WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "c1011691-649e-4bf9-8824-a25afc1886ff"}, "_deposit": {"created_by": 3, "id": "9282", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9282"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009282", "sets": ["936"]}, "author_link": ["327", "13307"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1992-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "246", "bibliographicPageStart": "237", "bibliographicVolumeNumber": "48", "bibliographic_titles": [{"bibliographic_title": "Journal of Agricultural Meteorology = 農業気象"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Having had imagined the heat recovery from exhaust air out of a compost bed, experiments for rising the temperature of water (medium fluid) by a packed column heating tower of counter flow-type were conducted. There was a considerably larger temperature rise of water (30°C of the maximun), and a higher value of the heat recovery efficiency (72% in average), as compared with those for the buried-tube-type heat extractor. Therefore, the proposed heat recovery system seemed likely to be valid. An overall volumetric coefficient of enthalpy transfer of the tower Ka depended only on the mass velocity of dry air G, and it was arranged by the experimental equation Ka=27G0.76 within the error of±20%. Assuming the linearity between the enthalpy and temperature of saturated air, approximate solutions of the temperature of water and the enthalpy of moist air in the tower were derived. It was illustrated that the volume of compost bed and the mass velocity of water in the tower which would be required to get the desired water temperature at the outlet of the tower could be graphically determined by the approximate solutions.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本農業気象学会 = Society of Agricultural Meteorology of Japan"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2480/agrmet.48.237", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/agrmet", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://agrmet.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © The Society of Agricultural Meteorology of Japan"}]}, "item_4_rights_24": {"attribute_name": "権利URI", "attribute_value_mlt": [{"subitem_rights": "http://www.agrmet.jp/"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12492451", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-8588", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "関, 平和"}], "nameIdentifiers": [{"nameIdentifier": "327", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90115246", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090115246"}]}, {"creatorNames": [{"creatorName": "小森, 友明"}], "nameIdentifiers": [{"nameIdentifier": "13307", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50019725", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50019725"}, {"nameIdentifier": "50019725", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050019725"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-SEKI-H-237.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "TE-PR-SEKI-H-237.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9282/files/TE-PR-SEKI-H-237.pdf"}, "version_id": "1bfa6ec3-f13c-46a7-a03f-afd13ae28c67"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "充填層型加熱塔", "subitem_subject_scheme": "Other"}, {"subitem_subject": "総括エンタルピー移動容量係数", "subitem_subject_scheme": "Other"}, {"subitem_subject": "堆肥化", "subitem_subject_scheme": "Other"}, {"subitem_subject": "熱回収", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Packed column heating tower", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Overall volumetric coefficient of enthalpy transfer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Composting", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Heat recovery", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "堆肥発酵熱回収のための充填層型加熱塔の解析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "堆肥発酵熱回収のための充填層型加熱塔の解析"}, {"subitem_title": "Packed-column-type Heating Tower for Recovery of Heat Generated in Compost", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/46801", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9282", "relation": {}, "relation_version_is_last": true, "title": ["堆肥発酵熱回収のための充填層型加熱塔の解析"], "weko_shared_id": -1}
堆肥発酵熱回収のための充填層型加熱塔の解析
http://hdl.handle.net/2297/46801
http://hdl.handle.net/2297/468012e103541-3649-44ba-9b98-9bb3dcd854ef
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-SEKI-H-237.pdf (1.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 堆肥発酵熱回収のための充填層型加熱塔の解析 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Packed-column-type Heating Tower for Recovery of Heat Generated in Compost | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
関, 平和
× 関, 平和× 小森, 友明 |
|||||
書誌情報 |
Journal of Agricultural Meteorology = 農業気象 巻 48, 号 3, p. 237-246, 発行日 1992-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0021-8588 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12492451 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2480/agrmet.48.237 | |||||
出版者 | ||||||
出版者 | 日本農業気象学会 = Society of Agricultural Meteorology of Japan | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Having had imagined the heat recovery from exhaust air out of a compost bed, experiments for rising the temperature of water (medium fluid) by a packed column heating tower of counter flow-type were conducted. There was a considerably larger temperature rise of water (30°C of the maximun), and a higher value of the heat recovery efficiency (72% in average), as compared with those for the buried-tube-type heat extractor. Therefore, the proposed heat recovery system seemed likely to be valid. An overall volumetric coefficient of enthalpy transfer of the tower Ka depended only on the mass velocity of dry air G, and it was arranged by the experimental equation Ka=27G0.76 within the error of±20%. Assuming the linearity between the enthalpy and temperature of saturated air, approximate solutions of the temperature of water and the enthalpy of moist air in the tower were derived. It was illustrated that the volume of compost bed and the mass velocity of water in the tower which would be required to get the desired water temperature at the outlet of the tower could be graphically determined by the approximate solutions. | |||||
権利 | ||||||
権利情報 | Copyright © The Society of Agricultural Meteorology of Japan | |||||
権利URI | ||||||
権利情報 | http://www.agrmet.jp/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/agrmet | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://agrmet.jp/ |