{"_buckets": {"deposit": "6a5b4b3f-2a89-4c86-a1a2-887d620d52ab"}, "_deposit": {"created_by": 3, "id": "14054", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14054"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014054", "sets": ["1134"]}, "author_link": ["23920", "20391", "23921", "20665", "23922", "10713"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "4701", "bibliographicPageStart": "4693", "bibliographicVolumeNumber": "27", "bibliographic_titles": [{"bibliographic_title": "Surgical Endoscopy and Other Interventional Techniques"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive operation using devices such as flexible endoscopes and linear or circular staplers. Nevertheless, hand-sewn anastomosis in NOTES remains challenging. This study aimed to investigate the feasibility of transrectal robotic NOTES requiring intracorporeal small intestinal anastomosis and closure of the rectal anterior wall incision in a relevant human model. Methods: The authors developed a flexible rectal proctoscope with a diameter of 43 mm for transrectal robotic NOTES. Small intestinal anastomosis was performed in a porcine intestinal transrectal NOTES model using two robotic arms and a camera inserted through the proctoscope and a rectal anterior wall incision. The quality of transrectal small intestinal anastomosis using the da Vinci surgical system (transrectal robotic NOTES group) was compared with that of transabdominal anastomosis using the da Vinci surgical system (transabdominal robot-assisted surgery group) and transrectal anastomosis using traditional transanal endoscopic microsurgery (TEM) instruments (TEM NOTES group). The quality of transrectal rectal anterior wall suturing in the transrectal robotic NOTES group was compared with that of the TEM NOTES group and the open surgical instruments group (open group). Results: Robotic intracorporeal suturing was performed successfully in the porcine intestine model. During small intestinal anastomosis, burst pressure in the transrectal robotic NOTES group (67.7 ± 29.3 mmHg) was similar to that in the transabdominal robot-assisted surgery group (73.3 ± 18.2 mmHg) but significantly higher than in the TEM NOTES group (20.3 ± 24.0 mmHg; p \u003c 0.01). During rectal anterior wall suturing, the burst pressure did not differ significantly between the transrectal robotic NOTES group (149.9 ± 81.1 mmHg) and the open group (195.0 ± 60.5 mmHg). Conclusions: The preliminary safety and efficacy of transrectal robotic NOTES was established. Further studies are required to determine the practical feasibility of this procedure. © 2013 Springer Science+Business Media New York.", "subitem_description_type": "Abstract"}]}, "item_4_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "in Press", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Science+Business"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s00464-013-3117-y", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10750363", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0930-2794", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Demura, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "23920", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishikawa, Norihiko"}], "nameIdentifiers": [{"nameIdentifier": "20391", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50343182", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50343182"}, {"nameIdentifier": "50343182", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050343182"}]}, {"creatorNames": [{"creatorName": "Hirano, Yasumitsu"}], "nameIdentifiers": [{"nameIdentifier": "20665", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50422647", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50422647"}, {"nameIdentifier": "50422647", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050422647"}]}, {"creatorNames": [{"creatorName": "Inaki, Noriyuki"}], "nameIdentifiers": [{"nameIdentifier": "23921", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40436837", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040436837"}]}, {"creatorNames": [{"creatorName": "Matsunoki, Aika"}], "nameIdentifiers": [{"nameIdentifier": "23922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Go"}], "nameIdentifiers": [{"nameIdentifier": "10713", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60242492", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060242492"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-DEMURA-Y-4693.pdf", "filesize": [{"value": "404.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 404700.0, "url": {"label": "ME-PR-DEMURA-Y-4693.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14054/files/ME-PR-DEMURA-Y-4693.pdf"}, "version_id": "400866ca-d67e-403f-8f6e-49ea9eb2556e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Anastomosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "NOTES", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Robotic surgery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Transrectal", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Transrectal robotic natural orifice translumenal endoscopic surgery (NOTES) applied to intestinal anastomosis in a porcine intestine model", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Transrectal robotic natural orifice translumenal endoscopic surgery (NOTES) applied to intestinal anastomosis in a porcine intestine model"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/35624", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14054", "relation": {}, "relation_version_is_last": true, "title": ["Transrectal robotic natural orifice translumenal endoscopic surgery (NOTES) applied to intestinal anastomosis in a porcine intestine model"], "weko_shared_id": -1}
Transrectal robotic natural orifice translumenal endoscopic surgery (NOTES) applied to intestinal anastomosis in a porcine intestine model
http://hdl.handle.net/2297/35624
http://hdl.handle.net/2297/356241a713c33-40b0-49df-a734-047ef78afa32
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-DEMURA-Y-4693.pdf (404.7 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Transrectal robotic natural orifice translumenal endoscopic surgery (NOTES) applied to intestinal anastomosis in a porcine intestine model | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Demura, Yoshitaka
× Demura, Yoshitaka× Ishikawa, Norihiko× Hirano, Yasumitsu× Inaki, Noriyuki× Matsunoki, Aika× Watanabe, Go |
|||||
書誌情報 |
Surgical Endoscopy and Other Interventional Techniques 巻 27, 号 12, p. 4693-4701, 発行日 2013-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0930-2794 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10750363 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s00464-013-3117-y | |||||
出版者 | ||||||
出版者 | Springer Science+Business | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive operation using devices such as flexible endoscopes and linear or circular staplers. Nevertheless, hand-sewn anastomosis in NOTES remains challenging. This study aimed to investigate the feasibility of transrectal robotic NOTES requiring intracorporeal small intestinal anastomosis and closure of the rectal anterior wall incision in a relevant human model. Methods: The authors developed a flexible rectal proctoscope with a diameter of 43 mm for transrectal robotic NOTES. Small intestinal anastomosis was performed in a porcine intestinal transrectal NOTES model using two robotic arms and a camera inserted through the proctoscope and a rectal anterior wall incision. The quality of transrectal small intestinal anastomosis using the da Vinci surgical system (transrectal robotic NOTES group) was compared with that of transabdominal anastomosis using the da Vinci surgical system (transabdominal robot-assisted surgery group) and transrectal anastomosis using traditional transanal endoscopic microsurgery (TEM) instruments (TEM NOTES group). The quality of transrectal rectal anterior wall suturing in the transrectal robotic NOTES group was compared with that of the TEM NOTES group and the open surgical instruments group (open group). Results: Robotic intracorporeal suturing was performed successfully in the porcine intestine model. During small intestinal anastomosis, burst pressure in the transrectal robotic NOTES group (67.7 ± 29.3 mmHg) was similar to that in the transabdominal robot-assisted surgery group (73.3 ± 18.2 mmHg) but significantly higher than in the TEM NOTES group (20.3 ± 24.0 mmHg; p < 0.01). During rectal anterior wall suturing, the burst pressure did not differ significantly between the transrectal robotic NOTES group (149.9 ± 81.1 mmHg) and the open group (195.0 ± 60.5 mmHg). Conclusions: The preliminary safety and efficacy of transrectal robotic NOTES was established. Further studies are required to determine the practical feasibility of this procedure. © 2013 Springer Science+Business Media New York. | |||||