{"_buckets": {"deposit": "471c8327-753f-4f34-868e-f3d617ec1a37"}, "_deposit": {"created_by": 3, "id": "26914", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "26914"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00026914", "sets": ["1763"]}, "author_link": ["704", "45509", "45510", "582", "11684", "538", "11685"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "60", "bibliographicPageStart": "56", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "Journal of Neuroendovascular Therapy = 脳神経血管内治療"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "【目的】左総頚動脈(CCA)狭窄症に対するステント留置術の際にガイディングシースの保持を右上腕動脈経由のGooseNeck Snareで行った症例を報告する.【症例】70歳,男性.一過性の右片麻痺で発見された症候性左CCA狭窄症に対してステント留置術を行った.狭窄病変とCCA起始部の距離が短いためガイディングシースを十分遠位まで挿入できなかった.そのため右上腕動脈経由のGooseNeck Snareでガイディングシースを保持してステント留置術を施行し得た.【結論】上腕動脈経由のGooseNeck Snareによる左CCAのガイディングシースの保持は有用であった.Objective: We report a case of left common carotid artery stenting in which the guide sheath was held in place by a GooseNeck Snare inserted from the right brachial artery. Case presentation: A 70-year-old man presented with transient right hemiparesis and symptomatic left common carotid artery stenosis. During carotid artery stenting, we were unable to insert the guide sheath into the distal site of the carotid artery because of the short distance between the origin of the carotid artery and the stenotic lesion. By holding the guide sheath in place using the GooseNeck Snare inserted from the right brachial artery, stenting was performed successfully. Conclusion: Transbrachial GooseNeck Snare was useful for stabilization of the guide sheath during left common carotid artery stenting.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本脳神経血管内治療学会 = The Japanese Society for Neuroendovascular Therapy"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.5797/jnet.6.56", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jnet/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsnet.umin.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2014 The Japanese Society for Neuroendovascular Therapy 日本脳神経血管内治療学会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA1229439X", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1882-4072", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "見崎, 孝一"}], "nameIdentifiers": [{"nameIdentifier": "582", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20507082", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20507082"}, {"nameIdentifier": "20507082", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=20507082"}, {"nameIdentifier": "20507082", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020507082"}]}, {"creatorNames": [{"creatorName": "内山, 尚之"}], "nameIdentifiers": [{"nameIdentifier": "538", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80293364"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80293364"}, {"nameIdentifier": "80293364", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080293364"}]}, {"creatorNames": [{"creatorName": "毛利, 正直"}], "nameIdentifiers": [{"nameIdentifier": "704", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60377413", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60377413"}, {"nameIdentifier": "60377413", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060377413"}]}, {"creatorNames": [{"creatorName": "福井, 一生"}], "nameIdentifiers": [{"nameIdentifier": "45509", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "南部, 育"}], "nameIdentifiers": [{"nameIdentifier": "45510", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80735465", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80735465"}]}, {"creatorNames": [{"creatorName": "林, 裕"}], "nameIdentifiers": [{"nameIdentifier": "11685", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90262568", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=90262568"}, {"nameIdentifier": "90262568", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090262568"}]}, {"creatorNames": [{"creatorName": "濱田, 潤一郎"}], "nameIdentifiers": [{"nameIdentifier": "11684", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40253752", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40253752"}, {"nameIdentifier": "40253752", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040253752"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "HO-PR-MISAKI-K-56.pdf", "filesize": [{"value": "901.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 901800.0, "url": {"label": "HO-PR-MISAKI-K-56.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/26914/files/HO-PR-MISAKI-K-56.pdf"}, "version_id": "770e2cf9-9779-44f3-b223-f9c0d1a9de7d"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "common carotid artery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "GooseNeck Snare", "subitem_subject_scheme": "Other"}, {"subitem_subject": "guiding sheath", "subitem_subject_scheme": "Other"}, {"subitem_subject": "stenting", "subitem_subject_scheme": "Other"}, {"subitem_subject": "transbrachial", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "左総頚動脈ステント留置術におけるガイディングシース保持のためのGooseNeck Snareの使用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "左総頚動脈ステント留置術におけるガイディングシース保持のためのGooseNeck Snareの使用"}, {"subitem_title": "Stabilizing the guiding sheath during left common carotid artery stenting by using a GooseNeck Snare: technical note", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["1763"], "permalink_uri": "http://hdl.handle.net/2297/43229", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-05"}, "publish_date": "2017-10-05", "publish_status": "0", "recid": "26914", "relation": {}, "relation_version_is_last": true, "title": ["左総頚動脈ステント留置術におけるガイディングシース保持のためのGooseNeck Snareの使用"], "weko_shared_id": -1}
左総頚動脈ステント留置術におけるガイディングシース保持のためのGooseNeck Snareの使用
http://hdl.handle.net/2297/43229
http://hdl.handle.net/2297/43229ead11507-f63b-4f0d-ba87-39a8f6fbebd2
名前 / ファイル | ライセンス | アクション |
---|---|---|
HO-PR-MISAKI-K-56.pdf (901.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-05 | |||||
タイトル | ||||||
タイトル | 左総頚動脈ステント留置術におけるガイディングシース保持のためのGooseNeck Snareの使用 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Stabilizing the guiding sheath during left common carotid artery stenting by using a GooseNeck Snare: technical note | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
見崎, 孝一
× 見崎, 孝一× 内山, 尚之× 毛利, 正直× 福井, 一生× 南部, 育× 林, 裕× 濱田, 潤一郎 |
|||||
書誌情報 |
Journal of Neuroendovascular Therapy = 脳神経血管内治療 巻 6, 号 1, p. 56-60, 発行日 2012-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1882-4072 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA1229439X | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.5797/jnet.6.56 | |||||
出版者 | ||||||
出版者 | 日本脳神経血管内治療学会 = The Japanese Society for Neuroendovascular Therapy | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 【目的】左総頚動脈(CCA)狭窄症に対するステント留置術の際にガイディングシースの保持を右上腕動脈経由のGooseNeck Snareで行った症例を報告する.【症例】70歳,男性.一過性の右片麻痺で発見された症候性左CCA狭窄症に対してステント留置術を行った.狭窄病変とCCA起始部の距離が短いためガイディングシースを十分遠位まで挿入できなかった.そのため右上腕動脈経由のGooseNeck Snareでガイディングシースを保持してステント留置術を施行し得た.【結論】上腕動脈経由のGooseNeck Snareによる左CCAのガイディングシースの保持は有用であった.Objective: We report a case of left common carotid artery stenting in which the guide sheath was held in place by a GooseNeck Snare inserted from the right brachial artery. Case presentation: A 70-year-old man presented with transient right hemiparesis and symptomatic left common carotid artery stenosis. During carotid artery stenting, we were unable to insert the guide sheath into the distal site of the carotid artery because of the short distance between the origin of the carotid artery and the stenotic lesion. By holding the guide sheath in place using the GooseNeck Snare inserted from the right brachial artery, stenting was performed successfully. Conclusion: Transbrachial GooseNeck Snare was useful for stabilization of the guide sheath during left common carotid artery stenting. | |||||
権利 | ||||||
権利情報 | Copyright © 2014 The Japanese Society for Neuroendovascular Therapy 日本脳神経血管内治療学会 | |||||