WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "2d3b99d3-5dee-468a-82e9-2339b787cc44"}, "_deposit": {"created_by": 3, "id": "1029", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "1029"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00001029", "sets": ["16"]}, "author_link": ["168", "4287"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-08-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "61", "bibliographicPageStart": "51", "bibliographicVolumeNumber": "213", "bibliographic_titles": [{"bibliographic_title": "Tohoku Journal of Experimental Medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Measurement of subcutaneous fat thickness with a skinfold caliper is a simple and inexpensive technique for assessment of body composition, but is influenced by the skin site or the obesity level. The resulting measurement errors may influence the prediction accuracy of body density. We therefore aimed to clarify the characteristics of measurement errors with a skinfold caliper and to determine useful measurement sites for the prediction of body density in Japanese adults of wide-ranging age and obesity levels. The present study included 126 Japanese male and 77 female subjects ranging from 21 to 81 years old. They were divided into a \"non-obese group\" and an \"obese group\", based on the Japanese criteria of obesity (BMI ≥ 25 kg/m2). Subcutaneous fat thickness was measured at 14 sites with a skinfold caliper and ultrasound. Percent body fat was measured by dual-energy x-ray absorptiometry, and body density was calculated using Brozek\u0027s formula. Sex and obesity level differences in the measurement error of skinfolds (ultrasound minus skinfold caliper measurements) were examined by 2 × 2 ANOVA (sex and obesity groups) for each site. The relationship between body density and the systematic error was examined. We developed an accurate prediction equation for body density with smaller measurement and systematic errors. Although measurement errors in skinfold thickness tended to increase with increasing obesity levels, the influence was smaller for the abdominal and suprailiac skinfolds compared with other sites. Measurement of suprailiac or abdominal skinfold thickness is useful to accurately estimate body density in Japanese adults. © 2007 Tohoku University Medical Press.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学人間社会研究域人間科学系", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東北大学 : 東北ジャーナル刊行会"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1620/tjem.213.51", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://journal.med.tohoku.ac.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1620/tjem.213.51", "subitem_relation_type_select": "DOI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jstage.jst.go.jp/article/tjem/213/1/213_51/_article", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2007 Tohoku University Medical Press"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00863920", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0040-8727", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Demura, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "168", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20155485"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020155485"}]}, {"creatorNames": [{"creatorName": "Sato, Susumu"}], "nameIdentifiers": [{"nameIdentifier": "4287", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ED-PR-DEMURA-S-51.pdf", "filesize": [{"value": "723.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 723900.0, "url": {"label": "ED-PR-DEMURA-S-51.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/1029/files/ED-PR-DEMURA-S-51.pdf"}, "version_id": "df793493-7c82-48c4-8193-3abd3737e325"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Anthropometry", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Measurement error", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Skinfold caliper", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Systematic error", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ultrasound", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults"}]}, "item_type_id": "4", "owner": "3", "path": ["16"], "permalink_uri": "http://hdl.handle.net/2297/16868", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-02"}, "publish_date": "2017-10-02", "publish_status": "0", "recid": "1029", "relation": {}, "relation_version_is_last": true, "title": ["Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults"], "weko_shared_id": -1}
Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults
http://hdl.handle.net/2297/16868
http://hdl.handle.net/2297/168688f8f1ed7-1d8a-4160-ba6a-1959955f2d49
名前 / ファイル | ライセンス | アクション |
---|---|---|
ED-PR-DEMURA-S-51.pdf (723.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-02 | |||||
タイトル | ||||||
タイトル | Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Demura, Shinichi
× Demura, Shinichi× Sato, Susumu |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学人間社会研究域人間科学系 | |||||
書誌情報 |
Tohoku Journal of Experimental Medicine 巻 213, 号 1, p. 51-61, 発行日 2007-08-31 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0040-8727 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00863920 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1620/tjem.213.51 | |||||
出版者 | ||||||
出版者 | 東北大学 : 東北ジャーナル刊行会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Measurement of subcutaneous fat thickness with a skinfold caliper is a simple and inexpensive technique for assessment of body composition, but is influenced by the skin site or the obesity level. The resulting measurement errors may influence the prediction accuracy of body density. We therefore aimed to clarify the characteristics of measurement errors with a skinfold caliper and to determine useful measurement sites for the prediction of body density in Japanese adults of wide-ranging age and obesity levels. The present study included 126 Japanese male and 77 female subjects ranging from 21 to 81 years old. They were divided into a "non-obese group" and an "obese group", based on the Japanese criteria of obesity (BMI ≥ 25 kg/m2). Subcutaneous fat thickness was measured at 14 sites with a skinfold caliper and ultrasound. Percent body fat was measured by dual-energy x-ray absorptiometry, and body density was calculated using Brozek's formula. Sex and obesity level differences in the measurement error of skinfolds (ultrasound minus skinfold caliper measurements) were examined by 2 × 2 ANOVA (sex and obesity groups) for each site. The relationship between body density and the systematic error was examined. We developed an accurate prediction equation for body density with smaller measurement and systematic errors. Although measurement errors in skinfold thickness tended to increase with increasing obesity levels, the influence was smaller for the abdominal and suprailiac skinfolds compared with other sites. Measurement of suprailiac or abdominal skinfold thickness is useful to accurately estimate body density in Japanese adults. © 2007 Tohoku University Medical Press. | |||||
権利 | ||||||
権利情報 | Copyright (c) 2007 Tohoku University Medical Press | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://journal.med.tohoku.ac.jp/ | |||||
関連URI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1620/tjem.213.51 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jstage.jst.go.jp/article/tjem/213/1/213_51/_article |