WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "97050388-9fd6-479c-ad41-83bb19454e30"}, "_deposit": {"created_by": 3, "id": "14231", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14231"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014231", "sets": ["1134"]}, "author_link": ["384", "22694", "24473", "24472"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-08-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageStart": "135", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "BMC Ophthalmology"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet\u0027s stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet\u0027s membrane endothelial keratoplasty (DMEK) donor tissue. Methods: Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor. Results: For each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet\u0027s membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber. Conclusion: Rapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater. © 2016 Kobayashi et al.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "BioMed Central"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1186/s12886-016-0308-z", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1471-2415", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kobayashi, Akira"}], "nameIdentifiers": [{"nameIdentifier": "384", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20303274", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20303274"}, {"nameIdentifier": "20303274", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=20303274"}, {"nameIdentifier": "20303274", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020303274"}]}, {"creatorNames": [{"creatorName": "Yokogawa, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "24472", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70608695", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70608695"}, {"nameIdentifier": "70608695", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=70608695"}, {"nameIdentifier": "70608695", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070608695"}]}, {"creatorNames": [{"creatorName": "Mori, Natsuko"}], "nameIdentifiers": [{"nameIdentifier": "24473", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80768747", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80768747"}]}, {"creatorNames": [{"creatorName": "Sugiyama, Kazuhisa"}], "nameIdentifiers": [{"nameIdentifier": "22694", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80179168", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80179168"}, {"nameIdentifier": "80179168", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080179168"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-KOBAYASHI-A-135.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1900000.0, "url": {"label": "ME-PR-KOBAYASHI-A-135.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14231/files/ME-PR-KOBAYASHI-A-135.pdf"}, "version_id": "914c40ab-0fb6-45ab-be67-9e598116f63d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Descemet\u0027s membrane endothelial keratoplasty", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Descemet\u0027s stripping automated endothelial keratoplasty", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Intraoperative OCT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "RESCAN 700", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/47010", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14231", "relation": {}, "relation_version_is_last": true, "title": ["Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700"], "weko_shared_id": -1}
Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700
http://hdl.handle.net/2297/47010
http://hdl.handle.net/2297/47010812bb684-8e0a-4ec5-b8ce-a8d5a06322df
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-KOBAYASHI-A-135.pdf (1.9 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kobayashi, Akira
× Kobayashi, Akira× Yokogawa, Hideaki× Mori, Natsuko× Sugiyama, Kazuhisa |
|||||
書誌情報 |
BMC Ophthalmology 巻 16, 号 1, p. 135, 発行日 2016-08-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1471-2415 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1186/s12886-016-0308-z | |||||
出版者 | ||||||
出版者 | BioMed Central | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet's stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet's membrane endothelial keratoplasty (DMEK) donor tissue. Methods: Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor. Results: For each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet's membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber. Conclusion: Rapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater. © 2016 Kobayashi et al. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |