{"_buckets": {"deposit": "2011ed14-9b2e-4753-a2ae-7d33c3fac92a"}, "_deposit": {"created_by": 3, "id": "644", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "644"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00000644", "sets": ["16"]}, "author_link": ["168", "3471", "3470"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "75", "bibliographicPageStart": "71", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "Sport Sciences for Health"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of this study was to compare oxygenation kinetics measured by slightly different placements of a near-infrared spectroscopy (NIRS) probe during sustained isometric gripping. Oxygenation kinetics of sixteen young adult males was measured with two NIRS probes attached to the flexor carpiradialis muscle during gripping for 3 min. One probe (channel 1) was attached at one-third the length of a line from the medial epicondyle of the humerus to the styloid process of radius. Another probe (channel 2) was attached at the palmaris longus. Although the cross-correlation coefficients for the two probe placements regarding oxygenated hemoglobin (oxy-Hb/Mb), deoxygenated hemoglobin (deoxy-Hb/Mb) and tissue oxygenation saturation (StO2) were low (rxy, 0.119-0.405), Pearson\u0027s correlation coefficients for the times to reach almost steady state for these parameters were very high (oxy-Hb/Mb, r=0.878; deoxy-Hb/Mb, r=0.769; StO2, r=0.843; p\u003c0.05). The difference of oxygenation kinetics between the probe placements may reflect the difference of fiber recruitment characteristics in the flexion muscle group. In conclusion, to obtain a stable measurement, it is important that the NIRS probe is placed at the same anatomical point. © Springer-Verlag Italia 2007.", "subitem_description_type": "Abstract"}]}, "item_4_description_5": {"attribute_name": "提供者所属", "attribute_value_mlt": [{"subitem_description": "金沢大学人間社会研究域人間科学系", "subitem_description_type": "Other"}, {"subitem_description": "福井大学医学部", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer Verlag (Germany)"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s11332-007-0042-2", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1824-7490", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Demura, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "168", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=20155485"}, {"nameIdentifier": "20155485", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000020155485"}]}, {"creatorNames": [{"creatorName": "Yamaji, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "3470", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Takayoshi"}], "nameIdentifiers": [{"nameIdentifier": "3471", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-02"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ED-PR-DEMURA-YAMAJI-71.pdf", "filesize": [{"value": "266.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 266800.0, "url": {"label": "ED-PR-DEMURA-YAMAJI-71.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/644/files/ED-PR-DEMURA-YAMAJI-71.pdf"}, "version_id": "f8326111-3d9b-44e4-b505-da4eaaec11c6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Cross-correlation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Deoxygenated hemoglobin", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Oxygenated hemoglobin", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping"}]}, "item_type_id": "4", "owner": "3", "path": ["16"], "permalink_uri": "http://hdl.handle.net/2297/11559", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-02"}, "publish_date": "2017-10-02", "publish_status": "0", "recid": "644", "relation": {}, "relation_version_is_last": true, "title": ["Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping"], "weko_shared_id": -1}
Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping
http://hdl.handle.net/2297/11559
http://hdl.handle.net/2297/11559f24b1463-a711-4488-a658-b27c70af2de8
名前 / ファイル | ライセンス | アクション |
---|---|---|
ED-PR-DEMURA-YAMAJI-71.pdf (266.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-02 | |||||
タイトル | ||||||
タイトル | Comparison of oxygenation kinetics measured by different placements of the NIRS probe during sustained isometric gripping | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Demura, Shinichi
× Demura, Shinichi× Yamaji, Shunsuke× Yamada, Takayoshi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学人間社会研究域人間科学系 | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 福井大学医学部 | |||||
書誌情報 |
Sport Sciences for Health 巻 2, 号 2, p. 71-75, 発行日 2007-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1824-7490 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s11332-007-0042-2 | |||||
出版者 | ||||||
出版者 | Springer Verlag (Germany) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to compare oxygenation kinetics measured by slightly different placements of a near-infrared spectroscopy (NIRS) probe during sustained isometric gripping. Oxygenation kinetics of sixteen young adult males was measured with two NIRS probes attached to the flexor carpiradialis muscle during gripping for 3 min. One probe (channel 1) was attached at one-third the length of a line from the medial epicondyle of the humerus to the styloid process of radius. Another probe (channel 2) was attached at the palmaris longus. Although the cross-correlation coefficients for the two probe placements regarding oxygenated hemoglobin (oxy-Hb/Mb), deoxygenated hemoglobin (deoxy-Hb/Mb) and tissue oxygenation saturation (StO2) were low (rxy, 0.119-0.405), Pearson's correlation coefficients for the times to reach almost steady state for these parameters were very high (oxy-Hb/Mb, r=0.878; deoxy-Hb/Mb, r=0.769; StO2, r=0.843; p<0.05). The difference of oxygenation kinetics between the probe placements may reflect the difference of fiber recruitment characteristics in the flexion muscle group. In conclusion, to obtain a stable measurement, it is important that the NIRS probe is placed at the same anatomical point. © Springer-Verlag Italia 2007. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |