WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "3954fc11-044c-46f3-9b0b-2f4043a5b8a2"}, "_deposit": {"created_by": 3, "id": "7727", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "7727"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00007727", "sets": ["936"]}, "author_link": ["10448", "42", "10447", "10449"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "37", "bibliographicPageStart": "32", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "Engineering in Medicine and Biology Magazine, IEEE"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/MEMB.2005.1463393", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_30": {"attribute_name": "親アイテム(IsPartOf)", "attribute_value_mlt": [{"subitem_relation_type": "isPartOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://hdl.handle.net/2297/9285", "subitem_relation_type_select": "URI"}}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tanaka, S."}], "nameIdentifiers": [{"nameIdentifier": "10447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Gao, Shumei"}], "nameIdentifiers": [{"nameIdentifier": "10448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nogawa, M."}], "nameIdentifiers": [{"nameIdentifier": "10449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "42", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40014310"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040014310"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "preparation.txt", "filesize": [{"value": "71 Bytes"}], "format": "text/plain", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "text/plain", "size": 0.0, "url": {"label": "preparation.txt", "url": "https://kanazawa-u.repo.nii.ac.jp/record/7727/files/preparation.txt"}, "version_id": "66eeff0c-2b0c-4da0-9067-a4f073e0da30"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Noninvasive measurement of instantaneous, radial artery blood pressure", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Noninvasive measurement of instantaneous, radial artery blood pressure"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/9537", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "7727", "relation": {}, "relation_version_is_last": true, "title": ["Noninvasive measurement of instantaneous, radial artery blood pressure"], "weko_shared_id": -1}
Noninvasive measurement of instantaneous, radial artery blood pressure
http://hdl.handle.net/2297/9537
http://hdl.handle.net/2297/9537237b2fe1-e88a-47d4-94ff-92349ba099b1
名前 / ファイル | ライセンス | アクション |
---|---|---|
preparation.txt (71 Bytes)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Noninvasive measurement of instantaneous, radial artery blood pressure | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tanaka, S.
× Tanaka, S.× Gao, Shumei× Nogawa, M.× Yamakoshi, Kenichi |
|||||
書誌情報 |
Engineering in Medicine and Biology Magazine, IEEE 巻 24, 号 4, p. 32-37, 発行日 2005-01-01 |
|||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/MEMB.2005.1463393 | |||||
出版者 | ||||||
出版者 | IEEE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
親アイテム(IsPartOf) | ||||||
関連タイプ | isPartOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://hdl.handle.net/2297/9285 |