{"_buckets": {"deposit": "c209e227-a554-496c-ad8a-820f24a514ba"}, "_deposit": {"created_by": 3, "id": "8751", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "8751"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00008751", "sets": ["936"]}, "author_link": ["601", "7684"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "1013", "bibliographicPageStart": "1009", "bibliographicVolumeNumber": "47", "bibliographic_titles": [{"bibliographic_title": "Radiation Measurements"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We report a novel two- and three-dimensional (2-D, 3-D) imaging detector based on the radiophotoluminescence (RPL) phenomenon in silver-activated phosphate glass (PG:Ag) and evaluate its dosimetric characteristics. A compact disk-type PG:Ag detector with a diameter of 80 mm was rotated at a rate of 400 rpm to read out the accumulated dose information and then remove the images for reuse. After X-ray exposure, three RPL dosimeter processes, i.e.; preheating, reading, and erasing, were carried out with only a UV laser at 375 nm by adjusting the stepwise output levels. The 3-D images and dose distributions were rapidly reconstructed with a high spatial resolution of 1 μm and a sensitivity of 1 mGy. © 2012 Elsevier Ltd. All rights reserved.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.radmeas.2012.09.003", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.elsevier.com/locate/issn/13504487", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11020151", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1350-4487", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kurobori, Toshio"}], "nameIdentifiers": [{"nameIdentifier": "7684", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90153428", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090153428"}]}, {"creatorNames": [{"creatorName": "Nakamura, Shoichi"}], "nameIdentifiers": [{"nameIdentifier": "601", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70175503", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070175503"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ED-PR-KUROBORI-T-1009.pdf", "filesize": [{"value": "472.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 472000.0, "url": {"label": "ED-PR-KUROBORI-T-1009.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/8751/files/ED-PR-KUROBORI-T-1009.pdf"}, "version_id": "64ff0eda-e8a1-4a38-9eaa-b89bf33eac8e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Ag-doped phosphate glass", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Glass dosimeter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiophotoluminescence (RPL)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Silver defect clusters", "subitem_subject_scheme": "Other"}, {"subitem_subject": "X-ray imaging", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/32826", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "8751", "relation": {}, "relation_version_is_last": true, "title": ["A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass"], "weko_shared_id": -1}
A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass
http://hdl.handle.net/2297/32826
http://hdl.handle.net/2297/3282698ecf886-8632-4b4d-81f5-e586f265b3ab
名前 / ファイル | ライセンス | アクション |
---|---|---|
ED-PR-KUROBORI-T-1009.pdf (472.0 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | A novel disk-type X-ray area imaging detector using radiophotoluminescence in silver-activated phosphate glass | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kurobori, Toshio
× Kurobori, Toshio× Nakamura, Shoichi |
|||||
書誌情報 |
Radiation Measurements 巻 47, 号 10, p. 1009-1013, 発行日 2012-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11020151 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radmeas.2012.09.003 | |||||
出版者 | ||||||
出版者 | Elsevier | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We report a novel two- and three-dimensional (2-D, 3-D) imaging detector based on the radiophotoluminescence (RPL) phenomenon in silver-activated phosphate glass (PG:Ag) and evaluate its dosimetric characteristics. A compact disk-type PG:Ag detector with a diameter of 80 mm was rotated at a rate of 400 rpm to read out the accumulated dose information and then remove the images for reuse. After X-ray exposure, three RPL dosimeter processes, i.e.; preheating, reading, and erasing, were carried out with only a UV laser at 375 nm by adjusting the stepwise output levels. The 3-D images and dose distributions were rapidly reconstructed with a high spatial resolution of 1 μm and a sensitivity of 1 mGy. © 2012 Elsevier Ltd. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/13504487 |