{"_buckets": {"deposit": "79b0802f-f18a-4b90-96cb-c7dccabb16d8"}, "_deposit": {"created_by": 3, "id": "13156", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13156"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013156", "sets": ["1134"]}, "author_link": ["20982", "20985", "20980", "20981", "20984", "389", "20983", "20979"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-09-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "801", "bibliographicPageStart": "799", "bibliographicVolumeNumber": "67", "bibliographic_titles": [{"bibliographic_title": "Circulation Journal"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Hemolytic anemia following mitral valve repair and annular ring placement is uncommon compared with mitral valve replacement. A 60-year-old man, who had undergone mitral valve repair with a Duran ring, developed hemolytic anemia and needed a blood transfusion. Transesophageal echocardiography revealed a paravalvular mitral regurgitation jet colliding with the Duran ring. Most cases of severe hemolysis after mitral valve repair have undergone reoperation, but in the present case study, the hemolysis after mitral valve repair reduced without the need for reoperation, although the paravalvular mitral regurgitation jet continued to collide with the Duran ring.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学大学院医学系研究科 ", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本循環器学会"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1253/circj.67.799", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "日本循環器学会の許諾を得て登録"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11591968", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1346-9843", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Inoue, Masaru"}], "nameIdentifiers": [{"nameIdentifier": "20979", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kaku, Bunji"}], "nameIdentifiers": [{"nameIdentifier": "20980", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanaya, Hounin"}], "nameIdentifiers": [{"nameIdentifier": "20981", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohka, Takio"}], "nameIdentifiers": [{"nameIdentifier": "20982", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueda, Mikio"}], "nameIdentifiers": [{"nameIdentifier": "20983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Seki, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "20984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu, Masumi"}], "nameIdentifiers": [{"nameIdentifier": "20985", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mabuchi, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "389", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00019960", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00019960"}, {"nameIdentifier": "00019960", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000000019960"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MABUCHI-H-P799.pdf", "filesize": [{"value": "140.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 140200.0, "url": {"label": "ME-PR-MABUCHI-H-P799.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13156/files/ME-PR-MABUCHI-H-P799.pdf"}, "version_id": "870e8443-b7aa-498f-99e4-5f7320b29671"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Hemolysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mitral valve repair", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Reoperation", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Reduction of hemolysis without reoperation following mitral valve repair", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Reduction of hemolysis without reoperation following mitral valve repair"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/7191", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13156", "relation": {}, "relation_version_is_last": true, "title": ["Reduction of hemolysis without reoperation following mitral valve repair"], "weko_shared_id": 3}
Reduction of hemolysis without reoperation following mitral valve repair
http://hdl.handle.net/2297/7191
http://hdl.handle.net/2297/7191a717b424-22fc-4345-9e41-42c656341440
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MABUCHI-H-P799.pdf (140.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Reduction of hemolysis without reoperation following mitral valve repair | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Inoue, Masaru
× Inoue, Masaru× Kaku, Bunji× Kanaya, Hounin× Ohka, Takio× Ueda, Mikio× Seki, Masahiro× Shimizu, Masumi× Mabuchi, Hiroshi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学大学院医学系研究科 | |||||
書誌情報 |
Circulation Journal 巻 67, 号 9, p. 799-801, 発行日 2003-09-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1346-9843 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11591968 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1253/circj.67.799 | |||||
出版者 | ||||||
出版者 | 日本循環器学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Hemolytic anemia following mitral valve repair and annular ring placement is uncommon compared with mitral valve replacement. A 60-year-old man, who had undergone mitral valve repair with a Duran ring, developed hemolytic anemia and needed a blood transfusion. Transesophageal echocardiography revealed a paravalvular mitral regurgitation jet colliding with the Duran ring. Most cases of severe hemolysis after mitral valve repair have undergone reoperation, but in the present case study, the hemolysis after mitral valve repair reduced without the need for reoperation, although the paravalvular mitral regurgitation jet continued to collide with the Duran ring. | |||||