WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "057ee042-9377-4947-8125-edf6a251a2cb"}, "_deposit": {"created_by": 3, "id": "15186", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "15186"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00015186", "sets": ["1135"]}, "author_link": ["27419", "35", "27420", "27421", "27264"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1990-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "337", "bibliographicPageStart": "332", "bibliographicVolumeNumber": "36", "bibliographic_titles": [{"bibliographic_title": "衛生化学"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A simultaneous determination method for five organic acids in vinegar has been established by photometric ion chromatography. Both trace components (lactic, gluconic, succinic and pyroglutamic acids) and the major component (acetic acid) in vinegar were separated on a TSK gel IC-Anion-PW column with 0.45 mM o-aminobenzenesulfonic acid aqueous solution as an eluent. Their elutions were detected as positive peaks before the system peak, and a negative peak after that by a UV monitor. The sensitivities of trace components were enhanced by adjusting their elutions close to the system peak. The lowest detection limits were 10μM lactic acid, 5μM gluconic and succinic acids and 3μM pyroglutamic acid, respectively. The only pretreatment necessary was dilution of vinegar 100-fold with the eluent. The results obtained by the proposed method were in good agreement with those by the enzymatic one.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本薬学会 = The Pharmaceutical Society of Japan"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1248/jhs1956.36.332", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.pharm.or.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jhs1956/-char/ja/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © The Pharmaceutical Society of Japan"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00021540", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0013-273X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamamoto, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "27419", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsunaga, Akinobu"}], "nameIdentifiers": [{"nameIdentifier": "27420", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizukami, Eiichi"}], "nameIdentifiers": [{"nameIdentifier": "27421", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayakawa, Kazuichi"}], "nameIdentifiers": [{"nameIdentifier": "35", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40115267"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40115267"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040115267"}]}, {"creatorNames": [{"creatorName": "Miyazaki, Motoichi"}], "nameIdentifiers": [{"nameIdentifier": "27264", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50009164", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50009164"}, {"nameIdentifier": "50009164", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050009164"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "PH-PR-HAYAKAWA-K-332.pdf", "filesize": [{"value": "627.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 627500.0, "url": {"label": "PH-PR-HAYAKAWA-K-332.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/15186/files/PH-PR-HAYAKAWA-K-332.pdf"}, "version_id": "f97226c1-c10a-48a2-a1e4-bf5971f9a03c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Photometric ion chromatography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "simultaneous determination", "subitem_subject_scheme": "Other"}, {"subitem_subject": "organic acid", "subitem_subject_scheme": "Other"}, {"subitem_subject": "vinegar", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Simultaneous Determination of Organic Acids in Commercial Vinegar by Photometric Ion Chromatography", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simultaneous Determination of Organic Acids in Commercial Vinegar by Photometric Ion Chromatography"}]}, "item_type_id": "4", "owner": "3", "path": ["1135"], "permalink_uri": "http://hdl.handle.net/2297/44929", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-04"}, "publish_date": "2017-10-04", "publish_status": "0", "recid": "15186", "relation": {}, "relation_version_is_last": true, "title": ["Simultaneous Determination of Organic Acids in Commercial Vinegar by Photometric Ion Chromatography"], "weko_shared_id": -1}
Simultaneous Determination of Organic Acids in Commercial Vinegar by Photometric Ion Chromatography
http://hdl.handle.net/2297/44929
http://hdl.handle.net/2297/44929fdb37ba8-f385-4db4-8cab-f17dc1cddb20
名前 / ファイル | ライセンス | アクション |
---|---|---|
PH-PR-HAYAKAWA-K-332.pdf (627.5 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | Simultaneous Determination of Organic Acids in Commercial Vinegar by Photometric Ion Chromatography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Yamamoto, Atsushi
× Yamamoto, Atsushi× Matsunaga, Akinobu× Mizukami, Eiichi× Hayakawa, Kazuichi× Miyazaki, Motoichi |
|||||
書誌情報 |
衛生化学 巻 36, 号 4, p. 332-337, 発行日 1990-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0013-273X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00021540 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1248/jhs1956.36.332 | |||||
出版者 | ||||||
出版者 | 日本薬学会 = The Pharmaceutical Society of Japan | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A simultaneous determination method for five organic acids in vinegar has been established by photometric ion chromatography. Both trace components (lactic, gluconic, succinic and pyroglutamic acids) and the major component (acetic acid) in vinegar were separated on a TSK gel IC-Anion-PW column with 0.45 mM o-aminobenzenesulfonic acid aqueous solution as an eluent. Their elutions were detected as positive peaks before the system peak, and a negative peak after that by a UV monitor. The sensitivities of trace components were enhanced by adjusting their elutions close to the system peak. The lowest detection limits were 10μM lactic acid, 5μM gluconic and succinic acids and 3μM pyroglutamic acid, respectively. The only pretreatment necessary was dilution of vinegar 100-fold with the eluent. The results obtained by the proposed method were in good agreement with those by the enzymatic one. | |||||
権利 | ||||||
権利情報 | Copyright © The Pharmaceutical Society of Japan | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.pharm.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jhs1956/-char/ja/ |