{"_buckets": {"deposit": "0a206171-f0ce-4bb8-8940-747a6ffc4c5e"}, "_deposit": {"created_by": 3, "id": "17568", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "17568"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00017568", "sets": ["1360"]}, "author_link": ["31155"], "item_7_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-08-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "464", "bibliographicPageStart": "454", "bibliographicVolumeNumber": "104", "bibliographic_titles": [{"bibliographic_title": "金沢大学十全医学会雑誌"}]}]}, "item_7_description_16": {"attribute_name": "その他の識別子", "attribute_value_mlt": [{"subitem_description": "1996133839", "subitem_description_type": "Other"}]}, "item_7_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "雑種成熟イヌ15匹を使用し,電気刺激した骨格筋の収縮力を利用した右心又は左心機能補助の実験的検討を行った. 1)側副血行を温存し骨格筋の収縮力を最大限に利用でる新型の直線牽引式駆動装置を考案・作成した.これを右心室自由壁また左心室心尖部に置換したダイナミックパッチの駆動源とすることで,骨格筋の電気刺激により有効な心補助効果が得られた. 2)動物7匹を用いた骨格筋駆動右室ダイナミックパッチの実験にて,右室収縮期圧は41.0mmHgから55.6mmHgへ有意に上昇し,平均右房圧は14.3mmHgから9.57mmHgへ有意に低下し,有効な右心機能補助効果が得られた.大動脈収縮期圧は78.1mmHgから91.3mmHgへ,AoFは0.73l/minから0.97l/minへと有意に上昇し,心機能全体としての補助も有効であった. 3)動物8匹を用いた骨格筋駆動左室ダイナミックパッチの実験にても有効な左心機能補助効果が得られた", "subitem_description_type": "Abstract"}]}, "item_7_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学 医 第1外科", "subitem_description_type": "Other"}]}, "item_7_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "金沢大学十全医学会"}]}, "item_7_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00044397", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0022-7226", "subitem_source_identifier_type": "ISSN"}]}, "item_7_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "高橋, 政夫"}], "nameIdentifiers": [{"nameIdentifier": "31155", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70332666", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70332666"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-04"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AN00044397-104-043.pdf", "filesize": [{"value": "2.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2100000.0, "url": {"label": "AN00044397-104-043.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/17568/files/AN00044397-104-043.pdf"}, "version_id": "b094e22e-d226-489b-b285-bfb56e8b6bcd"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "筋骨格系生理学", "subitem_subject_scheme": "Other"}, {"subitem_subject": "心機能検査", "subitem_subject_scheme": "Other"}, {"subitem_subject": "心臓補助機器", "subitem_subject_scheme": "Other"}, {"subitem_subject": "骨格筋", "subitem_subject_scheme": "Other"}, {"subitem_subject": "イヌ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "動物", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "骨格筋駆動ダイナミックパッチによる心機能補助効果に関する基礎的研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "骨格筋駆動ダイナミックパッチによる心機能補助効果に関する基礎的研究"}]}, "item_type_id": "7", "owner": "3", "path": ["1360"], "permalink_uri": "http://hdl.handle.net/2297/9148", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-04"}, "publish_date": "2017-10-04", "publish_status": "0", "recid": "17568", "relation": {}, "relation_version_is_last": true, "title": ["骨格筋駆動ダイナミックパッチによる心機能補助効果に関する基礎的研究"], "weko_shared_id": -1}
骨格筋駆動ダイナミックパッチによる心機能補助効果に関する基礎的研究
http://hdl.handle.net/2297/9148
http://hdl.handle.net/2297/914876a69cef-ccd0-49d6-bc15-57a6b01108dd
名前 / ファイル | ライセンス | アクション |
---|---|---|
AN00044397-104-043.pdf (2.1 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-04 | |||||
タイトル | ||||||
タイトル | 骨格筋駆動ダイナミックパッチによる心機能補助効果に関する基礎的研究 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 筋骨格系生理学 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 心機能検査 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 心臓補助機器 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 骨格筋 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | イヌ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 動物 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
高橋, 政夫
× 高橋, 政夫 |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学 医 第1外科 | |||||
書誌情報 |
金沢大学十全医学会雑誌 巻 104, 号 4, p. 454-464, 発行日 1995-08-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0022-7226 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00044397 | |||||
その他の識別子 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 1996133839 | |||||
出版者 | ||||||
出版者 | 金沢大学十全医学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 雑種成熟イヌ15匹を使用し,電気刺激した骨格筋の収縮力を利用した右心又は左心機能補助の実験的検討を行った. 1)側副血行を温存し骨格筋の収縮力を最大限に利用でる新型の直線牽引式駆動装置を考案・作成した.これを右心室自由壁また左心室心尖部に置換したダイナミックパッチの駆動源とすることで,骨格筋の電気刺激により有効な心補助効果が得られた. 2)動物7匹を用いた骨格筋駆動右室ダイナミックパッチの実験にて,右室収縮期圧は41.0mmHgから55.6mmHgへ有意に上昇し,平均右房圧は14.3mmHgから9.57mmHgへ有意に低下し,有効な右心機能補助効果が得られた.大動脈収縮期圧は78.1mmHgから91.3mmHgへ,AoFは0.73l/minから0.97l/minへと有意に上昇し,心機能全体としての補助も有効であった. 3)動物8匹を用いた骨格筋駆動左室ダイナミックパッチの実験にても有効な左心機能補助効果が得られた | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |