{"_buckets": {"deposit": "1e6bdc3e-e0af-422f-a64a-62ba7e65f095"}, "_deposit": {"created_by": 18, "id": "44445", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "44445"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00044445", "sets": ["2816"]}, "author_link": ["73956", "521"], "item_9_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-05-18", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "6p.", "bibliographicVolumeNumber": "2015-04-01 - 2018-03-31", "bibliographic_titles": [{"bibliographic_title": "平成29(2017)年度 科学研究費補助金 基盤研究(C) 研究成果報告書"}, {"bibliographic_title": "2017 Fiscal Year Final Research Report", "bibliographic_titleLang": "en"}]}]}, "item_9_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsubara, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "73956", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30507372"}]}]}, "item_9_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "i本研究では,新しい概念を有するCT装置であるdual-source CT,area-detector CTにおける線量・エネルギー評価法を考案し,その精度を確認した.Dual-source CT装置に関しては,小型線量計の線量値補正法,簡易的半価層測定法,高速撮影時における小型線量計を用いた線量測定法を構築した.Area-detector CT装置に関しては,線量評価のために用いる線量計の最適化を行った.", "subitem_description_type": "Abstract"}, {"subitem_description": "In this study, radiation dose and energy evaluation methods for dual-source and area-detector CT, which have new concepts, was devised, and their accuracy was confirmed. In dual-source CT, the methods for correcting dose values of small dosimeters, easily evaluating half-value layer, and dose measurement for high-pitch acquisition by using small dosimeters were constructed. In area-detector CT, the optimization of dosimeter used for evaluating radiation dose was conducted.", "subitem_description_type": "Abstract"}]}, "item_9_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "研究課題/領域番号:15K09887, 研究期間(年度):2015-04-01 - 2018-03-31", "subitem_description_type": "Other"}, {"subitem_description": "出典:研究課題「新しい概念を有するX線CT装置の線量・エネルギー評価法の確立」課題番号15K09887\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所)) \n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/)を加工して作成", "subitem_description_type": "Other"}]}, "item_9_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00050787", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/search/?qm=30507372"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/search/?qm=30507372", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K09887/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K09887/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/", "subitem_relation_type_select": "URI"}}]}, "item_9_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松原, 孝祐"}], "nameIdentifiers": [{"nameIdentifier": "521", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30507372"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030507372"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-04-12"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MATSUBARA-K-kaken 2018-6p.pdf", "filesize": [{"value": "645.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 645300.0, "url": {"label": "ME-PR-MATSUBARA-K-kaken 2018-6p.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/44445/files/ME-PR-MATSUBARA-K-kaken 2018-6p.pdf"}, "version_id": "6922c563-9831-4c58-a86a-c2804e162272"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "X線", "subitem_subject_scheme": "Other"}, {"subitem_subject": "コンピュータ断層撮影", "subitem_subject_scheme": "Other"}, {"subitem_subject": "被ばく", "subitem_subject_scheme": "Other"}, {"subitem_subject": "線量", "subitem_subject_scheme": "Other"}, {"subitem_subject": "エネルギー", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "新しい概念を有するX線CT装置の線量・エネルギー評価法の確立", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "新しい概念を有するX線CT装置の線量・エネルギー評価法の確立"}, {"subitem_title": "Establishment of radiation dose and energy evaluation methods for X-ray computed tomography having new concepts", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "18", "path": ["2816"], "permalink_uri": "https://doi.org/10.24517/00050787", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-04-12"}, "publish_date": "2019-04-12", "publish_status": "0", "recid": "44445", "relation": {}, "relation_version_is_last": true, "title": ["新しい概念を有するX線CT装置の線量・エネルギー評価法の確立"], "weko_shared_id": -1}
新しい概念を有するX線CT装置の線量・エネルギー評価法の確立
https://doi.org/10.24517/00050787
https://doi.org/10.24517/00050787ee9e9fb6-5abf-4902-96de-bc2e8fd078ac
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MATSUBARA-K-kaken 2018-6p.pdf (645.3 kB)
|
Item type | 報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-04-12 | |||||
タイトル | ||||||
タイトル | 新しい概念を有するX線CT装置の線量・エネルギー評価法の確立 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Establishment of radiation dose and energy evaluation methods for X-ray computed tomography having new concepts | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
ID登録 | ||||||
ID登録 | 10.24517/00050787 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松原, 孝祐
× 松原, 孝祐 |
|||||
著者別表示 |
Matsubara, Kosuke
× Matsubara, Kosuke |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
平成29(2017)年度 科学研究費補助金 基盤研究(C) 研究成果報告書 en : 2017 Fiscal Year Final Research Report 巻 2015-04-01 - 2018-03-31, p. 6p., 発行日 2018-05-18 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | i本研究では,新しい概念を有するCT装置であるdual-source CT,area-detector CTにおける線量・エネルギー評価法を考案し,その精度を確認した.Dual-source CT装置に関しては,小型線量計の線量値補正法,簡易的半価層測定法,高速撮影時における小型線量計を用いた線量測定法を構築した.Area-detector CT装置に関しては,線量評価のために用いる線量計の最適化を行った. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, radiation dose and energy evaluation methods for dual-source and area-detector CT, which have new concepts, was devised, and their accuracy was confirmed. In dual-source CT, the methods for correcting dose values of small dosimeters, easily evaluating half-value layer, and dose measurement for high-pitch acquisition by using small dosimeters were constructed. In area-detector CT, the optimization of dosimeter used for evaluating radiation dose was conducted. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 研究課題/領域番号:15K09887, 研究期間(年度):2015-04-01 - 2018-03-31 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 出典:研究課題「新しい概念を有するX線CT装置の線量・エネルギー評価法の確立」課題番号15K09887 (KAKEN:科学研究費助成事業データベース(国立情報学研究所)) (https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/)を加工して作成 |
|||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/search/?qm=30507372 | |||||
関連名称 | https://kaken.nii.ac.jp/search/?qm=30507372 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K09887/ | |||||
関連名称 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-15K09887/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/ | |||||
関連名称 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-15K09887/15K09887seika/ |