{"_buckets": {"deposit": "8f748db7-0eda-48b3-9282-d9d97bdcc37b"}, "_deposit": {"created_by": 3, "id": "58947", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "58947"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00058947", "sets": ["4047"]}, "author_link": ["103586", "103589", "31426", "495", "103588", "84799"], "item_7_alternative_title_2": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "人工呼吸依存患者における肺コンプライアンス低下の要因について:追跡研究"}]}, "item_7_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2022-02-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "9", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "45", "bibliographic_titles": [{"bibliographic_title": "Journal of wellness and health care"}, {"bibliographic_title": "Journal of wellness and health care", "bibliographic_titleLang": "en"}]}]}, "item_7_creator_34": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小ノ澤, 真一"}], "nameIdentifiers": [{"nameIdentifier": "103589", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "染矢, 富士子"}], "nameIdentifiers": [{"nameIdentifier": "495", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60187903", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60187903"}, {"nameIdentifier": "60187903", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=60187903"}, {"nameIdentifier": "60187903", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060187903"}]}, {"creatorNames": [{"creatorName": "塗谷, 栄治"}], "nameIdentifiers": [{"nameIdentifier": "31426", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70180693", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70180693"}]}]}, "item_7_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Background: Lung compliance is a parameter of lung expansion. In patients on\nventilator management, it affects ventilatory status and mortality. There are few studies\non permanent ventilator dependence (PVD), a condition defined as when a patient has\nbeen on ventilator management for more than three months. We aimed to clarify the\nlongitudinal factors affecting lung compliance during the chronic period in PVD subjects.\nMethods: A follow-up study was performed on 24 PVD subjects who had been on\nventilator management for approximately 6 years. Static (Cst) and dynamic (Cdyn) lung\ncompliance and alveolar-arterial PO2 difference (P(A-a)O2) were assessed twice between\n2019 and 2020, and the before and after results were compared for each assessment. We\nexamined the correlation of changes in Cst and Cdyn over time with BMI, age, duration of\nventilation dependence, and the incidence of pneumonia. The subjects were divided into\ntwo groups according to the presence of atelectasis, and changes in Cst, Cdyn, and P(A-a)\nO2 were compared between the two groups.\nResults: There were no significant changes in lung compliance between the two\nmeasurements in the follow-up. However, at the individual level, a decrease in BMI\ninhibited the decrease in Cst. There was no relationship between differences in Cst or\nCdyn and P(A-a)O2, age, ventilator management days, or the incidence of pneumonia.\nDifferences in P(A-a)O2 were not observed between the two groups divided according to\nthe presence of atelectasis.\nConclusions: Increased BMI affected lung compliance in PVD subjects during the chronic\nperiod. Regarding atelectasis, its relationship with differences in Cst and Cdyn was not\nclear, and impaired lung compliance was considered to resolve after several years of PVD.", "subitem_description_type": "Abstract"}]}, "item_7_heading_33": {"attribute_name": "見出し", "attribute_value_mlt": [{"subitem_heading_banner_headline": "原著", "subitem_heading_language": "ja"}, {"subitem_heading_banner_headline": "Original Article", "subitem_heading_language": "en"}]}, "item_7_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00065209", "subitem_identifier_reg_type": "JaLC"}]}, "item_7_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wellness and Health Care Society "}]}, "item_7_publisher_19": {"attribute_name": "出版者(別名)", "attribute_value_mlt": [{"subitem_publisher": "ウェルネス・ヘルスケア学会 "}]}, "item_7_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "ウェルネス・ヘルスケア学会"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2434-1509", "subitem_source_identifier_type": "ISSN"}]}, "item_7_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Onozawa, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "103586", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Someya, Fujiko"}], "nameIdentifiers": [{"nameIdentifier": "84799", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60187903", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60187903"}]}, {"creatorNames": [{"creatorName": "Nuriya, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "103588", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70180693", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70180693"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-02-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "2434-1509-45-2-1-9.pdf", "filesize": [{"value": "974.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 974400.0, "url": {"label": "2434-1509-45-2-1-9.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/58947/files/2434-1509-45-2-1-9.pdf"}, "version_id": "c19454eb-0f08-41ea-b345-00e7d243672c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Permanent ventilation dependence", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mechanical ventilation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Lung compliance", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Body mass index", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Atelectasis", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Factors associated with decreased lung compliance in subjects with permanent ventilation dependence:A follow-up study", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Factors associated with decreased lung compliance in subjects with permanent ventilation dependence:A follow-up study"}]}, "item_type_id": "7", "owner": "3", "path": ["4047"], "permalink_uri": "https://doi.org/10.24517/00065209", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-02-01"}, "publish_date": "2022-02-01", "publish_status": "0", "recid": "58947", "relation": {}, "relation_version_is_last": true, "title": ["Factors associated with decreased lung compliance in subjects with permanent ventilation dependence:A follow-up study"], "weko_shared_id": 3}
Factors associated with decreased lung compliance in subjects with permanent ventilation dependence:A follow-up study
https://doi.org/10.24517/00065209
https://doi.org/10.24517/00065209b2d8e2ee-abd6-4b66-89dc-5de7d6d1134c
名前 / ファイル | ライセンス | アクション |
---|---|---|
2434-1509-45-2-1-9.pdf (974.4 kB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-01 | |||||
タイトル | ||||||
タイトル | Factors associated with decreased lung compliance in subjects with permanent ventilation dependence:A follow-up study | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Permanent ventilation dependence | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Mechanical ventilation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Lung compliance | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Body mass index | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Atelectasis | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.24517/00065209 | |||||
ID登録タイプ | JaLC | |||||
その他のタイトル | ||||||
その他のタイトル | 人工呼吸依存患者における肺コンプライアンス低下の要因について:追跡研究 | |||||
著者 |
Onozawa, Shinichi
× Onozawa, Shinichi× Someya, Fujiko× Nuriya, Eiji |
|||||
著者別表示 |
小ノ澤, 真一
× 小ノ澤, 真一× 染矢, 富士子× 塗谷, 栄治 |
|||||
書誌情報 |
Journal of wellness and health care en : Journal of wellness and health care 巻 45, 号 2, p. 1-9, 発行日 2022-02-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2434-1509 | |||||
出版者 | ||||||
出版者 | Wellness and Health Care Society | |||||
出版者(別名) | ||||||
出版者 | ウェルネス・ヘルスケア学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: Lung compliance is a parameter of lung expansion. In patients on ventilator management, it affects ventilatory status and mortality. There are few studies on permanent ventilator dependence (PVD), a condition defined as when a patient has been on ventilator management for more than three months. We aimed to clarify the longitudinal factors affecting lung compliance during the chronic period in PVD subjects. Methods: A follow-up study was performed on 24 PVD subjects who had been on ventilator management for approximately 6 years. Static (Cst) and dynamic (Cdyn) lung compliance and alveolar-arterial PO2 difference (P(A-a)O2) were assessed twice between 2019 and 2020, and the before and after results were compared for each assessment. We examined the correlation of changes in Cst and Cdyn over time with BMI, age, duration of ventilation dependence, and the incidence of pneumonia. The subjects were divided into two groups according to the presence of atelectasis, and changes in Cst, Cdyn, and P(A-a) O2 were compared between the two groups. Results: There were no significant changes in lung compliance between the two measurements in the follow-up. However, at the individual level, a decrease in BMI inhibited the decrease in Cst. There was no relationship between differences in Cst or Cdyn and P(A-a)O2, age, ventilator management days, or the incidence of pneumonia. Differences in P(A-a)O2 were not observed between the two groups divided according to the presence of atelectasis. Conclusions: Increased BMI affected lung compliance in PVD subjects during the chronic period. Regarding atelectasis, its relationship with differences in Cst and Cdyn was not clear, and impaired lung compliance was considered to resolve after several years of PVD. |
|||||
権利 | ||||||
権利情報 | ウェルネス・ヘルスケア学会 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
見出し | ||||||
大見出し | 原著 | |||||
言語 | ja | |||||
見出し | ||||||
大見出し | Original Article | |||||
言語 | en |