WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "5b7e2293-865c-4210-862d-06014e0164aa"}, "_deposit": {"created_by": 3, "id": "13570", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13570"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013570", "sets": ["1134"]}, "author_link": ["22513", "599", "22512", "22510", "22511", "264", "320", "22509"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageEnd": "579", "bibliographicPageStart": "571", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "Annals of Nuclear Medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objective: We have developed freeware package for automatically quantifying myocardial perfusion and 123I-labeled radiopharmaceutical single-photon emission computed tomography (SPECT), which is called \"cardioBull\". We aim to evaluate diagnostic performance of the detection of coronary artery disease (CAD) on the developed software in comparison with commercially available software package [Quantitative Perfusion SPECT (QPS)]. Methods: Stress-rest 99mTc-sestamibi myocardial perfusion SPECT was performed in 36 patients with CAD and 35 control patients. A ≥75% stenosis in the coronary artery was identified by coronary angiography in the CAD group. Segmental perfusion defect score was automatically calculated by both cardioBull and QPS software. Summed stress score (SSS) was obtained to detect CAD by the receiver operator characteristic (ROC) analysis. Areas under the ROC curves (AUC) were calculated in patient-based and coronary-based analyses. Results: Mean SSSs showed no significant difference between cardioBull and QPS (6.0 ± 7.1 vs. 5.6 ± 7.0). The AUC for cardioBull was equivalent to that for QPS (0.91 ± 0.04 vs. 0.87 ± 0.04, p = n.s.). Sensitivity, specificity, and accuracy for cardioBull were 89, 74, and 82%, respectively. For the regional detection of CAD, the AUC showed largest value in left anterior descending coronary artery (LAD) territory (0.86 ± 0.06 for cardioBull, 0.87 ± 0.06 for QPS, p = n.s.). Sensitivity, specificity and accuracy of cardioBull were 70, 88, and 83% for the LAD; 91, 62, and 66% for the left circumflex coronary artery (LCx); and 78, 69, and 70% for the right coronary artery (RCA), respectively. Conclusions: The AUC, sensitivity, specificity and accuracy for the detection of CAD showed high diagnostic performance on the developed software. In addition, the developed software provided comparable diagnostic performance to the commercially available software package. © 2011 The Japanese Society of Nuclear Medicine.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Verlag (Germany) / 日本核医学会 = the Japanese Society of Nuclear Medicine"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12149-011-0504-0", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10708017", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-7187", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Okuda, Koichi"}], "nameIdentifiers": [{"nameIdentifier": "22509", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "320", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000000167545"}]}, {"creatorNames": [{"creatorName": "Hosoya, Tetsuo"}], "nameIdentifiers": [{"nameIdentifier": "22510", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "22511", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuo, Shinro"}], "nameIdentifiers": [{"nameIdentifier": "599", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30359773"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030359773"}]}, {"creatorNames": [{"creatorName": "Kawano, Masaya"}], "nameIdentifiers": [{"nameIdentifier": "22512", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taki, Junichi"}], "nameIdentifiers": [{"nameIdentifier": "264", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00167545"}, {"nameIdentifier": "10251927", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10251927"}, {"nameIdentifier": "10251927", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010251927"}]}, {"creatorNames": [{"creatorName": "Kinuya, Seigo"}], "nameIdentifiers": [{"nameIdentifier": "22513", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20281024"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-OKUDA-K-571.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "ME-PR-OKUDA-K-571.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13570/files/ME-PR-OKUDA-K-571.pdf"}, "version_id": "9d072278-30ed-4da1-9c24-0209492fb01e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Automatic quantification", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Coronary artery disease", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Image processing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Myocardial perfusion SPECT", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Quantification of myocardial perfusion SPECT using freeware package (cardioBull)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Quantification of myocardial perfusion SPECT using freeware package (cardioBull)"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/29527", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13570", "relation": {}, "relation_version_is_last": true, "title": ["Quantification of myocardial perfusion SPECT using freeware package (cardioBull)"], "weko_shared_id": -1}
Quantification of myocardial perfusion SPECT using freeware package (cardioBull)
http://hdl.handle.net/2297/29527
http://hdl.handle.net/2297/295277abe1ee1-c3c1-46c0-adda-a4efaa68b07c
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-OKUDA-K-571.pdf (1.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Quantification of myocardial perfusion SPECT using freeware package (cardioBull) | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Okuda, Koichi
× Okuda, Koichi× Nakajima, Kenichi× Hosoya, Tetsuo× Ishikawa, Takehiro× Matsuo, Shinro× Kawano, Masaya× Taki, Junichi× Kinuya, Seigo |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 25, 号 8, p. 571-579, 発行日 2011-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10708017 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-011-0504-0 | |||||
出版者 | ||||||
出版者 | Springer Verlag (Germany) / 日本核医学会 = the Japanese Society of Nuclear Medicine | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: We have developed freeware package for automatically quantifying myocardial perfusion and 123I-labeled radiopharmaceutical single-photon emission computed tomography (SPECT), which is called "cardioBull". We aim to evaluate diagnostic performance of the detection of coronary artery disease (CAD) on the developed software in comparison with commercially available software package [Quantitative Perfusion SPECT (QPS)]. Methods: Stress-rest 99mTc-sestamibi myocardial perfusion SPECT was performed in 36 patients with CAD and 35 control patients. A ≥75% stenosis in the coronary artery was identified by coronary angiography in the CAD group. Segmental perfusion defect score was automatically calculated by both cardioBull and QPS software. Summed stress score (SSS) was obtained to detect CAD by the receiver operator characteristic (ROC) analysis. Areas under the ROC curves (AUC) were calculated in patient-based and coronary-based analyses. Results: Mean SSSs showed no significant difference between cardioBull and QPS (6.0 ± 7.1 vs. 5.6 ± 7.0). The AUC for cardioBull was equivalent to that for QPS (0.91 ± 0.04 vs. 0.87 ± 0.04, p = n.s.). Sensitivity, specificity, and accuracy for cardioBull were 89, 74, and 82%, respectively. For the regional detection of CAD, the AUC showed largest value in left anterior descending coronary artery (LAD) territory (0.86 ± 0.06 for cardioBull, 0.87 ± 0.06 for QPS, p = n.s.). Sensitivity, specificity and accuracy of cardioBull were 70, 88, and 83% for the LAD; 91, 62, and 66% for the left circumflex coronary artery (LCx); and 78, 69, and 70% for the right coronary artery (RCA), respectively. Conclusions: The AUC, sensitivity, specificity and accuracy for the detection of CAD showed high diagnostic performance on the developed software. In addition, the developed software provided comparable diagnostic performance to the commercially available software package. © 2011 The Japanese Society of Nuclear Medicine. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |