{"_buckets": {"deposit": "f2774729-a6d8-4886-a488-54bfa8dc3c9a"}, "_deposit": {"created_by": 3, "id": "17208", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "17208"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00017208", "sets": ["1328"]}, "author_link": ["30882"], "item_7_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-04-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "179", "bibliographicPageStart": "171", "bibliographicVolumeNumber": "110", "bibliographic_titles": [{"bibliographic_title": "金沢大学十全医学会雑誌"}]}]}, "item_7_description_16": {"attribute_name": "その他の識別子", "attribute_value_mlt": [{"subitem_description": "2001268030", "subitem_description_type": "Other"}]}, "item_7_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "ウサギ25羽を用い,硬膜外静脈叢からの出血に対するフィブリン糊硬膜外腔注入法の止血効果及び脊髄に与える影響を検討した.フィブリン糊注入群では非注入群と比較して出血量の有意な減少を認めた.組織学的には,フィブリン糊は硬膜外腔全体に均等に充満していた.フィブリン糊混合液の注入は,脊髄を傷害することなく硬膜外静脈叢を圧迫し,タンポナーデ止血効果を発揮していた", "subitem_description_type": "Abstract"}]}, "item_7_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "原著論文", "subitem_description_type": "Other"}]}, "item_7_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学医整形外科", "subitem_description_type": "Other"}]}, "item_7_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00044397", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0022-7226", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "水野, 勝則"}], "nameIdentifiers": [{"nameIdentifier": "30882", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "C0000002237-006-mizuno.pdf", "filesize": [{"value": "3.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3100000.0, "url": {"label": "C0000002237-006-mizuno.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/17208/files/C0000002237-006-mizuno.pdf"}, "version_id": "b6ecbced-8713-40b9-b7f8-28e753cd2402"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "外科手術", "subitem_subject_scheme": "Other"}, {"subitem_subject": "止血法(実験的)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "脊柱", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Fibrin Tissue Adhesive", "subitem_subject_scheme": "Other"}, {"subitem_subject": "失血-外科(実験的)脊椎切除術(実験的)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ウサギ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "動物", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "脊椎全摘術における硬膜外静脈叢からの出血に対するフィブリン糊の止血効果に関する実験的研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "脊椎全摘術における硬膜外静脈叢からの出血に対するフィブリン糊の止血効果に関する実験的研究"}]}, "item_type_id": "7", "owner": "3", "path": ["1328"], "permalink_uri": "http://hdl.handle.net/2297/4574", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-04"}, "publish_date": "2017-10-04", "publish_status": "0", "recid": "17208", "relation": {}, "relation_version_is_last": true, "title": ["脊椎全摘術における硬膜外静脈叢からの出血に対するフィブリン糊の止血効果に関する実験的研究"], "weko_shared_id": -1}
脊椎全摘術における硬膜外静脈叢からの出血に対するフィブリン糊の止血効果に関する実験的研究
http://hdl.handle.net/2297/4574
http://hdl.handle.net/2297/45744472d00b-2cbb-40d2-895e-d2a3ec7e2fa2
名前 / ファイル | ライセンス | アクション |
---|---|---|
C0000002237-006-mizuno.pdf (3.1 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | 脊椎全摘術における硬膜外静脈叢からの出血に対するフィブリン糊の止血効果に関する実験的研究 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 外科手術 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 止血法(実験的) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 脊柱 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Fibrin Tissue Adhesive | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 失血-外科(実験的)脊椎切除術(実験的) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ウサギ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 動物 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
水野, 勝則
× 水野, 勝則 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医整形外科 | |||||
書誌情報 |
金沢大学十全医学会雑誌 巻 110, 号 2, p. 171-179, 発行日 2001-04-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0022-7226 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00044397 | |||||
その他の識別子 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 2001268030 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | ウサギ25羽を用い,硬膜外静脈叢からの出血に対するフィブリン糊硬膜外腔注入法の止血効果及び脊髄に与える影響を検討した.フィブリン糊注入群では非注入群と比較して出血量の有意な減少を認めた.組織学的には,フィブリン糊は硬膜外腔全体に均等に充満していた.フィブリン糊混合液の注入は,脊髄を傷害することなく硬膜外静脈叢を圧迫し,タンポナーデ止血効果を発揮していた | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 原著論文 |