{"_buckets": {"deposit": "d0880c2c-b460-4079-8998-49bec1895776"}, "_deposit": {"created_by": 18, "id": "42559", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "42559"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00042559", "sets": ["936"]}, "author_link": ["67852", "67853", "67854", "67856", "67857", "67855"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "109", "bibliographicPageStart": "106", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Journal of the Japan Society of Applied Electromagnetics and Mechanics = 日本AEM学会誌"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The main aim of this article is to present the possibility to estimate the content density of magnetic fluid in various shape cavities by SV-GMR needle type probe. Changes caused by the shape and amount of ferrite included in cavity were examined. Analytical model and numerical calculation were performed to confirm these results. We assume that if the signal changes are linearly dependent on magnetic permeability of sample and with known shape ratio it is possible to estimate the amount of the iron consisted in the sample.", "subitem_description_type": "Abstract"}]}, "item_10001_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Special Issue of the Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM10)", "subitem_description_type": "Other"}]}, "item_10001_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00048913", "subitem_identifier_reg_type": "JaLC"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本AEM学会 = The Japan Society of Applied Electromagnetics "}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://www.jstage.jst.go.jp/browse/jsaem/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jsaem/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "http://www.jsaem.gr.jp/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsaem.gr.jp/", "subitem_relation_type_select": "URI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 日本AEM学会 The Japan Society of Applied Electromagnetics and Mechanics"}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452 ", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "山田, 外史"}], "nameIdentifiers": [{"nameIdentifier": "67852", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柿川, 真紀子"}], "nameIdentifiers": [{"nameIdentifier": "67853", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "R.G., Haraszczuk", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67854", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sotoshi, Yamada", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67855", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Makiko, Kakikawa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67856", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "C.P., Gooneratne", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "67857", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-11-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-310.pdf", "filesize": [{"value": "939.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_6", "mimetype": "application/pdf", "size": 939400.0, "url": {"label": "TE-PR-YAMADA-S-310.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/42559/files/TE-PR-YAMADA-S-310.pdf"}, "version_id": "6f0b7fdb-b942-488d-af9f-2fec45385fe8"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "GMR sensor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Demagnetizing factor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Magnetic nanoparticles", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Lee Whiting coil", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe"}]}, "item_type_id": "10001", "owner": "18", "path": ["936"], "permalink_uri": "https://doi.org/10.24517/00048913", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-11-16"}, "publish_date": "2017-11-16", "publish_status": "0", "recid": "42559", "relation": {}, "relation_version_is_last": true, "title": ["Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe"], "weko_shared_id": -1}
Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe
https://doi.org/10.24517/00048913
https://doi.org/10.24517/0004891306b55170-4106-4679-ac65-8073127c3f37
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-310.pdf (939.4 kB)
|
Item type | 学術雑誌論文 / Journal Article_default(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-16 | |||||
タイトル | ||||||
タイトル | Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | GMR sensor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Demagnetizing factor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Magnetic nanoparticles | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Lee Whiting coil | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.24517/00048913 | |||||
ID登録タイプ | JaLC | |||||
著者 |
山田, 外史
× 山田, 外史× 柿川, 真紀子× R.G., Haraszczuk× Sotoshi, Yamada× Makiko, Kakikawa× C.P., Gooneratne |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The main aim of this article is to present the possibility to estimate the content density of magnetic fluid in various shape cavities by SV-GMR needle type probe. Changes caused by the shape and amount of ferrite included in cavity were examined. Analytical model and numerical calculation were performed to confirm these results. We assume that if the signal changes are linearly dependent on magnetic permeability of sample and with known shape ratio it is possible to estimate the amount of the iron consisted in the sample. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Special Issue of the Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM10) | |||||
書誌情報 |
Journal of the Japan Society of Applied Electromagnetics and Mechanics = 日本AEM学会誌 巻 19, 号 3, p. 106-109, 発行日 2011 |
|||||
出版者 | ||||||
出版者 | 日本AEM学会 = The Japan Society of Applied Electromagnetics | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0919-4452 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10457520 | |||||
権利 | ||||||
権利情報 | Copyright © 日本AEM学会 The Japan Society of Applied Electromagnetics and Mechanics | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jsaem/ | |||||
関連名称 | https://www.jstage.jst.go.jp/browse/jsaem/ | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsaem.gr.jp/ | |||||
関連名称 | http://www.jsaem.gr.jp/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |