WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "640c8b84-28cf-4ae5-ae3b-1aae1f2472ce"}, "_deposit": {"created_by": 3, "id": "9937", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9937"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009937", "sets": ["936"]}, "author_link": ["178", "78", "10974", "42", "14612"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-09-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "474", "bibliographicPageStart": "467", "bibliographicVolumeNumber": "44", "bibliographic_titles": [{"bibliographic_title": "生体医工学 : 日本エム・イー学会誌"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The daily monitoring of health conditions at home is a very important subject not only as an effective scheme for the early diagnosis and treatment of cardiovascular and other diseases, but also for the prevention and control of such diseases. From this point of view, we have been developing a fully automated \"non-conscious\" monitoring system for home healthcare. In this paper, we describe the structural details of a newly developed blood pressure (BP) measurement system built into a toilet seat and some results obtained using the system. The principle used for BP measurement was the volume-oscillometric method. A reflectance-type photop-lethysmographic sensor was installed in an appropriate position on the toilet seat, and it was automatically lifted and lowered using a newly designed helicoid-type actuator. Systolic (SBP) and mean BP (MBP) were obtained using the arterial volume pulsation signal obtained by the sensor. In order to evaluate the accuracy of the BP measurements, simultaneous measurements were carried out using two types of commercially available BP monitors (upper arm and wrist). Simultaneous measurement using an \"invasive technique\" via catheterization to the right brachial artery was also conducted. From the results obtained (bias [s.d.] for SBP; Upper arm: -1.20 [7.90] mmHg, Wrist: 0.44 [7.28] mmHg, Invasive: -0.41 [4.91] mmHg, bias [s.d.] for MBP; Upper arm: 4.40 [6.91] mmHg, Wrist: 5.07 [8.04] mmHg, Invasive: 3.68 [5.69] mmHg), reasonable accuracy of the present system was clearly demonstrated. This system, which requires no cumbersome procedures for BP measurement such as cuff setting, proper positioning of measuring site and so on, appears to be a useful means for long-term home healthcare monitoring.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学大学院自然科学研究科", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本生体医工学会"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110005716768/", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11633569", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-443X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田中, 志信"}], "nameIdentifiers": [{"nameIdentifier": "78", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40242218", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40242218"}, {"nameIdentifier": "40242218", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40242218"}, {"nameIdentifier": "40242218", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040242218"}]}, {"creatorNames": [{"creatorName": "本井, 幸介"}], "nameIdentifiers": [{"nameIdentifier": "14612", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野川, 雅道"}], "nameIdentifiers": [{"nameIdentifier": "178", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40292445", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40292445"}, {"nameIdentifier": "40292445", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40292445"}, {"nameIdentifier": "40292445", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040292445"}]}, {"creatorNames": [{"creatorName": "山越, 健弘"}], "nameIdentifiers": [{"nameIdentifier": "10974", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070444205"}]}, {"creatorNames": [{"creatorName": "山越, 憲一"}], "nameIdentifiers": [{"nameIdentifier": "42", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40014310"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040014310"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMAKOSHI-T-467.pdf", "filesize": [{"value": "770.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 770200.0, "url": {"label": "TE-PR-YAMAKOSHI-T-467.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9937/files/TE-PR-YAMAKOSHI-T-467.pdf"}, "version_id": "451da502-860e-4698-966f-a070393ca54f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "home healthcare", "subitem_subject_scheme": "Other"}, {"subitem_subject": "non-invasive blood pressure measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "volume-oscillometric method", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ホームヘルスケアのための便座内蔵型血圧計測システムの試作", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ホームヘルスケアのための便座内蔵型血圧計測システムの試作"}, {"subitem_title": "Development of a Blood Pressure Monitoring System Installed in a Toilet Seat for Use in Home Healthcare", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/14326", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9937", "relation": {}, "relation_version_is_last": true, "title": ["ホームヘルスケアのための便座内蔵型血圧計測システムの試作"], "weko_shared_id": -1}
ホームヘルスケアのための便座内蔵型血圧計測システムの試作
http://hdl.handle.net/2297/14326
http://hdl.handle.net/2297/14326d7e62fbc-8171-4dee-9e4b-50788a90ba87
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMAKOSHI-T-467.pdf (770.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | ホームヘルスケアのための便座内蔵型血圧計測システムの試作 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Development of a Blood Pressure Monitoring System Installed in a Toilet Seat for Use in Home Healthcare | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
田中, 志信
× 田中, 志信× 本井, 幸介× 野川, 雅道× 山越, 健弘× 山越, 憲一 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学大学院自然科学研究科 | |||||
書誌情報 |
生体医工学 : 日本エム・イー学会誌 巻 44, 号 3, p. 467-474, 発行日 2006-09-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-443X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11633569 | |||||
出版者 | ||||||
出版者 | 日本生体医工学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The daily monitoring of health conditions at home is a very important subject not only as an effective scheme for the early diagnosis and treatment of cardiovascular and other diseases, but also for the prevention and control of such diseases. From this point of view, we have been developing a fully automated "non-conscious" monitoring system for home healthcare. In this paper, we describe the structural details of a newly developed blood pressure (BP) measurement system built into a toilet seat and some results obtained using the system. The principle used for BP measurement was the volume-oscillometric method. A reflectance-type photop-lethysmographic sensor was installed in an appropriate position on the toilet seat, and it was automatically lifted and lowered using a newly designed helicoid-type actuator. Systolic (SBP) and mean BP (MBP) were obtained using the arterial volume pulsation signal obtained by the sensor. In order to evaluate the accuracy of the BP measurements, simultaneous measurements were carried out using two types of commercially available BP monitors (upper arm and wrist). Simultaneous measurement using an "invasive technique" via catheterization to the right brachial artery was also conducted. From the results obtained (bias [s.d.] for SBP; Upper arm: -1.20 [7.90] mmHg, Wrist: 0.44 [7.28] mmHg, Invasive: -0.41 [4.91] mmHg, bias [s.d.] for MBP; Upper arm: 4.40 [6.91] mmHg, Wrist: 5.07 [8.04] mmHg, Invasive: 3.68 [5.69] mmHg), reasonable accuracy of the present system was clearly demonstrated. This system, which requires no cumbersome procedures for BP measurement such as cuff setting, proper positioning of measuring site and so on, appears to be a useful means for long-term home healthcare monitoring. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110005716768/ |