WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "0cfd7a6d-c051-44fa-82ea-e7a2335cfa83"}, "_deposit": {"created_by": 18, "id": "48347", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "48347"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00048347", "sets": ["2815"]}, "author_link": ["296", "79669"], "item_9_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-06-16", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "4p.", "bibliographicVolumeNumber": "2016-04-01 - 2019-03-31", "bibliographic_titles": [{"bibliographic_title": "平成30(2018)年度 科学研究費補助金 基盤研究(C) 研究成果報告書"}, {"bibliographic_title": "2018 Fiscal Year Final Research Report", "bibliographic_titleLang": "en"}]}]}, "item_9_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Goto, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "79669", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30361976", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30361976"}]}]}, "item_9_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "宇宙の利活用の拡大に伴い、衛星を使ったサービス(通信、放送、測位、遠隔計測など)で利用される電波に対して大きな影響を及ぼす電離圏プラズマ(荷電粒子)の監視の重要性が高まっている。電離圏は、シンチレーションや遅延など電波伝搬に最も大きな影響を及ぼす領域であるが、その組成や密度分布は太陽活動や地磁気活動と深く関わっており複雑なパラメータ依存性をもっている。本研究では、従来の高価な2周波受信機ではなく、民生用の安価な1周波受信機を使って電離層のプラズマ密度を測定する方法を確立した。 ", "subitem_description_type": "Abstract"}, {"subitem_description": "Continuous monitoring of ionospheric total electron content (TEC) using networks of GNSS (global navigation satellite system) ground stations has been conducted in many countries since such networks make it possible to measure the TEC distributions in high spatial and temporal resolutions. Most of the GNSS networks are, however, built in mid latitude regions. In order to understand dynamics of ionospheric plasma at equatorial regions in more detail, it is effective to expand the observation network in low latitudes. The TEC observations are generally realized by measuring two frequency signals from GNSS satellites because only ionospheric delay depends on the frequency in ranging errors. However, multi-frequency receivers are not consumer products and their costs are much higher than those of single frequency receivers. In this study, ionospheric TEC observation method using a single frequency GPS receiver was developed. ", "subitem_description_type": "Abstract"}]}, "item_9_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "研究課題/領域番号:16K06383, 研究期間(年度):2016-04-01 - 2019-03-31", "subitem_description_type": "Other"}, {"subitem_description": "出典:研究課題「地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究」課題番号16K06383\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所)) \n(https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/)を加工して作成", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00054669", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_publisher_17": {"attribute_name": "公開者", "attribute_value_mlt": [{"subitem_publisher": "金沢大学理工研究域電子情報通信学系"}]}, "item_9_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/search/?qm=30361976"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/search/?qm=30361976", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K06383/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K06383/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/", "subitem_relation_type_select": "URI"}}]}, "item_9_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "後藤, 由貴"}], "nameIdentifiers": [{"nameIdentifier": "296", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30361976", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=30361976"}, {"nameIdentifier": "30361976", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=30361976"}, {"nameIdentifier": "30361976", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000030361976"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-04-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-GOTO-Y-kaken 2019-4p.pdf", "filesize": [{"value": "249.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 249700.0, "url": {"label": "TE-PR-GOTO-Y-kaken 2019-4p.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/48347/files/TE-PR-GOTO-Y-kaken 2019-4p.pdf"}, "version_id": "36ecbafd-e0c1-4393-b77b-e676496ea981"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "電離層プラズマ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "TEC計測", "subitem_subject_scheme": "Other"}, {"subitem_subject": "GPS観測網", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究"}, {"subitem_title": "Study on Ionospheric TEC Measurement by Single Frequency GPS Receivers", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "18", "path": ["2815"], "permalink_uri": "https://doi.org/10.24517/00054669", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-04-24"}, "publish_date": "2020-04-24", "publish_status": "0", "recid": "48347", "relation": {}, "relation_version_is_last": true, "title": ["地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究"], "weko_shared_id": -1}
地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究
https://doi.org/10.24517/00054669
https://doi.org/10.24517/000546698b06fbc6-b1a4-455f-bbf5-30e301cac359
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-GOTO-Y-kaken 2019-4p.pdf (249.7 kB)
|
Item type | 報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-04-24 | |||||
タイトル | ||||||
タイトル | 地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Study on Ionospheric TEC Measurement by Single Frequency GPS Receivers | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
ID登録 | ||||||
ID登録 | 10.24517/00054669 | |||||
ID登録タイプ | JaLC | |||||
著者別表示 |
Goto, Yoshitaka
× Goto, Yoshitaka |
|||||
書誌情報 |
平成30(2018)年度 科学研究費補助金 基盤研究(C) 研究成果報告書 en : 2018 Fiscal Year Final Research Report 巻 2016-04-01 - 2019-03-31, p. 4p., 発行日 2019-06-16 |
|||||
出版者 | ||||||
出版者 | 金沢大学理工研究域電子情報通信学系 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 宇宙の利活用の拡大に伴い、衛星を使ったサービス(通信、放送、測位、遠隔計測など)で利用される電波に対して大きな影響を及ぼす電離圏プラズマ(荷電粒子)の監視の重要性が高まっている。電離圏は、シンチレーションや遅延など電波伝搬に最も大きな影響を及ぼす領域であるが、その組成や密度分布は太陽活動や地磁気活動と深く関わっており複雑なパラメータ依存性をもっている。本研究では、従来の高価な2周波受信機ではなく、民生用の安価な1周波受信機を使って電離層のプラズマ密度を測定する方法を確立した。 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Continuous monitoring of ionospheric total electron content (TEC) using networks of GNSS (global navigation satellite system) ground stations has been conducted in many countries since such networks make it possible to measure the TEC distributions in high spatial and temporal resolutions. Most of the GNSS networks are, however, built in mid latitude regions. In order to understand dynamics of ionospheric plasma at equatorial regions in more detail, it is effective to expand the observation network in low latitudes. The TEC observations are generally realized by measuring two frequency signals from GNSS satellites because only ionospheric delay depends on the frequency in ranging errors. However, multi-frequency receivers are not consumer products and their costs are much higher than those of single frequency receivers. In this study, ionospheric TEC observation method using a single frequency GPS receiver was developed. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 研究課題/領域番号:16K06383, 研究期間(年度):2016-04-01 - 2019-03-31 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 出典:研究課題「地球周辺プラズマ監視のための1周波GPS受信機連携型観測装置の開発に関する研究」課題番号16K06383 (KAKEN:科学研究費助成事業データベース(国立情報学研究所)) (https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/)を加工して作成 |
|||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/search/?qm=30361976 | |||||
関連名称 | https://kaken.nii.ac.jp/search/?qm=30361976 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K06383/ | |||||
関連名称 | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-16K06383/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/ | |||||
関連名称 | https://kaken.nii.ac.jp/report/KAKENHI-PROJECT-16K06383/16K06383seika/ |