WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "c8752297-81b4-4a5b-9ad4-06f2356b73f5"}, "_deposit": {"created_by": 18, "id": "44447", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "44447"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00044447", "sets": ["2823"]}, "author_link": ["73956", "521"], "item_9_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-05-23", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "6p.", "bibliographicVolumeNumber": "2009-2010", "bibliographic_titles": [{"bibliographic_title": "平成22(2010)年度 科学研究費補助金 若手研究(B) 研究成果報告書"}, {"bibliographic_title": "2010 Fiscal Year Final Research Report", "bibliographic_titleLang": "en"}]}]}, "item_9_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsubara, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "73956", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30507372"}]}]}, "item_9_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ECG同期冠動脈CTAを施行する場合であっても,撮影法,心拍数によって胸部臓器の吸収線量は大きく異なることが確認された.BEIR VII Phase 2 reportより推定した肺がんの発生リスクは,ECG同期高速二重螺旋スキャン法では0.006%,ECG同期非螺旋スキャン法では0.034%,ECG同期螺旋スキャン法では0.073%であった.ECG同期冠動脈CTAを施行する際には,それぞれの撮影方式は適切に選択されるべきであり,ECG同期高速二重螺旋スキャン法では,画質の劣化を伴うことへのリスクも注意深く考慮する必要がある.", "subitem_description_type": "Abstract"}, {"subitem_description": "It was confirmed that radiation doses absorbed by thoracic organs during ECG-gated coronary CTA were different according to the acquisition technique and heart rate. The estimated lifetime attributable risks of lung cancer incidence in patients who underwent ECG-gated coronary CTA were 0.006% with the ECG-gated high-pitch dual-spiral mode, 0.034% with the ECG-gated step-and-shoot mode, and 0.073% with the ECG-gated low-pitch spiral mode, respectively. Each acquisition mode should be selected appropriately, and it is necessary to carefully consider the risk for deterioration of image quality when the ECG-gated high-pitch dual-spiral mode is applied.", "subitem_description_type": "Abstract"}]}, "item_9_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "出典:研究課題「ECG 同期冠動脈 CTAにおける臓器吸収線量の評価」課題番号21791175\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所)) \n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/)を加工して作成", "subitem_description_type": "Other"}]}, "item_9_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医薬保健研究域保健学系", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00050789", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/search/?qm=30507372"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/search/?qm=30507372", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-21791175/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-21791175/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/", "subitem_relation_type_select": "URI"}}]}, "item_9_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松原, 孝祐"}], "nameIdentifiers": [{"nameIdentifier": "521", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30507372"}, {"nameIdentifier": "30507372", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030507372"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-05-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MATSUBARA-K-kaken 2012-6p.pdf", "filesize": [{"value": "846.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 846700.0, "url": {"label": "ME-PR-MATSUBARA-K-kaken 2012-6p.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/44447/files/ME-PR-MATSUBARA-K-kaken 2012-6p.pdf"}, "version_id": "38b1a977-f465-4ae3-b890-34e365480cfd"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "エックス線", "subitem_subject_scheme": "Other"}, {"subitem_subject": "CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "被ばく", "subitem_subject_scheme": "Other"}, {"subitem_subject": "冠動脈", "subitem_subject_scheme": "Other"}, {"subitem_subject": "吸収線量", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "ECG 同期冠動脈 CTAにおける臓器吸収線量の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ECG 同期冠動脈 CTAにおける臓器吸収線量の評価"}, {"subitem_title": "Evaluation of organ-absorbed dose in ECG-gated coronary CTA", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "18", "path": ["2823"], "permalink_uri": "https://doi.org/10.24517/00050789", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-05-21"}, "publish_date": "2018-05-21", "publish_status": "0", "recid": "44447", "relation": {}, "relation_version_is_last": true, "title": ["ECG 同期冠動脈 CTAにおける臓器吸収線量の評価"], "weko_shared_id": -1}
ECG 同期冠動脈 CTAにおける臓器吸収線量の評価
https://doi.org/10.24517/00050789
https://doi.org/10.24517/0005078971b82d77-0699-4771-bae5-5f3e5a3b7204
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MATSUBARA-K-kaken 2012-6p.pdf (846.7 kB)
|
Item type | 報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-05-21 | |||||
タイトル | ||||||
タイトル | ECG 同期冠動脈 CTAにおける臓器吸収線量の評価 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Evaluation of organ-absorbed dose in ECG-gated coronary CTA | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
ID登録 | ||||||
ID登録 | 10.24517/00050789 | |||||
ID登録タイプ | JaLC | |||||
著者別表示 |
Matsubara, Kosuke
× Matsubara, Kosuke |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
平成22(2010)年度 科学研究費補助金 若手研究(B) 研究成果報告書 en : 2010 Fiscal Year Final Research Report 巻 2009-2010, p. 6p., 発行日 2012-05-23 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ECG同期冠動脈CTAを施行する場合であっても,撮影法,心拍数によって胸部臓器の吸収線量は大きく異なることが確認された.BEIR VII Phase 2 reportより推定した肺がんの発生リスクは,ECG同期高速二重螺旋スキャン法では0.006%,ECG同期非螺旋スキャン法では0.034%,ECG同期螺旋スキャン法では0.073%であった.ECG同期冠動脈CTAを施行する際には,それぞれの撮影方式は適切に選択されるべきであり,ECG同期高速二重螺旋スキャン法では,画質の劣化を伴うことへのリスクも注意深く考慮する必要がある. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | It was confirmed that radiation doses absorbed by thoracic organs during ECG-gated coronary CTA were different according to the acquisition technique and heart rate. The estimated lifetime attributable risks of lung cancer incidence in patients who underwent ECG-gated coronary CTA were 0.006% with the ECG-gated high-pitch dual-spiral mode, 0.034% with the ECG-gated step-and-shoot mode, and 0.073% with the ECG-gated low-pitch spiral mode, respectively. Each acquisition mode should be selected appropriately, and it is necessary to carefully consider the risk for deterioration of image quality when the ECG-gated high-pitch dual-spiral mode is applied. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 出典:研究課題「ECG 同期冠動脈 CTAにおける臓器吸収線量の評価」課題番号21791175 (KAKEN:科学研究費助成事業データベース(国立情報学研究所)) (https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/)を加工して作成 |
|||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/search/?qm=30507372 | |||||
関連名称 | https://kaken.nii.ac.jp/search/?qm=30507372 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-21791175/ | |||||
関連名称 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-21791175/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/ | |||||
関連名称 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-21791175/21791175seika/ |