 義博 |
|||||
書誌情報 |
日本AEM学会誌 巻 9, 号 4, p. 503-508, 発行日 2001-12-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0919-4452 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10457520 | |||||
出版者 | ||||||
出版者 | 日本AEM学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The repulsive type magnetic bearing system, which has the passive control utilizing the repulsive forces and active control along axial direction, is superior compared to other magnetic bearings in respect to reduce the number of peripheral devices. The repulsive type magnetic bearing has special features such as the soft and constant stiffness for passive control axes. Hence this system can be applied for a special device without impulse disturbance and mechanical contact for the levitator shaft. In this paper we make a proposition to apply to a thermobalance using the repulsive type magnetic levitation system. If our system can be applied, the accuracy of measurement and sensitivity will be high owing to null mechanical contacts of the levitator. This paper reports the configuration and noncontact levitation characteristics of the trial manufacture and introduces the differential thermobalance configuration made as a next plan. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |