WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "638175fe-98bd-456f-ba8d-206a7c0e9e3b"}, "_deposit": {"created_by": 3, "id": "8987", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "8987"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00008987", "sets": ["936"]}, "author_link": ["12769", "12770", "12768", "12771", "10974", "11933", "42"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "35", "bibliographicPageStart": "28", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "IEEE Journal of Biomedical and Health Informatics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We explored the potential of health screening based on the long-term measurement of cardiovascular parameters using the finger volume-oscillometric technique. An automated instrument made simultaneous measurements of key cardiovascular parameters, including blood pressure, pulse pressure, heart rate, normalized pulse volume as an index of α-adrenalin-mediated sympathetic activity, and finger arterial elasticity. These were derived from finger photo-plethysmographic signals during application of cuff pressure. To assess the feasibility of achieving a screening function, measurements were made in ten healthy volunteers during 10 days of day-to-day living (normal condition), and carried out several times at a fixed time every day. During successive 10-day measurements, a 30-hour period of total sleep deprivation was introduced as a physiological challenge (abnormal condition). A linear discriminant analysis of the data was conducted to determine whether these two conditions could be discriminated. Periodic data collection was performed rapidly and easily, and the %-correct classifications of normal and abnormal conditions were 78.2% and 77.5%, respectively. This ability of the method to discriminate between regular and sleep-deprived activities demonstrates its potential for healthcare screening during day-to-day living. Further investigations using larger age and gender groups of subjects including patients with cardiovascular diseases under real-life situations are required. © 2013 IEEE.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/JBHI.2013.2274460", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_27": {"attribute_name": "シリーズ", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "6566041"}]}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2168-2194", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamakoshi, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "10974", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070444205"}]}, {"creatorNames": [{"creatorName": "Matsumura, Kenta"}], "nameIdentifiers": [{"nameIdentifier": "11933", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30510383", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30510383"}, {"nameIdentifier": "30510383", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030510383"}]}, {"creatorNames": [{"creatorName": "Rolfe, Peter"}], "nameIdentifiers": [{"nameIdentifier": "12768", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hanaki, Shota"}], "nameIdentifiers": [{"nameIdentifier": "12769", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikarashi, Akira"}], "nameIdentifiers": [{"nameIdentifier": "12770", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Lee, Jihyoung"}], "nameIdentifiers": [{"nameIdentifier": "12771", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Ken-ichi"}], "nameIdentifiers": [{"nameIdentifier": "42", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40014310"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040014310"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMAKOSHI-T-28.pdf", "filesize": [{"value": "906.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 906400.0, "url": {"label": "TE-PR-YAMAKOSHI-T-28.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/8987/files/TE-PR-YAMAKOSHI-T-28.pdf"}, "version_id": "c4f07b53-c370-469f-b69c-654151adf826"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Blood pressure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Finger-artery elasticity index", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Healthcare", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Heart rate", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Normalized pulse volume", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pulse pressure", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/36900", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "8987", "relation": {}, "relation_version_is_last": true, "title": ["Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities"], "weko_shared_id": -1}
Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities
http://hdl.handle.net/2297/36900
http://hdl.handle.net/2297/369008e6fb39e-cc77-43d1-8ae4-878da7d4a0b3
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMAKOSHI-T-28.pdf (906.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Yamakoshi, Takehiro
× Yamakoshi, Takehiro× Matsumura, Kenta× Rolfe, Peter× Hanaki, Shota× Ikarashi, Akira× Lee, Jihyoung× Yamakoshi, Ken-ichi |
|||||
書誌情報 |
IEEE Journal of Biomedical and Health Informatics 巻 18, 号 1, p. 28-35, 発行日 2014-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2168-2194 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/JBHI.2013.2274460 | |||||
出版者 | ||||||
出版者 | IEEE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We explored the potential of health screening based on the long-term measurement of cardiovascular parameters using the finger volume-oscillometric technique. An automated instrument made simultaneous measurements of key cardiovascular parameters, including blood pressure, pulse pressure, heart rate, normalized pulse volume as an index of α-adrenalin-mediated sympathetic activity, and finger arterial elasticity. These were derived from finger photo-plethysmographic signals during application of cuff pressure. To assess the feasibility of achieving a screening function, measurements were made in ten healthy volunteers during 10 days of day-to-day living (normal condition), and carried out several times at a fixed time every day. During successive 10-day measurements, a 30-hour period of total sleep deprivation was introduced as a physiological challenge (abnormal condition). A linear discriminant analysis of the data was conducted to determine whether these two conditions could be discriminated. Periodic data collection was performed rapidly and easily, and the %-correct classifications of normal and abnormal conditions were 78.2% and 77.5%, respectively. This ability of the method to discriminate between regular and sleep-deprived activities demonstrates its potential for healthcare screening during day-to-day living. Further investigations using larger age and gender groups of subjects including patients with cardiovascular diseases under real-life situations are required. © 2013 IEEE. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
シリーズ | ||||||
関連名称 | 6566041 |