{"_buckets": {"deposit": "9ff8edb8-f748-4357-a1bf-8aa709646ae2"}, "_deposit": {"created_by": 3, "id": "9003", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9003"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009003", "sets": ["936"]}, "author_link": ["11069", "189", "12792"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "390", "bibliographicPageStart": "386", "bibliographicVolumeNumber": "21", "bibliographic_titles": [{"bibliographic_title": "日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Miniaturization of electronic devices has making progress, resulting in smaller current flowing in extremely high-density LSI (large scale integration) or PCB (printed circuit board). However, measurements of such low local current have still been confronted with many difficulties because of the limitation on size of relatively large and cumbersome typical current sensors, lead to detecting general signals of a wide area. In this research, we propose the novel micron size and high sensitivity needle-type GMR probe in applications of non-contact measuring low currents coming from area narrower than 10-6 m2 with small signal crosstalk such as PCB current measurement and low bio magnetic signal detection. Low current of hundreds μA in high-density PCB tracks of 4×10-4 m pitch was measured with the signal crosstalk less than 10% and 5×10-6 A of nerve signal model was possible to be detected by micron size GMR probe.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本AEM学会 = The Japan Society of Applied Electromagnetics and Mechanics"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.14243/jsaem.21.386", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jsaem/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsaem.gr.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2013 The Japan Society of Applied Electromagnetics and Mechanics 日本AEM学会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_4_text_2": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_text_value": "[特集] Asia-Pacific Symposium on Applied Electromagnetics and Mechanics"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hoang, H."}], "nameIdentifiers": [{"nameIdentifier": "12792", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kakikawa, Makiko"}], "nameIdentifiers": [{"nameIdentifier": "189", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010359713"}]}, {"creatorNames": [{"creatorName": "Yamada, Sotoshi"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-386.pdf", "filesize": [{"value": "2.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2700000.0, "url": {"label": "TE-PR-YAMADA-S-386.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9003/files/TE-PR-YAMADA-S-386.pdf"}, "version_id": "2b84baa7-89fa-45fb-9dc5-7f0054f9b42f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "giant magnetoresistive sensor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "GMR", "subitem_subject_scheme": "Other"}, {"subitem_subject": "low current", "subitem_subject_scheme": "Other"}, {"subitem_subject": "high spatial resolution", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PCB track", "subitem_subject_scheme": "Other"}, {"subitem_subject": "nerve signal model", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/36994", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9003", "relation": {}, "relation_version_is_last": true, "title": ["High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe"], "weko_shared_id": -1}
High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe
http://hdl.handle.net/2297/36994
http://hdl.handle.net/2297/3699497eede3f-83b9-4e3a-8a57-570640345cc8
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-386.pdf (2.7 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | High Spatial Resolution Non-contact Measurement of Low Current Signal by Needle-Type GMR Probe | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他のタイトル | ||||||
[特集] Asia-Pacific Symposium on Applied Electromagnetics and Mechanics | ||||||
著者 |
Hoang, H.
× Hoang, H.× Kakikawa, Makiko× Yamada, Sotoshi |
|||||
書誌情報 |
日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics 巻 21, 号 3, p. 386-390, 発行日 2013-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0919-4452 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10457520 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.14243/jsaem.21.386 | |||||
出版者 | ||||||
出版者 | 日本AEM学会 = The Japan Society of Applied Electromagnetics and Mechanics | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Miniaturization of electronic devices has making progress, resulting in smaller current flowing in extremely high-density LSI (large scale integration) or PCB (printed circuit board). However, measurements of such low local current have still been confronted with many difficulties because of the limitation on size of relatively large and cumbersome typical current sensors, lead to detecting general signals of a wide area. In this research, we propose the novel micron size and high sensitivity needle-type GMR probe in applications of non-contact measuring low currents coming from area narrower than 10-6 m2 with small signal crosstalk such as PCB current measurement and low bio magnetic signal detection. Low current of hundreds μA in high-density PCB tracks of 4×10-4 m pitch was measured with the signal crosstalk less than 10% and 5×10-6 A of nerve signal model was possible to be detected by micron size GMR probe. | |||||
権利 | ||||||
権利情報 | Copyright © 2013 The Japan Society of Applied Electromagnetics and Mechanics 日本AEM学会 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jsaem/-char/ja/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsaem.gr.jp/ |