{"_buckets": {"deposit": "0a55a93e-2b50-49df-834e-2f5fb435d6ac"}, "_deposit": {"created_by": 3, "id": "15645", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "15645"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00015645", "sets": ["1168"]}, "author_link": ["28801", "28802"], "item_7_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1989-11-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "47", "bibliographicPageStart": "44", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "核医学画像診断"}]}]}, "item_7_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "腸骨静脈閉塞症の患者に,腸骨静脈-大腿静脈bypass graft術後の開存の有無を見るためにTc-99m-MAAを用いたRN venographyを行ったところ,bypass graftがきれいに描画されず,閉塞を疑った.翌日に行ったTc-99m-HSAによる骨盤部のRN angiographyでは動脈相で大腿動脈が描画された直後に前記のbypass graftとcollateralsが描画されbypassの開存とA-V shuntが併置されていることが判った.これは,動脈圧のほうが高いので,venous graftが描画されなかったと考えられた.このような病態はRN venographyだけでは誤診されると思われ,RN angiographyの併用が有用である", "subitem_description_type": "Abstract"}]}, "item_7_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "原著論文/症例報告", "subitem_description_type": "Other"}]}, "item_7_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "石川県立中央病院", "subitem_description_type": "Other"}]}, "item_7_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10363063", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0912-4195", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "上野, 恭一"}], "nameIdentifiers": [{"nameIdentifier": "28801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "遠藤, 将光"}], "nameIdentifiers": [{"nameIdentifier": "28802", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "C0000003225-126.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "C0000003225-126.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/15645/files/C0000003225-126.pdf"}, "version_id": "37f7f96d-cb32-454f-b1c5-5742d61d170c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "静脈造影", "subitem_subject_scheme": "Other"}, {"subitem_subject": "大腿静脈", "subitem_subject_scheme": "Other"}, {"subitem_subject": "腸骨静脈(放射線核種診断,外科的療法)バイパス術", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒト", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "腸骨静脈-大腿静脈Bypass Graft RN Venography,RN Angiographyによる評価 症例報告と読影上の問題点", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "腸骨静脈-大腿静脈Bypass Graft RN Venography,RN Angiographyによる評価 症例報告と読影上の問題点"}]}, "item_type_id": "7", "owner": "3", "path": ["1168"], "permalink_uri": "http://hdl.handle.net/2297/4129", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-04"}, "publish_date": "2017-10-04", "publish_status": "0", "recid": "15645", "relation": {}, "relation_version_is_last": true, "title": ["腸骨静脈-大腿静脈Bypass Graft RN Venography,RN Angiographyによる評価 症例報告と読影上の問題点"], "weko_shared_id": -1}
腸骨静脈-大腿静脈Bypass Graft RN Venography,RN Angiographyによる評価 症例報告と読影上の問題点
http://hdl.handle.net/2297/4129
http://hdl.handle.net/2297/4129dfba7984-886a-4d06-8f43-742bbaa2fc5c
名前 / ファイル | ライセンス | アクション |
---|---|---|
C0000003225-126.pdf (2.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | 腸骨静脈-大腿静脈Bypass Graft RN Venography,RN Angiographyによる評価 症例報告と読影上の問題点 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 静脈造影 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 大腿静脈 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 腸骨静脈(放射線核種診断,外科的療法)バイパス術 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ヒト | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
上野, 恭一
× 上野, 恭一× 遠藤, 将光 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 石川県立中央病院 | |||||
書誌情報 |
核医学画像診断 巻 4, 号 2, p. 44-47, 発行日 1989-11-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0912-4195 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10363063 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 腸骨静脈閉塞症の患者に,腸骨静脈-大腿静脈bypass graft術後の開存の有無を見るためにTc-99m-MAAを用いたRN venographyを行ったところ,bypass graftがきれいに描画されず,閉塞を疑った.翌日に行ったTc-99m-HSAによる骨盤部のRN angiographyでは動脈相で大腿動脈が描画された直後に前記のbypass graftとcollateralsが描画されbypassの開存とA-V shuntが併置されていることが判った.これは,動脈圧のほうが高いので,venous graftが描画されなかったと考えられた.このような病態はRN venographyだけでは誤診されると思われ,RN angiographyの併用が有用である | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 原著論文/症例報告 |