WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "5c63c0e3-f6be-4906-8be6-812d63892a94"}, "_deposit": {"created_by": 3, "id": "15196", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "15196"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00015196", "sets": ["1135"]}, "author_link": ["35", "27264"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "224", "bibliographicPageStart": "210", "bibliographicVolumeNumber": "34", "bibliographic_titles": [{"bibliographic_title": "衛生化学 = Eisei kagaku"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Ion chromatography (IC) with conductivity detection, which was introduced in 1975, has become widely used for the simultaneous determination of inorganic and organic ions. On the other hand, photometric ion chromatography (PIC) based on the difference of absorbances of sample and eluent (mobile phase) species has attracted much attention in the recent field of IC, since this technique has potential advantages over IC methods with conductivity detection. This technique which allows IC on a conventional single column HPLC system with an absorbance detector gives compatible sensitivity to conductivity detection. This paper deals mainly with indirect PIC methods performed by both ion exchange and reversedphase modes, where non-UV-absorbing ions are detected as positive and negative peaks by using UV-absorbing ions in the eluent (mobile phase). The features of PIC have been reasonably well known, but it is necessary to understand principles and conditions of PIC for the effective use of this technique. This paper reviews a number of significant reports which deal with the optimisations of separating column, eluent (mobile phase), detection wavelength, sensitivity and restrictions of PIC with its applications. It is also the purpose of this paper to discuss alternative methods and innovations of PIC.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本薬学会 = The Pharmaceutical Society of Japan"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1248/jhs1956.34.210", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.pharm.or.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jhs1956/-char/ja/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © The Pharmaceutical Society of Japan"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00021540", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0013-273X", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "早川, 和一"}], "nameIdentifiers": [{"nameIdentifier": "35", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40115267"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40115267"}, {"nameIdentifier": "40115267", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040115267"}]}, {"creatorNames": [{"creatorName": "宮崎, 元一"}], "nameIdentifiers": [{"nameIdentifier": "27264", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50009164", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50009164"}, {"nameIdentifier": "50009164", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050009164"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "PH-PR-HAYAKAWA-K-210.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "PH-PR-HAYAKAWA-K-210.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/15196/files/PH-PR-HAYAKAWA-K-210.pdf"}, "version_id": "c207e1a2-2889-414a-a9a1-fc6df54e858a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "ion chromatography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "indirect photometric detection", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ion exchange", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reversed-phase", "subitem_subject_scheme": "Other"}, {"subitem_subject": "UV-absorbing ion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "non-UV-absorbing ion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "eluent ion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ion pair reagent", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "吸光度検出イオンクロマトグラフィー", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "吸光度検出イオンクロマトグラフィー"}, {"subitem_title": "Photometric Ion Chromatography", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1135"], "permalink_uri": "http://hdl.handle.net/2297/44916", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-04"}, "publish_date": "2017-10-04", "publish_status": "0", "recid": "15196", "relation": {}, "relation_version_is_last": true, "title": ["吸光度検出イオンクロマトグラフィー"], "weko_shared_id": -1}
吸光度検出イオンクロマトグラフィー
http://hdl.handle.net/2297/44916
http://hdl.handle.net/2297/4491645af04c4-7253-4e2a-b2bd-69ab995ea991
名前 / ファイル | ライセンス | アクション |
---|---|---|
PH-PR-HAYAKAWA-K-210.pdf (1.5 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | 吸光度検出イオンクロマトグラフィー | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Photometric Ion Chromatography | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
早川, 和一
× 早川, 和一× 宮崎, 元一 |
|||||
書誌情報 |
衛生化学 = Eisei kagaku 巻 34, 号 3, p. 210-224, 発行日 1988-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0013-273X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00021540 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1248/jhs1956.34.210 | |||||
出版者 | ||||||
出版者 | 日本薬学会 = The Pharmaceutical Society of Japan | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Ion chromatography (IC) with conductivity detection, which was introduced in 1975, has become widely used for the simultaneous determination of inorganic and organic ions. On the other hand, photometric ion chromatography (PIC) based on the difference of absorbances of sample and eluent (mobile phase) species has attracted much attention in the recent field of IC, since this technique has potential advantages over IC methods with conductivity detection. This technique which allows IC on a conventional single column HPLC system with an absorbance detector gives compatible sensitivity to conductivity detection. This paper deals mainly with indirect PIC methods performed by both ion exchange and reversedphase modes, where non-UV-absorbing ions are detected as positive and negative peaks by using UV-absorbing ions in the eluent (mobile phase). The features of PIC have been reasonably well known, but it is necessary to understand principles and conditions of PIC for the effective use of this technique. This paper reviews a number of significant reports which deal with the optimisations of separating column, eluent (mobile phase), detection wavelength, sensitivity and restrictions of PIC with its applications. It is also the purpose of this paper to discuss alternative methods and innovations of PIC. | |||||
権利 | ||||||
権利情報 | Copyright © The Pharmaceutical Society of Japan | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.pharm.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jhs1956/-char/ja/ |