WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "855f7885-b892-4520-9031-bba75a7c96b8"}, "_deposit": {"created_by": 3, "id": "9072", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9072"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009072", "sets": ["936"]}, "author_link": ["12412", "10422", "12907"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-10-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "1452", "bibliographicPageStart": "1448", "bibliographicVolumeNumber": "61", "bibliographic_titles": [{"bibliographic_title": "精密工学会誌 = Journal of the Japan Society of Precision Engineering"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Temperature of interface between a cutting tool and a workpiece is measured using two-color pyrometer with a fused fiber coupler. A conical tool is used as the cutting tool which is made of translucent alumina sintered under HIP, and 0.55% carbon steel is used as a workpiece. The infrared rays radiated from the interface and transmitted through the conical tool are accepted by a fused fiber coupler and led to two infrared detectors of different spectral sensitivity. Temperature is obtained by calculating the ratio of the output voltage from these two detectors. The results obtained are as follows. The temperature increases very rapidly and reaches 1000°C at about 40 μs after the beginning of cutting. The rate of increase of temperature is very great : about 108 °C/s at the cutting speed of 1 500 m/min. The temperature increases with the increase of cutting speed, but at a speed faster than 1000 m/min its influence is small. The temperature shows a tendency to saturate about 1300-1400°C as the cutting speed increases.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "精密工学会 = The Japan Society for Precision Engineering"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2493/jjspe.61.1448", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jspe.or.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jjspe", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110001371741", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2007 The Japan Society for Precision Engineering 精密工学会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN1003250X", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0912-0289", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "上田, 隆司"}], "nameIdentifiers": [{"nameIdentifier": "10422", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60115996", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60115996"}, {"nameIdentifier": "60115996", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060115996"}]}, {"creatorNames": [{"creatorName": "佐藤, 昌彦"}], "nameIdentifiers": [{"nameIdentifier": "12907", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "杉田, 忠彰"}], "nameIdentifiers": [{"nameIdentifier": "12412", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70019769", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70019769"}, {"nameIdentifier": "70019769", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000070019769"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-UEDA-T-1448.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "TE-PR-UEDA-T-1448.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9072/files/TE-PR-UEDA-T-1448.pdf"}, "version_id": "e4feee4a-fcbf-4443-8fdc-3a83b6ae79f7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "tool-workpiece interface temperature", "subitem_subject_scheme": "Other"}, {"subitem_subject": "temperature measurement,", "subitem_subject_scheme": "Other"}, {"subitem_subject": "two-color pyrometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "fused fiber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "coupler", "subitem_subject_scheme": "Other"}, {"subitem_subject": "optical fiber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "infrared radiation pyrometer", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "工具-加工物接触面温度の測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "工具-加工物接触面温度の測定"}, {"subitem_title": "Measurement of Tool-Workpiece Interface Temperature by Two-Color Pyrometer", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/38879", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9072", "relation": {}, "relation_version_is_last": true, "title": ["工具-加工物接触面温度の測定"], "weko_shared_id": -1}
工具-加工物接触面温度の測定
http://hdl.handle.net/2297/38879
http://hdl.handle.net/2297/3887942ba1961-1ab4-4f50-a663-2e568ff91702
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-UEDA-T-1448.pdf (1.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 工具-加工物接触面温度の測定 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Measurement of Tool-Workpiece Interface Temperature by Two-Color Pyrometer | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
上田, 隆司
× 上田, 隆司× 佐藤, 昌彦× 杉田, 忠彰 |
|||||
書誌情報 |
精密工学会誌 = Journal of the Japan Society of Precision Engineering 巻 61, 号 10, p. 1448-1452, 発行日 1995-10-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0912-0289 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN1003250X | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2493/jjspe.61.1448 | |||||
出版者 | ||||||
出版者 | 精密工学会 = The Japan Society for Precision Engineering | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Temperature of interface between a cutting tool and a workpiece is measured using two-color pyrometer with a fused fiber coupler. A conical tool is used as the cutting tool which is made of translucent alumina sintered under HIP, and 0.55% carbon steel is used as a workpiece. The infrared rays radiated from the interface and transmitted through the conical tool are accepted by a fused fiber coupler and led to two infrared detectors of different spectral sensitivity. Temperature is obtained by calculating the ratio of the output voltage from these two detectors. The results obtained are as follows. The temperature increases very rapidly and reaches 1000°C at about 40 μs after the beginning of cutting. The rate of increase of temperature is very great : about 108 °C/s at the cutting speed of 1 500 m/min. The temperature increases with the increase of cutting speed, but at a speed faster than 1000 m/min its influence is small. The temperature shows a tendency to saturate about 1300-1400°C as the cutting speed increases. | |||||
権利 | ||||||
権利情報 | Copyright © 2007 The Japan Society for Precision Engineering 精密工学会 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jspe.or.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jjspe | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110001371741 |