{"_buckets": {"deposit": "094b8115-3244-4c5d-aace-1418f3498a69"}, "_deposit": {"created_by": 18, "id": "52376", "owners": [18], "pid": {"revision_id": 0, "type": "depid", "value": "52376"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00052376", "sets": ["2819"]}, "author_link": ["10059", "10974"], "item_9_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-05-21", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "5p.", "bibliographicVolumeNumber": "2012-04-01 – 2015-03-31", "bibliographic_titles": [{"bibliographic_title": "平成26(2014)年度 科学研究費補助金 若手研究(A) 研究成果報告書"}, {"bibliographic_title": "2014 Fiscal Year Final Research Report", "bibliographic_titleLang": "en"}]}]}, "item_9_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamakoshi, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "10059", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}]}]}, "item_9_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "本課題は,近年大きな社会問題となっている熱中症や日常活動中の健康管理等に焦点を当て,深部体温(鼓膜温)・心拍などを「耳介密閉型耳栓」から取得し,スマートフォンと連携させて「熱中症対策や自己健康管理」に利用でき,イヤホンとしても共用可能な「スマートイヤーモニター」の開発を目標した研究である。研究期間では,熱中症発症による事故が深刻な問題となっている条件下においてそれを検知・警告できるような新たな深部体温計測システムを考案・開発・検証,心機能情報を計測するための外耳道における適切な計測部位の検討,体動の検討,およびiPhone用アプリ(iPhysioMeter)の開発を行った。", "subitem_description_type": "Abstract"}, {"subitem_description": "The final goal of this study was to develop a smart ear monitor for detecting heat illness and/or stress in daily life. In order to accomplish this study, First, we have developed a new methodology for detecting heat illness based on continuous tympanic thermometry in serious hot condition. Second, we have searched for the appropriate part of ear-canal to obtain cardiac beating and normalized pulse volume as a indicator of sympathetic nerve activity. Third, we have developed a new smartphone application named \"iPhysioMeter: http://iphysiometer.com/app/\", which can measure and easily monitor the physiological variables. These results can yield to the smart ear monitor in the near future.", "subitem_description_type": "Abstract"}]}, "item_9_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "研究課題/領域番号:24680063, 研究期間(年度):2012-04-01 – 2015-03-31", "subitem_description_type": "Other"}, {"subitem_description": "出典:研究課題「熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究」課題番号24680063\n(KAKEN:科学研究費助成事業データベース(国立情報学研究所))\n(https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/)を加工して作成", "subitem_description_type": "Other"}]}, "item_9_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "福岡工業大学 / 金沢大学", "subitem_description_type": "Other"}]}, "item_9_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00058670", "subitem_identifier_reg_type": "JaLC"}]}, "item_9_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/ja/search/?kw=70444205"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/ja/search/?kw=70444205", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-24680063/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-24680063/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_name": [{"subitem_relation_name_text": "https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/", "subitem_relation_type_select": "URI"}}]}, "item_9_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "山越, 健弘"}], "nameIdentifiers": [{"nameIdentifier": "10974", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070444205"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-07-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMAKOSHI-T-kaken 2015-5p.pdf", "filesize": [{"value": "349.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 349800.0, "url": {"label": "TE-PR-YAMAKOSHI-T-kaken 2015-5p.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/52376/files/TE-PR-YAMAKOSHI-T-kaken 2015-5p.pdf"}, "version_id": "db2e93bc-1848-4f9b-b295-15b48df6cf04"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "生体情報計測", "subitem_subject_scheme": "Other"}, {"subitem_subject": "生体情報解析", "subitem_subject_scheme": "Other"}, {"subitem_subject": "健康・福祉工学", "subitem_subject_scheme": "Other"}, {"subitem_subject": "スマートセンサ情報システム", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電子デバイス・機器", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究"}, {"subitem_title": "Developments of human support ear monitoring system for daily life and heat illness", "subitem_title_language": "en"}]}, "item_type_id": "9", "owner": "18", "path": ["2819"], "permalink_uri": "https://doi.org/10.24517/00058670", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-07-16"}, "publish_date": "2020-07-16", "publish_status": "0", "recid": "52376", "relation": {}, "relation_version_is_last": true, "title": ["熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究"], "weko_shared_id": -1}
熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究
https://doi.org/10.24517/00058670
https://doi.org/10.24517/000586709966faf6-be7a-4941-b89c-d65706755694
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMAKOSHI-T-kaken 2015-5p.pdf (349.8 kB)
|
Item type | 報告書 / Research Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-16 | |||||
タイトル | ||||||
タイトル | 熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Developments of human support ear monitoring system for daily life and heat illness | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||
資源タイプ | research report | |||||
ID登録 | ||||||
ID登録 | 10.24517/00058670 | |||||
ID登録タイプ | JaLC | |||||
著者 |
山越, 健弘
× 山越, 健弘 |
|||||
著者別表示 |
Yamakoshi, Takehiro
× Yamakoshi, Takehiro |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 福岡工業大学 / 金沢大学 | |||||
書誌情報 |
平成26(2014)年度 科学研究費補助金 若手研究(A) 研究成果報告書 en : 2014 Fiscal Year Final Research Report 巻 2012-04-01 – 2015-03-31, p. 5p., 発行日 2015-05-21 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 本課題は,近年大きな社会問題となっている熱中症や日常活動中の健康管理等に焦点を当て,深部体温(鼓膜温)・心拍などを「耳介密閉型耳栓」から取得し,スマートフォンと連携させて「熱中症対策や自己健康管理」に利用でき,イヤホンとしても共用可能な「スマートイヤーモニター」の開発を目標した研究である。研究期間では,熱中症発症による事故が深刻な問題となっている条件下においてそれを検知・警告できるような新たな深部体温計測システムを考案・開発・検証,心機能情報を計測するための外耳道における適切な計測部位の検討,体動の検討,およびiPhone用アプリ(iPhysioMeter)の開発を行った。 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The final goal of this study was to develop a smart ear monitor for detecting heat illness and/or stress in daily life. In order to accomplish this study, First, we have developed a new methodology for detecting heat illness based on continuous tympanic thermometry in serious hot condition. Second, we have searched for the appropriate part of ear-canal to obtain cardiac beating and normalized pulse volume as a indicator of sympathetic nerve activity. Third, we have developed a new smartphone application named "iPhysioMeter: http://iphysiometer.com/app/", which can measure and easily monitor the physiological variables. These results can yield to the smart ear monitor in the near future. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 研究課題/領域番号:24680063, 研究期間(年度):2012-04-01 – 2015-03-31 | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 出典:研究課題「熱中症対策・健康管理を目指した生体情報スマートイヤーモニターの先駆的開発研究」課題番号24680063 (KAKEN:科学研究費助成事業データベース(国立情報学研究所)) (https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/)を加工して作成 |
|||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/ja/search/?kw=70444205 | |||||
関連名称 | https://kaken.nii.ac.jp/ja/search/?kw=70444205 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-24680063/ | |||||
関連名称 | https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-24680063/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/ | |||||
関連名称 | https://kaken.nii.ac.jp/ja/report/KAKENHI-PROJECT-24680063/24680063seika/ |