WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "cd8a36f9-be98-4b29-a76e-e3c7a429952d"}, "_deposit": {"created_by": 3, "id": "1025", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "1025"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00001025", "sets": ["16"]}, "author_link": ["168", "4284", "4282", "4283"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-05-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "168", "bibliographicPageStart": "161", "bibliographicVolumeNumber": "27", "bibliographic_titles": [{"bibliographic_title": "Journal of physiological anthropology"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purposes of this study were to examine the relationships between various force-time parameters and muscle oxygenation kinetics during maximal sustained isometric grip (SIG) and maximal repeated rhythmic grips (RRG) with different grip intervals (interval times: 5, 4, 3, and 2 s). Subjects were 10 healthy young males, aged 20-26 years (height 173.9±7.3 cm, body mass 71.5±11.2 kg). After measuring maximal grip force, each subject performed the SIG and RRG tests with a target frequency of 12, 15, 20, and 30 grips・min^\u003c-1\u003e (interval times: 5, 4, 3, and 2 s, respectively) for 6 min. The decreasing time until 80% MVC showed significant and high correlations with final force values in RRGs with over 3 s intervals (r=0.866-0.941), but not in the SIG and RRG with a 2 s interval. The time at the lowest Oxy-Hb/Mb value showed a significant and high correlation with the time at the highest Deoxy-Hb/Mb value only in the SIG and RRG with a 2 s interval (r=0.825-0.916). Oxy-Hb/Mb decreases markedly and deoxy-Hb/Mb increases after the onset of SIG due to the obstruction of blood flow caused by the increase in intramuscular pressure. A similar physiological response to that of SIG occurs also in RRG with a 2 s interval, but RRGs with intervals over 3 s achieve more resumption of blood flow in the muscular relaxation phase. Hence, in spite of the same RRGs, it was determined that RRGs with intervals over 3 s differ significantly in a changing pattern of grip force and muscle oxygen kinetics from RRGs with a 2 s interval.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学人間社会研究域人間科学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本生理人類学会"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.2114/jpa2.27.161", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "日本生理人類学会;本文データは日本生理人類学会の許諾に基づきCiNiiから複製したものである"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12113950", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1345-3475", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Demura, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "168", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20155485"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020155485"}]}, {"creatorNames": [{"creatorName": "Nakada, Masakatsu"}], "nameIdentifiers": [{"nameIdentifier": "4282", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaji, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "4283", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagasawa, Yoshinori"}], "nameIdentifiers": [{"nameIdentifier": "4284", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ED-PR-DEMURA-S-161.pdf", "filesize": [{"value": "942.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 942200.0, "url": {"label": "ED-PR-DEMURA-S-161.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/1025/files/ED-PR-DEMURA-S-161.pdf"}, "version_id": "46446ee4-4e91-4098-9cd7-a548dcf175b2"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "force-time parameter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "muscle oxygenation kinetics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "gripping interval", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies"}]}, "item_type_id": "4", "owner": "3", "path": ["16"], "permalink_uri": "http://hdl.handle.net/2297/12257", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-02"}, "publish_date": "2017-10-02", "publish_status": "0", "recid": "1025", "relation": {}, "relation_version_is_last": true, "title": ["Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies"], "weko_shared_id": 3}
Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies
http://hdl.handle.net/2297/12257
http://hdl.handle.net/2297/122575b3b555b-a626-416f-8157-7b9e85175fd1
名前 / ファイル | ライセンス | アクション |
---|---|---|
ED-PR-DEMURA-S-161.pdf (942.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-02 | |||||
タイトル | ||||||
タイトル | Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Demura, Shinichi
× Demura, Shinichi× Nakada, Masakatsu× Yamaji, Shunsuke× Nagasawa, Yoshinori |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学人間社会研究域人間科学系 | |||||
書誌情報 |
Journal of physiological anthropology 巻 27, 号 3, p. 161-168, 発行日 2008-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1345-3475 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12113950 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.2114/jpa2.27.161 | |||||
出版者 | ||||||
出版者 | 日本生理人類学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purposes of this study were to examine the relationships between various force-time parameters and muscle oxygenation kinetics during maximal sustained isometric grip (SIG) and maximal repeated rhythmic grips (RRG) with different grip intervals (interval times: 5, 4, 3, and 2 s). Subjects were 10 healthy young males, aged 20-26 years (height 173.9±7.3 cm, body mass 71.5±11.2 kg). After measuring maximal grip force, each subject performed the SIG and RRG tests with a target frequency of 12, 15, 20, and 30 grips・min^<-1> (interval times: 5, 4, 3, and 2 s, respectively) for 6 min. The decreasing time until 80% MVC showed significant and high correlations with final force values in RRGs with over 3 s intervals (r=0.866-0.941), but not in the SIG and RRG with a 2 s interval. The time at the lowest Oxy-Hb/Mb value showed a significant and high correlation with the time at the highest Deoxy-Hb/Mb value only in the SIG and RRG with a 2 s interval (r=0.825-0.916). Oxy-Hb/Mb decreases markedly and deoxy-Hb/Mb increases after the onset of SIG due to the obstruction of blood flow caused by the increase in intramuscular pressure. A similar physiological response to that of SIG occurs also in RRG with a 2 s interval, but RRGs with intervals over 3 s achieve more resumption of blood flow in the muscular relaxation phase. Hence, in spite of the same RRGs, it was determined that RRGs with intervals over 3 s differ significantly in a changing pattern of grip force and muscle oxygen kinetics from RRGs with a 2 s interval. | |||||
権利 | ||||||
権利情報 | 日本生理人類学会;本文データは日本生理人類学会の許諾に基づきCiNiiから複製したものである | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |