{"_buckets": {"deposit": "35d98808-01ac-42c1-95a9-91c00a4313cd"}, "_deposit": {"created_by": 3, "id": "8605", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "8605"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00008605", "sets": ["936"]}, "author_link": ["12180", "12181", "10974", "12182", "42", "12183", "12184"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-03-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "375", "bibliographicPageStart": "359", "bibliographicVolumeNumber": "34", "bibliographic_titles": [{"bibliographic_title": "Physiological Measurement"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress. © 2013 Institute of Physics and Engineering in Medicine.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Physics"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/0967-3334/34/3/359", "subitem_relation_type_select": "DOI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10890861", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0967-3334", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Lee, Jihyoung"}], "nameIdentifiers": [{"nameIdentifier": "12180", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumura, Kenta"}], "nameIdentifiers": [{"nameIdentifier": "12181", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "10974", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70444205"}, {"nameIdentifier": "70444205", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070444205"}]}, {"creatorNames": [{"creatorName": "Rolfe, Peter"}], "nameIdentifiers": [{"nameIdentifier": "12182", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, Naoto"}], "nameIdentifiers": [{"nameIdentifier": "12183", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kim, Kyungho"}], "nameIdentifiers": [{"nameIdentifier": "12184", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakoshi, Ken-ichi"}], "nameIdentifiers": [{"nameIdentifier": "42", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40014310"}, {"nameIdentifier": "40014310", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040014310"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MATSUMURA-K-359.pdf", "filesize": [{"value": "585.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 585800.0, "url": {"label": "ME-PR-MATSUMURA-K-359.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/8605/files/ME-PR-MATSUMURA-K-359.pdf"}, "version_id": "20d06707-fefb-4a38-8d8d-88791e7675da"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "cold pressor test", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ear-canal", "subitem_subject_scheme": "Other"}, {"subitem_subject": "normalized pulse volume (NPV)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "photoplethysmography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "stress monitoring", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/34137", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "8605", "relation": {}, "relation_version_is_last": true, "title": ["Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring"], "weko_shared_id": -1}
Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring
http://hdl.handle.net/2297/34137
http://hdl.handle.net/2297/34137a66632e2-e2be-43b5-b347-632ee0c4269d
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MATSUMURA-K-359.pdf (585.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Lee, Jihyoung
× Lee, Jihyoung× Matsumura, Kenta× Yamakoshi, Takehiro× Rolfe, Peter× Tanaka, Naoto× Kim, Kyungho× Yamakoshi, Ken-ichi |
|||||
書誌情報 |
Physiological Measurement 巻 34, 号 3, p. 359-375, 発行日 2013-03-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0967-3334 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10890861 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/0967-3334/34/3/359 | |||||
出版者 | ||||||
出版者 | Institute of Physics | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress. © 2013 Institute of Physics and Engineering in Medicine. | |||||