{"_buckets": {"deposit": "687575f1-5d24-488f-bcbb-05530bdeb6f3"}, "_deposit": {"created_by": 3, "id": "26856", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "26856"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00026856", "sets": ["1763"]}, "author_link": ["45386", "599", "1059", "463", "320", "489", "45385", "115", "45387", "28069"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-04-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "255", "bibliographicPageStart": "248", "bibliographicVolumeNumber": "29", "bibliographic_titles": [{"bibliographic_title": "Annals of Nuclear Medicine"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objective: Although SPECT/CT systems have been used for sentinel lymph node (SLN) imaging, few studies have focused on optimization of attenuation correction (AC) and scatter correction (SC). While SLNs could be detected in conventional planar images, they sometimes do not appear in SPECT/CT images. The purpose of this study was to investigate the optimal AC and SC and to improve the detectability of SLNs in examinations using SPECT/CT systems.Materials and methods: The study group consisted of 56 female patients with breast cancer. In SPECT/CT imaging, four kinds of images were created with and without AC and SC; namely, AC−SC−, AC+SC−, AC−SC+ and AC+SC+. Five nuclear medicine physicians interpreted the planar and SPECT/CT images with five grades of confidence levels (1–5). The detection rate was calculated as the number of patients whose average confidence levels of interpretation were more than 4, divided by the total number of patients.Results: The confidence level of interpretation and the detection rate provided by the planar images were 4.76 ± 0.49 and 94.6 %, respectively. In SPECT/CT imaging, the AC+SC− provided the best detection rate (confidence level of interpretation, 4.81 ± 0.38; detection rate, 98.2 %), followed by the AC−SC− (4.70 ± 0.55, 89.3 %), and the AC−SC+ (4.39 ± 1.2, 78.6 %). The lowest values were obtained for the AC+SC+ (4.36 ± 1.22, 78.6 %). Regarding the confidence levels of interpretation, significant differences were observed between AC+SC− and AC−SC−, AC+SC− and AC+SC+, AC+SC− and AC−SC+, and between planar images and AC+SC+ (P = 0.0021, 0.0009, 0.0013, and 0.0056, respectively).Conclusions: When SPECT/CT was used, AC improved the detection of SLNs. SC caused disappearance of a faint SLN in some cases and should not be performed.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer-Verlag"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s12149-014-0939-1", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10708017", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0914-7187", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoneyama, Hiroto"}], "nameIdentifiers": [{"nameIdentifier": "45385", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsushima, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "45386", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Onoguchi, Masahisa"}], "nameIdentifiers": [{"nameIdentifier": "1059", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30283102", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030283102"}]}, {"creatorNames": [{"creatorName": "Konishi, Takahiro"}], "nameIdentifiers": [{"nameIdentifier": "45387", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Kenichi"}], "nameIdentifiers": [{"nameIdentifier": "320", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=00167545"}, {"nameIdentifier": "00167545", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000000167545"}]}, {"creatorNames": [{"creatorName": "Matsuo, Shinro"}], "nameIdentifiers": [{"nameIdentifier": "599", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30359773"}, {"nameIdentifier": "30359773", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030359773"}]}, {"creatorNames": [{"creatorName": "Kayano, Daiki"}], "nameIdentifiers": [{"nameIdentifier": "463", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10547152", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10547152"}, {"nameIdentifier": "10547152", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010547152"}]}, {"creatorNames": [{"creatorName": "Wakabayashi, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "489", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60622818", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60622818"}, {"nameIdentifier": "60622818", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060622818"}]}, {"creatorNames": [{"creatorName": "Inaki, Anri"}], "nameIdentifiers": [{"nameIdentifier": "28069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40645131", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40645131"}, {"nameIdentifier": "40645131", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040645131"}]}, {"creatorNames": [{"creatorName": "Kinuya, Seigo"}], "nameIdentifiers": [{"nameIdentifier": "115", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20281024"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=20281024"}, {"nameIdentifier": "20281024", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020281024"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "HO-PR-YONEYAMA-H-248.pdf", "filesize": [{"value": "746.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 746700.0, "url": {"label": "HO-PR-YONEYAMA-H-248.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/26856/files/HO-PR-YONEYAMA-H-248.pdf"}, "version_id": "32c0ac11-3e24-4e28-871c-b1cedc72bb96"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Attenuation correction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Breast cancer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Scatter correction", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Sentinel lymph node", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SPECT/CT", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems"}]}, "item_type_id": "4", "owner": "3", "path": ["1763"], "permalink_uri": "http://hdl.handle.net/2297/40603", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-05"}, "publish_date": "2017-10-05", "publish_status": "0", "recid": "26856", "relation": {}, "relation_version_is_last": true, "title": ["Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems"], "weko_shared_id": -1}
Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems
http://hdl.handle.net/2297/40603
http://hdl.handle.net/2297/40603dfbe7d17-3b57-4721-8d05-d4b9a182a07d
名前 / ファイル | ライセンス | アクション |
---|---|---|
HO-PR-YONEYAMA-H-248.pdf (746.7 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-05 | |||||
タイトル | ||||||
タイトル | Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Yoneyama, Hiroto
× Yoneyama, Hiroto× Tsushima, Hiroyuki× Onoguchi, Masahisa× Konishi, Takahiro× Nakajima, Kenichi× Matsuo, Shinro× Kayano, Daiki× Wakabayashi, Hiroshi× Inaki, Anri× Kinuya, Seigo |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 29, 号 3, p. 248-255, 発行日 2015-04-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10708017 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-014-0939-1 | |||||
出版者 | ||||||
出版者 | Springer-Verlag | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: Although SPECT/CT systems have been used for sentinel lymph node (SLN) imaging, few studies have focused on optimization of attenuation correction (AC) and scatter correction (SC). While SLNs could be detected in conventional planar images, they sometimes do not appear in SPECT/CT images. The purpose of this study was to investigate the optimal AC and SC and to improve the detectability of SLNs in examinations using SPECT/CT systems.Materials and methods: The study group consisted of 56 female patients with breast cancer. In SPECT/CT imaging, four kinds of images were created with and without AC and SC; namely, AC−SC−, AC+SC−, AC−SC+ and AC+SC+. Five nuclear medicine physicians interpreted the planar and SPECT/CT images with five grades of confidence levels (1–5). The detection rate was calculated as the number of patients whose average confidence levels of interpretation were more than 4, divided by the total number of patients.Results: The confidence level of interpretation and the detection rate provided by the planar images were 4.76 ± 0.49 and 94.6 %, respectively. In SPECT/CT imaging, the AC+SC− provided the best detection rate (confidence level of interpretation, 4.81 ± 0.38; detection rate, 98.2 %), followed by the AC−SC− (4.70 ± 0.55, 89.3 %), and the AC−SC+ (4.39 ± 1.2, 78.6 %). The lowest values were obtained for the AC+SC+ (4.36 ± 1.22, 78.6 %). Regarding the confidence levels of interpretation, significant differences were observed between AC+SC− and AC−SC−, AC+SC− and AC+SC+, AC+SC− and AC−SC+, and between planar images and AC+SC+ (P = 0.0021, 0.0009, 0.0013, and 0.0056, respectively).Conclusions: When SPECT/CT was used, AC improved the detection of SLNs. SC caused disappearance of a faint SLN in some cases and should not be performed. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |