WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "a3de813b-5dd4-48de-a834-3ada4313ba66"}, "_deposit": {"created_by": 3, "id": "8402", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "8402"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00008402", "sets": ["936"]}, "author_link": ["11775", "10974"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-12-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "1278", "bibliographicPageStart": "1272", "bibliographicVolumeNumber": "45", "bibliographic_titles": [{"bibliographic_title": "Behavior Research Methods"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Heart rate (HR) and normalized pulse volume (NPV) are physiological indices that have been used in a diversity of psychological studies. However, measuring these indices often requires laborious processes. We therefore developed a new smartphone program, named iPhysioMeter, that makes it possible to measure beat-by-beat HR and ln NPV using only a smartphone. We examined its accuracy against conventional laboratory measures. Mental stress tasks were used to alter HR and ln NPV in 12 participants. Bland–Altman analyses revealed negligible proportional bias for HR and ln NPV or for their change values, expressed as ΔHR and Δln NPV. However, a relatively large fixed bias did emerge for ln NPV, as well as a small one for Δln NPV, although both were within the limits of agreement. These findings suggest that iPhysioMeter can yield valid measures of the absolute level of HR and of relative changes in ln NPV.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Springer-Verlag"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.3758/s13428-012-0312-z", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12568600", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1554-3528", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsumura, Kenta"}], "nameIdentifiers": [{"nameIdentifier": "11775", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "10974", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070444205"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-MATSUMURA-K-1272.pdf", "filesize": [{"value": "655.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 655600.0, "url": {"label": "TE-PR-MATSUMURA-K-1272.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/8402/files/TE-PR-MATSUMURA-K-1272.pdf"}, "version_id": "55570c90-7356-4090-960d-eda5490bc827"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Electrocardiograph", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Finger photo-plethysmograph", "subitem_subject_scheme": "Other"}, {"subitem_subject": "iPhone", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mobile health", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/33684", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "8402", "relation": {}, "relation_version_is_last": true, "title": ["iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone"], "weko_shared_id": -1}
iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone
http://hdl.handle.net/2297/33684
http://hdl.handle.net/2297/33684810ea29d-20fd-48f8-aa37-1a77e008b01e
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-MATSUMURA-K-1272.pdf (655.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Matsumura, Kenta
× Matsumura, Kenta× Yamakoshi, Takehiro |
|||||
書誌情報 |
Behavior Research Methods 巻 45, 号 4, p. 1272-1278, 発行日 2013-12-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1554-3528 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12568600 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3758/s13428-012-0312-z | |||||
出版者 | ||||||
出版者 | Springer-Verlag | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Heart rate (HR) and normalized pulse volume (NPV) are physiological indices that have been used in a diversity of psychological studies. However, measuring these indices often requires laborious processes. We therefore developed a new smartphone program, named iPhysioMeter, that makes it possible to measure beat-by-beat HR and ln NPV using only a smartphone. We examined its accuracy against conventional laboratory measures. Mental stress tasks were used to alter HR and ln NPV in 12 participants. Bland–Altman analyses revealed negligible proportional bias for HR and ln NPV or for their change values, expressed as ΔHR and Δln NPV. However, a relatively large fixed bias did emerge for ln NPV, as well as a small one for Δln NPV, although both were within the limits of agreement. These findings suggest that iPhysioMeter can yield valid measures of the absolute level of HR and of relative changes in ln NPV. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |