WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "ecf06ec4-fa2f-4a89-82a4-c14558ee8569"}, "_deposit": {"created_by": 3, "id": "695", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "695"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00000695", "sets": ["16"]}, "author_link": ["3606", "3609", "168", "3608", "3610", "3607"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-08-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "500", "bibliographicPageStart": "493", "bibliographicVolumeNumber": "48", "bibliographic_titles": [{"bibliographic_title": "体力科学 = Japanese journal of physical fitness and sports medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The evaluation of muscular power function has been mainly limited to dynamic contraction, but force-time parameters in static explosive contraction may be useful. The purpose of this study was to examine the trial-to-trial differences of exertion pattern and the reliability of the force-time parameters in the development phase of static maximal explosive grip (SEG) using seventy healthy young male subjects (age 18.8±2.3yr) . In SEG measurement, subjects were instructed to exert maximal isometric force with a dominant hand as fast and forcefully as possible. Data was collected from two trials with 3 minutes rest between trials. Eleven variables (time to fixed level, average force, integrated area, maximal rate of force development, and equivalent for mechanical power parameter) were selected as force-time parameters. The reliability of maximal grip strength (MAX) was very high (ICC=0.944, p\u003c0.05) . In the above-stated instruction condition, the trial-to-trial difference expanded from 0.1- 0.4 sec, then re-duced in the vicinity of MAX during SEG exertion. Significant differences, however, were not found at any exertion time and reproducibility of SEG exertion pattern was very high between the two trials. The trial-to-trial reliability in all force-time parameters was significant (ICC=0.346-0.878, p\u003c0.05) . Reliability of the parameters measuring the earlier phase (about 0.1-0.5 sec) was low or moderate (ICC\u003c0.7), while reliability of the parameters measuring the MAX vicinity tended to be high. The MAX relationship to force-time parameters in the MAX vicinity is high, but is low or moderate for the other parameters. It was suggested that the force-time parameters in the vicinity of MAX in SEG exertion might be useful for evaluating static power function in a clinical setting.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本体力医学会 = Japanese Society of Physical Fitness and Sports Medicine"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jspfsm.umin.ne.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.journalarchive.jst.go.jp/japanese/jnlabstract_ja.php?cdjournal=jspfsm1949\u0026cdvol=48\u0026noissue=4\u0026startpage=493", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © by Japanese Society of Physical Fitness and Sports Medicine"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00137986", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0039-906X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "出村, 慎一"}], "nameIdentifiers": [{"nameIdentifier": "168", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20155485"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020155485"}]}, {"creatorNames": [{"creatorName": "山次, 俊介"}], "nameIdentifiers": [{"nameIdentifier": "3606", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "南, 雅樹"}], "nameIdentifiers": [{"nameIdentifier": "3607", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長澤, 吉則"}], "nameIdentifiers": [{"nameIdentifier": "3608", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北, 一郎"}], "nameIdentifiers": [{"nameIdentifier": "3609", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松澤, 甚三郎"}], "nameIdentifiers": [{"nameIdentifier": "3610", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ED-PR-DEMURA-S-435.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "ED-PR-DEMURA-S-435.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/695/files/ED-PR-DEMURA-S-435.pdf"}, "version_id": "a02eb9b8-8bba-4088-8edb-3e9a27bf8ab6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "force-time parameter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "static explosive grip", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reliability", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "静的瞬発握力発揮時の増張力局面における発揮パターンの再現性と力 : 時間変数の信頼性の検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "静的瞬発握力発揮時の増張力局面における発揮パターンの再現性と力 : 時間変数の信頼性の検討"}, {"subitem_title": "Examining reproducibilty of force-exertion pattern and reliability of force-time parameters in the development phase during static explosive grip exertion", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["16"], "permalink_uri": "http://hdl.handle.net/2297/29427", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-02"}, "publish_date": "2017-10-02", "publish_status": "0", "recid": "695", "relation": {}, "relation_version_is_last": true, "title": ["静的瞬発握力発揮時の増張力局面における発揮パターンの再現性と力 : 時間変数の信頼性の検討"], "weko_shared_id": -1}
静的瞬発握力発揮時の増張力局面における発揮パターンの再現性と力 : 時間変数の信頼性の検討
http://hdl.handle.net/2297/29427
http://hdl.handle.net/2297/29427cbfdc1fb-badc-4e1e-8c9d-2015cd168580
名前 / ファイル | ライセンス | アクション |
---|---|---|
ED-PR-DEMURA-S-435.pdf (1.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-02 | |||||
タイトル | ||||||
タイトル | 静的瞬発握力発揮時の増張力局面における発揮パターンの再現性と力 : 時間変数の信頼性の検討 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Examining reproducibilty of force-exertion pattern and reliability of force-time parameters in the development phase during static explosive grip exertion | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
出村, 慎一
× 出村, 慎一× 山次, 俊介× 南, 雅樹× 長澤, 吉則× 北, 一郎× 松澤, 甚三郎 |
|||||
書誌情報 |
体力科学 = Japanese journal of physical fitness and sports medicine 巻 48, 号 4, p. 493-500, 発行日 1999-08-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0039-906X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00137986 | |||||
出版者 | ||||||
出版者 | 日本体力医学会 = Japanese Society of Physical Fitness and Sports Medicine | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The evaluation of muscular power function has been mainly limited to dynamic contraction, but force-time parameters in static explosive contraction may be useful. The purpose of this study was to examine the trial-to-trial differences of exertion pattern and the reliability of the force-time parameters in the development phase of static maximal explosive grip (SEG) using seventy healthy young male subjects (age 18.8±2.3yr) . In SEG measurement, subjects were instructed to exert maximal isometric force with a dominant hand as fast and forcefully as possible. Data was collected from two trials with 3 minutes rest between trials. Eleven variables (time to fixed level, average force, integrated area, maximal rate of force development, and equivalent for mechanical power parameter) were selected as force-time parameters. The reliability of maximal grip strength (MAX) was very high (ICC=0.944, p<0.05) . In the above-stated instruction condition, the trial-to-trial difference expanded from 0.1- 0.4 sec, then re-duced in the vicinity of MAX during SEG exertion. Significant differences, however, were not found at any exertion time and reproducibility of SEG exertion pattern was very high between the two trials. The trial-to-trial reliability in all force-time parameters was significant (ICC=0.346-0.878, p<0.05) . Reliability of the parameters measuring the earlier phase (about 0.1-0.5 sec) was low or moderate (ICC<0.7), while reliability of the parameters measuring the MAX vicinity tended to be high. The MAX relationship to force-time parameters in the MAX vicinity is high, but is low or moderate for the other parameters. It was suggested that the force-time parameters in the vicinity of MAX in SEG exertion might be useful for evaluating static power function in a clinical setting. | |||||
権利 | ||||||
権利情報 | Copyright © by Japanese Society of Physical Fitness and Sports Medicine | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jspfsm.umin.ne.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.journalarchive.jst.go.jp/japanese/jnlabstract_ja.php?cdjournal=jspfsm1949&cdvol=48&noissue=4&startpage=493 |