WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "c7d23266-d2f4-4668-88d5-5ac7a0361ff6"}, "_deposit": {"created_by": 3, "id": "10748", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "10748"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00010748", "sets": ["937"]}, "author_link": ["2577", "114", "1734", "262"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-09-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "July/August 2014", "bibliographicPageEnd": "220", "bibliographicPageStart": "213", "bibliographicVolumeNumber": "62", "bibliographic_titles": [{"bibliographic_title": "Cryogenics"}]}]}, "item_4_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "阿部, 聡 "}], "nameIdentifiers": [{"nameIdentifier": "2577", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60251914", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60251914"}]}, {"creatorNames": [{"creatorName": "松本, 宏一"}], "nameIdentifiers": [{"nameIdentifier": "1734", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10219496", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10219496"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Nuclear demagnetization is one of the most successful methods of cooling an appreciable amount of matter to the lowest temperatures. The principle of nuclear demagnetization is the same as that of the adiabatic demagnetization of a paramagnetic salt; however, there is a significant difference in practice. This article focuses on nuclear demagnetization refrigeration used in experiments at millikelvin and much lower temperatures. After a brief overview of the basic principle and methods, typical requirements of the refrigerants are described from the view point of experiments. The heat switch and thermometry used in nuclear demagnetization experiments are also discussed. © 2014 Elsevier Ltd. All rights reserved.", "subitem_description_type": "Abstract"}]}, "item_4_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00010735", "subitem_identifier_reg_type": "JaLC"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.cryogenics.2014.04.004", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.elsevier.com/locate/issn/00112275", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00620634", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0011-2275", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Abe, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "262", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60251914", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60251914"}, {"nameIdentifier": "60251914", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060251914"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "114", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10219496", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10219496"}, {"nameIdentifier": "10219496", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010219496"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SC-PR-ABE-S-213.pdf", "filesize": [{"value": "261.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 261800.0, "url": {"label": "SC-PR-ABE-S-213.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/10748/files/SC-PR-ABE-S-213.pdf"}, "version_id": "df47a180-bd5d-4f90-be72-924516d07c65"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Nuclear demagnetization for ultra-low temperatures", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Nuclear demagnetization for ultra-low temperatures"}]}, "item_type_id": "4", "owner": "3", "path": ["937"], "permalink_uri": "https://doi.org/10.24517/00010735", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "10748", "relation": {}, "relation_version_is_last": true, "title": ["Nuclear demagnetization for ultra-low temperatures"], "weko_shared_id": 3}
Nuclear demagnetization for ultra-low temperatures
https://doi.org/10.24517/00010735
https://doi.org/10.24517/00010735c551a1d0-a149-481a-819c-c10d452b33d2
名前 / ファイル | ライセンス | アクション |
---|---|---|
SC-PR-ABE-S-213.pdf (261.8 kB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Nuclear demagnetization for ultra-low temperatures | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.24517/00010735 | |||||
ID登録タイプ | JaLC | |||||
著者 |
Abe, Satoshi
× Abe, Satoshi× Matsumoto, Koichi |
|||||
著者別表示 |
阿部, 聡
× 阿部, 聡× 松本, 宏一 |
|||||
書誌情報 |
Cryogenics 巻 62, 号 July/August 2014, p. 213-220, 発行日 2014-09-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0011-2275 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00620634 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.cryogenics.2014.04.004 | |||||
出版者 | ||||||
出版者 | Elsevier | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Nuclear demagnetization is one of the most successful methods of cooling an appreciable amount of matter to the lowest temperatures. The principle of nuclear demagnetization is the same as that of the adiabatic demagnetization of a paramagnetic salt; however, there is a significant difference in practice. This article focuses on nuclear demagnetization refrigeration used in experiments at millikelvin and much lower temperatures. After a brief overview of the basic principle and methods, typical requirements of the refrigerants are described from the view point of experiments. The heat switch and thermometry used in nuclear demagnetization experiments are also discussed. © 2014 Elsevier Ltd. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/00112275 |