WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "993289e3-e662-4bef-8134-3812fbae91ec"}, "_deposit": {"created_by": 3, "id": "9546", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9546"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009546", "sets": ["936"]}, "author_link": ["11069", "13797", "13798", "189"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "2587", "bibliographicPageStart": "2584", "bibliographicVolumeNumber": "47", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Maggetics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The aim of this study is to present the novel methodology for magnetic markers immunoassay measurements by spin valve giant magnetoresistive (SV-GMR) needle probe. Extremely small size and specific construction of this probe type allow detecting the changes of complex susceptibility directly from the sample. The needle-type probe consists of four SV-GMR elements connected in a Wheatstone bridge and it has sensitivity of 11 V/ T. The SV-GMR sensing element has dimensions of 40 m 75 m. This paper presents a setup feasible to perform spectroscopic magnetic markers measurement. It includes data related to signal changes caused by the magnetic markers dilution. It shows the influence of particle size changes (120 nm, 1 m, 3.5 m, 6.5 m) on real and imaginary parts of the complex susceptibility of the specimen. While performing measurements, probe sensing elements were placed inside the sample. Monitoring changes of samples susceptibility allows performing homogenous immunoassay measurements in a liquid phase by SV-GMR probe. Based on the measurement results, analytical model of changes of complex susceptibility is derived and described.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electrical and Electronics Engineers IEEE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/tmag.2011.2157959", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00667933", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Haraszczuk, R."}], "nameIdentifiers": [{"nameIdentifier": "13797", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Sotoshi"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}, {"creatorNames": [{"creatorName": "Kakikawa, Makiko"}], "nameIdentifiers": [{"nameIdentifier": "189", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010359713"}]}, {"creatorNames": [{"creatorName": "Ueno, T"}], "nameIdentifiers": [{"nameIdentifier": "13798", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-311.pdf", "filesize": [{"value": "503.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 503700.0, "url": {"label": "TE-PR-YAMADA-S-311.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9546/files/TE-PR-YAMADA-S-311.pdf"}, "version_id": "f2bc1f14-8790-4ecd-8200-2cd7fda67626"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Biomarkers", "subitem_subject_scheme": "Other"}, {"subitem_subject": "giant magnetoresistance", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic susceptibility", "subitem_subject_scheme": "Other"}, {"subitem_subject": "nanoparticles", "subitem_subject_scheme": "Other"}, {"subitem_subject": "spin valves (SVs)", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Monitoring Minute chances of Magnetic Maekers\u0027 Susveptability by SV-GMR Needle-Type Probe", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Monitoring Minute chances of Magnetic Maekers\u0027 Susveptability by SV-GMR Needle-Type Probe"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/48351", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9546", "relation": {}, "relation_version_is_last": true, "title": ["Monitoring Minute chances of Magnetic Maekers\u0027 Susveptability by SV-GMR Needle-Type Probe"], "weko_shared_id": 3}
Monitoring Minute chances of Magnetic Maekers' Susveptability by SV-GMR Needle-Type Probe
http://hdl.handle.net/2297/48351
http://hdl.handle.net/2297/48351873506fe-5777-4622-9c62-4fd40cecdda2
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-311.pdf (503.7 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Monitoring Minute chances of Magnetic Maekers' Susveptability by SV-GMR Needle-Type Probe | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Haraszczuk, R.
× Haraszczuk, R.× Yamada, Sotoshi× Kakikawa, Makiko× Ueno, T |
|||||
書誌情報 |
IEEE Transactions on Maggetics 巻 47, 号 10, p. 2584-2587, 発行日 2011-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9464 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00667933 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/tmag.2011.2157959 | |||||
出版者 | ||||||
出版者 | Institute of Electrical and Electronics Engineers IEEE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The aim of this study is to present the novel methodology for magnetic markers immunoassay measurements by spin valve giant magnetoresistive (SV-GMR) needle probe. Extremely small size and specific construction of this probe type allow detecting the changes of complex susceptibility directly from the sample. The needle-type probe consists of four SV-GMR elements connected in a Wheatstone bridge and it has sensitivity of 11 V/ T. The SV-GMR sensing element has dimensions of 40 m 75 m. This paper presents a setup feasible to perform spectroscopic magnetic markers measurement. It includes data related to signal changes caused by the magnetic markers dilution. It shows the influence of particle size changes (120 nm, 1 m, 3.5 m, 6.5 m) on real and imaginary parts of the complex susceptibility of the specimen. While performing measurements, probe sensing elements were placed inside the sample. Monitoring changes of samples susceptibility allows performing homogenous immunoassay measurements in a liquid phase by SV-GMR probe. Based on the measurement results, analytical model of changes of complex susceptibility is derived and described. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |