{"_buckets": {"deposit": "fab87ee3-4da6-4f06-b91d-11a4be68205d"}, "_deposit": {"created_by": 3, "id": "9755", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9755"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009755", "sets": ["936"]}, "author_link": ["14240", "14242", "14239", "14241", "14238", "145"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-05-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "108", "bibliographicPageStart": "103", "bibliographicVolumeNumber": "98", "bibliographic_titles": [{"bibliographic_title": "Microchemical Journal"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Separation of trace levels of lead from concentrated-matrix electroless nickel plating (ENP) waste solutions is required to meet the increasingly stringent environmental regulations. A solid phase extraction (SPE) system using a molecular recognition technology (MRT) gel was used for the selective separation of trace levels of lead (Pb) from the waste discharge of ENP operations, followed by subsequent analysis with inductively coupled plasma optical emission spectrometry (ICP-OES). Two SPE-MRTs, AnaLig® Pb-01 and AnaLig® Pb-02, packed in 3 mL polypropylene cartridges were used to treat the synthetic metal-waste solutions that were used to simulate the typical metal mixture in ENP bath waste. The fortified solutions contained 100-1000 μg L- 1 of Pb in an HNO3 matrix with pre-added Ni, Cu and other interfering elements (1000 mg L- 1). After the sample treatment, the SPE-MRT cartridges were washed with water and 0.1 M nitric acid, followed by elution with 0.03 M EDTA. The matrix elements (e.g., Ni, Cu) were completely removed at the washing step, while the \u0027captured\u0027 Pb was quantitatively eluted, as determined by ICP-OES measurements. The detection limit of the proposed method was 2.6 μg L- 1. \u0027Real\u0027 samples from commercial ENP operations were used to assess the validity of this method, and almost quantitative Pb recovery was observed. The excellent Pb selectivity of the SPE-MRT system indicates the potential of the proposed technique for trace-level Pb separation from the Pb-containing high matrix aqueous waste discharge. © 2010 Elsevier B.V. All rights reserved.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学理工研究域物質化学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier BV"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.microc.2010.12.005", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.elsevier.com/locate/issn/0026265X", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00738394", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0026-265X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Rahman, Ismail M. M."}], "nameIdentifiers": [{"nameIdentifier": "14238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Furusho, Yoshiaki"}], "nameIdentifiers": [{"nameIdentifier": "14239", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Begum, Zinnat A."}], "nameIdentifiers": [{"nameIdentifier": "14240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ronald, Neil Izatt"}], "nameIdentifiers": [{"nameIdentifier": "14241", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akhmad Sabarudin, Bruening"}], "nameIdentifiers": [{"nameIdentifier": "14242", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hasegawa, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "145", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90253335"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=90253335"}, {"nameIdentifier": "90253335", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090253335"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-HASEGAWA-H-2011.pdf", "filesize": [{"value": "95.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 95200.0, "url": {"label": "TE-PR-HASEGAWA-H-2011.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9755/files/TE-PR-HASEGAWA-H-2011.pdf"}, "version_id": "83997e0a-7b33-4e86-adf5-deab3e0a0b94"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Electroless nickel plating solution", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ion-selective", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Lead separation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Molecular recognition technology", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Non-destructive", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Solid phase extraction", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Separation of lead from high matrix electroless nickel plating waste solution using an ion-selective immobilized macrocycle system", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Separation of lead from high matrix electroless nickel plating waste solution using an ion-selective immobilized macrocycle system"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/26264", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9755", "relation": {}, "relation_version_is_last": true, "title": ["Separation of lead from high matrix electroless nickel plating waste solution using an ion-selective immobilized macrocycle system"], "weko_shared_id": -1}
Separation of lead from high matrix electroless nickel plating waste solution using an ion-selective immobilized macrocycle system
http://hdl.handle.net/2297/26264
http://hdl.handle.net/2297/262641be51749-3e8c-4b06-b8fc-eac62afae814
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-HASEGAWA-H-2011.pdf (95.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Separation of lead from high matrix electroless nickel plating waste solution using an ion-selective immobilized macrocycle system | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Rahman, Ismail M. M.
× Rahman, Ismail M. M.× Furusho, Yoshiaki× Begum, Zinnat A.× Ronald, Neil Izatt× Akhmad Sabarudin, Bruening× Hasegawa, Hiroshi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学理工研究域物質化学系 | |||||
書誌情報 |
Microchemical Journal 巻 98, 号 1, p. 103-108, 発行日 2011-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0026-265X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00738394 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.microc.2010.12.005 | |||||
出版者 | ||||||
出版者 | Elsevier BV | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Separation of trace levels of lead from concentrated-matrix electroless nickel plating (ENP) waste solutions is required to meet the increasingly stringent environmental regulations. A solid phase extraction (SPE) system using a molecular recognition technology (MRT) gel was used for the selective separation of trace levels of lead (Pb) from the waste discharge of ENP operations, followed by subsequent analysis with inductively coupled plasma optical emission spectrometry (ICP-OES). Two SPE-MRTs, AnaLig® Pb-01 and AnaLig® Pb-02, packed in 3 mL polypropylene cartridges were used to treat the synthetic metal-waste solutions that were used to simulate the typical metal mixture in ENP bath waste. The fortified solutions contained 100-1000 μg L- 1 of Pb in an HNO3 matrix with pre-added Ni, Cu and other interfering elements (1000 mg L- 1). After the sample treatment, the SPE-MRT cartridges were washed with water and 0.1 M nitric acid, followed by elution with 0.03 M EDTA. The matrix elements (e.g., Ni, Cu) were completely removed at the washing step, while the 'captured' Pb was quantitatively eluted, as determined by ICP-OES measurements. The detection limit of the proposed method was 2.6 μg L- 1. 'Real' samples from commercial ENP operations were used to assess the validity of this method, and almost quantitative Pb recovery was observed. The excellent Pb selectivity of the SPE-MRT system indicates the potential of the proposed technique for trace-level Pb separation from the Pb-containing high matrix aqueous waste discharge. © 2010 Elsevier B.V. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/0026265X |