WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "2195a6a4-fe65-4fcc-8894-907125c4958f"}, "_deposit": {"created_by": 3, "id": "9796", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9796"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009796", "sets": ["936"]}, "author_link": ["14327", "14322", "12018", "14323", "14324", "14320", "14326", "42", "14321", "14325"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "145", "bibliographicPageStart": "142", "bibliographicVolumeNumber": "25 IFMBE", "bibliographic_titles": [{"bibliographic_title": "IFMBE Proceedings"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to evaluate the efficacy of rehabilitation for persons with hemiplegia, a therapist usually makes judgment by directly observing posture changes, walking speed, activities not only in hospital, but also during daily living. Therefore, quantitative assessment of activities is most desirable. From this viewpoint, we have developed a device for ambulatory monitoring of posture changes, walking speed and activity scenario and evaluated its measurement accuracy by simultaneous recordings of a digital video camera. In order to investigate its applicability to a patient\u0027s activity monitoring, we have further developed a new monitoring system which can display static and dynamic motion pictures as well as detailed angle changes of the trunk, thigh and calf. This system makes a therapist to easily understand the patient\u0027s motion during training in rehabilitation center and activities during daily living. By evaluation on 6 patients with hemiplegia, the patients\u0027 motions were successfully monitored during walking in the rehabilitation center and daily living at their own home. The results clearly demonstrated that the system could detect detailed motion characteristics, indicating that the system appears useful for evaluating quantitatively the efficacy of rehabilitation. © 2009 Springer-Verlag.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学理工研究域機械工学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Verlag"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/978-3-642-03889-1-39", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1680-0737", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Motoi, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "12018", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80422640", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080422640"}]}, {"creatorNames": [{"creatorName": "Kuwae, Yutaka"}], "nameIdentifiers": [{"nameIdentifier": "14320", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taniguchi, S."}], "nameIdentifiers": [{"nameIdentifier": "14321", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakugawa, M."}], "nameIdentifiers": [{"nameIdentifier": "14322", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yuji, Tadahiko"}], "nameIdentifiers": [{"nameIdentifier": "14323", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higashi, Y."}], "nameIdentifiers": [{"nameIdentifier": "14324", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujimoto, T."}], "nameIdentifiers": [{"nameIdentifier": "14325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ogawa, M."}], "nameIdentifiers": [{"nameIdentifier": "14326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, S."}], "nameIdentifiers": [{"nameIdentifier": "14327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "42", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40014310"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040014310"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-MOTOI-K-142.pdf", "filesize": [{"value": "412.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 412600.0, "url": {"label": "TE-PR-MOTOI-K-142.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9796/files/TE-PR-MOTOI-K-142.pdf"}, "version_id": "dc62d1c2-f8c8-428a-ac1d-3c2e7da1f358"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Activities", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Posture changes", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Rehabilitation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Walking speed", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Wearable monitoring system", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a new wearable monitoring system for posture changes and activities and its application to rehabilitation", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a new wearable monitoring system for posture changes and activities and its application to rehabilitation"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/23968", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9796", "relation": {}, "relation_version_is_last": true, "title": ["Development of a new wearable monitoring system for posture changes and activities and its application to rehabilitation"], "weko_shared_id": -1}
Development of a new wearable monitoring system for posture changes and activities and its application to rehabilitation
http://hdl.handle.net/2297/23968
http://hdl.handle.net/2297/23968ca5c34f1-b15c-4df2-a5b4-201860c22185
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-MOTOI-K-142.pdf (412.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Development of a new wearable monitoring system for posture changes and activities and its application to rehabilitation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Motoi, Kosuke
× Motoi, Kosuke× Kuwae, Yutaka× Taniguchi, S.× Wakugawa, M.× Yuji, Tadahiko× Higashi, Y.× Fujimoto, T.× Ogawa, M.× Tanaka, S.× Yamakoshi, Kenichi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学理工研究域機械工学系 | |||||
書誌情報 |
IFMBE Proceedings 巻 25 IFMBE, 号 9, p. 142-145, 発行日 2009-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1680-0737 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/978-3-642-03889-1-39 | |||||
出版者 | ||||||
出版者 | Springer Verlag | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to evaluate the efficacy of rehabilitation for persons with hemiplegia, a therapist usually makes judgment by directly observing posture changes, walking speed, activities not only in hospital, but also during daily living. Therefore, quantitative assessment of activities is most desirable. From this viewpoint, we have developed a device for ambulatory monitoring of posture changes, walking speed and activity scenario and evaluated its measurement accuracy by simultaneous recordings of a digital video camera. In order to investigate its applicability to a patient's activity monitoring, we have further developed a new monitoring system which can display static and dynamic motion pictures as well as detailed angle changes of the trunk, thigh and calf. This system makes a therapist to easily understand the patient's motion during training in rehabilitation center and activities during daily living. By evaluation on 6 patients with hemiplegia, the patients' motions were successfully monitored during walking in the rehabilitation center and daily living at their own home. The results clearly demonstrated that the system could detect detailed motion characteristics, indicating that the system appears useful for evaluating quantitatively the efficacy of rehabilitation. © 2009 Springer-Verlag. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |