WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "a7c0e96c-b698-4944-812f-1f84ec24f8f6"}, "_deposit": {"created_by": 3, "id": "13757", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13757"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013757", "sets": ["1134"]}, "author_link": ["95058", "693", "95057", "95056", "460", "23065", "13121", "95059"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "175", "bibliographicPageStart": "170", "bibliographicVolumeNumber": "20", "bibliographic_titles": [{"bibliographic_title": "医用画像情報学会雑誌 = Medical Imaging and Information Sciences"}]}]}, "item_4_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hayashi, Norio"}], "nameIdentifiers": [{"nameIdentifier": "95056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sanada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "95057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "95058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuura, Yukihiro"}], "nameIdentifiers": [{"nameIdentifier": "95059", "nameIdentifierScheme": "WEKO"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "MR imaging is a very important method for the diagnosis of intracranial lesions. A measurement of the volume of the temporal lobe is a very useful method in diagnosing temporal lobe abnormalities. Therefore we develop the algorithm of the automated volumetry of the temporal lobe. However, it is often difficult to segment the temporal lobe. The Sylvian fissure is an important index for the segmentation of the temporal lobe. The purpose of this study is to develop the algorithm of the automated identification of the Sylvian fissure. We studied 10 normal volunteers and 2 patients who were suspected of Alzheimer disease. We performed the following four steps: (1) Segmentation of the brain on coronal images. (2) Edge enhancement of the y-direction on sagittal images. (3) Hough transform on edge-enhanced images. (4) Correction of R-L direction and S-I direction. In results, this method proved to be able to identify the Sylvian fissure on coronal and sagittal MR images in normal volunteers and patients. It is concluded that the Sylvian fissure identified by this method is a very useful index of the segmentation of the temporal lobe.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.11318/mii1984.20.170", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/mii/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.mii-sci.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10156808", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-1543", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "林, 則夫"}], "nameIdentifiers": [{"nameIdentifier": "460", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90387853", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=90387853"}, {"nameIdentifier": "90387853", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090387853"}]}, {"creatorNames": [{"creatorName": "真田, 茂"}], "nameIdentifiers": [{"nameIdentifier": "13121", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50020029"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050020029"}]}, {"creatorNames": [{"creatorName": "鈴木, 正行"}], "nameIdentifiers": [{"nameIdentifier": "693", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70111325", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070111325"}]}, {"creatorNames": [{"creatorName": "松浦, 幸広"}], "nameIdentifiers": [{"nameIdentifier": "23065", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-SANADA-S-170.pdf", "filesize": [{"value": "5.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 5800000.0, "url": {"label": "ME-PR-SANADA-S-170.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13757/files/ME-PR-SANADA-S-170.pdf"}, "version_id": "8b3a1d3f-fe14-499f-9334-e0f3548f8e0b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Sylvian fissure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Hough Transform", "subitem_subject_scheme": "Other"}, {"subitem_subject": "MRI", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "頭部MR画像におけるシルビウス裂検出法の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "頭部MR画像におけるシルビウス裂検出法の開発"}, {"subitem_title": "Development of Identification Method of Sylvian Fissure on Brain MR Images", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/36653", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13757", "relation": {}, "relation_version_is_last": true, "title": ["頭部MR画像におけるシルビウス裂検出法の開発"], "weko_shared_id": 3}
頭部MR画像におけるシルビウス裂検出法の開発
http://hdl.handle.net/2297/36653
http://hdl.handle.net/2297/36653992986e4-c314-46ce-afb4-68a6b541349e
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-SANADA-S-170.pdf (5.8 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 頭部MR画像におけるシルビウス裂検出法の開発 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Development of Identification Method of Sylvian Fissure on Brain MR Images | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
林, 則夫
× 林, 則夫× 真田, 茂× 鈴木, 正行× 松浦, 幸広 |
|||||
著者別表示 |
Hayashi, Norio
× Hayashi, Norio× Sanada, Shigeru× Suzuki, Masayuki× Matsuura, Yukihiro |
|||||
書誌情報 |
医用画像情報学会雑誌 = Medical Imaging and Information Sciences 巻 20, 号 3, p. 170-175, 発行日 2003-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-1543 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10156808 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.11318/mii1984.20.170 | |||||
出版者 | ||||||
出版者 | 医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | MR imaging is a very important method for the diagnosis of intracranial lesions. A measurement of the volume of the temporal lobe is a very useful method in diagnosing temporal lobe abnormalities. Therefore we develop the algorithm of the automated volumetry of the temporal lobe. However, it is often difficult to segment the temporal lobe. The Sylvian fissure is an important index for the segmentation of the temporal lobe. The purpose of this study is to develop the algorithm of the automated identification of the Sylvian fissure. We studied 10 normal volunteers and 2 patients who were suspected of Alzheimer disease. We performed the following four steps: (1) Segmentation of the brain on coronal images. (2) Edge enhancement of the y-direction on sagittal images. (3) Hough transform on edge-enhanced images. (4) Correction of R-L direction and S-I direction. In results, this method proved to be able to identify the Sylvian fissure on coronal and sagittal MR images in normal volunteers and patients. It is concluded that the Sylvian fissure identified by this method is a very useful index of the segmentation of the temporal lobe. | |||||
権利 | ||||||
権利情報 | Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/mii/-char/ja/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.mii-sci.jp/ |