{"_buckets": {"deposit": "d534b1b2-b902-4c34-8901-294243ad013d"}, "_deposit": {"created_by": 3, "id": "9101", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9101"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009101", "sets": ["936"]}, "author_link": ["12949", "10422", "12948"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "896", "bibliographicPageStart": "892", "bibliographicVolumeNumber": "64", "bibliographic_titles": [{"bibliographic_title": "精密工学会誌 = Journal of the Japan Society of Precision Engineering"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Tool face temperature of single crystal diamond in high precision orthogonal cutting of aluminum and copper is measured using two-color pyrometer with an optical fiber. The infrared rays radiated from the chip-tool interface and transmitted through the diamond tool are accepted by an optical fiber and led to two-color detectors of different spectral sensitivity. Temperature distribution on the tool face is analyzed by employing finite element method and calculated results are applied to the estimation of the maximum temperature on the tool face. The results obtained are as follows; (1) The technique developed is suitable for measuring the tool face temperature in single crystal diamond cutting. (2) Output wave of temperature was clearly recorded. The tool face temperature measured is approximately 190°C for Al and approximately 220°C for Cu when cutting speed was about 620m/min. (3) The temperature increases with the increase of cutting speed. (4) The temperature on the tool face measured is in good agreement with that calculated.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "精密工学会 = The Japan Society for Precision Engineering"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2493/jjspe.64.892", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jspe.or.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jjspe", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110001367958/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 2007 The Japan Society for Precision Engineering 精密工学会"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN1003250X", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0912-0289", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "佐藤, 昌彦"}], "nameIdentifiers": [{"nameIdentifier": "12948", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上田, 隆司"}], "nameIdentifiers": [{"nameIdentifier": "10422", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "60115996", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=60115996"}, {"nameIdentifier": "60115996", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000060115996"}]}, {"creatorNames": [{"creatorName": "西田, 昌弘"}], "nameIdentifiers": [{"nameIdentifier": "12949", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-UEDA-T-892.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "TE-PR-UEDA-T-892.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9101/files/TE-PR-UEDA-T-892.pdf"}, "version_id": "b5a313f2-1761-4a26-9ff3-6019d4875b6a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "diamond cutting", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tool face temperature", "subitem_subject_scheme": "Other"}, {"subitem_subject": "temperature measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "optical fiber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "two color pyrometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "finite element method", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "単結晶ダイヤモンド二次元切削における工具すくい面温度の測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "単結晶ダイヤモンド二次元切削における工具すくい面温度の測定"}, {"subitem_title": "Measurement of Tool Face Temperature in Orthogonal Diamond Cutting", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/38805", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9101", "relation": {}, "relation_version_is_last": true, "title": ["単結晶ダイヤモンド二次元切削における工具すくい面温度の測定"], "weko_shared_id": -1}
単結晶ダイヤモンド二次元切削における工具すくい面温度の測定
http://hdl.handle.net/2297/38805
http://hdl.handle.net/2297/38805e0c6fa5e-9842-4449-b41f-d00f6815b793
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-UEDA-T-892.pdf (1.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 単結晶ダイヤモンド二次元切削における工具すくい面温度の測定 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Measurement of Tool Face Temperature in Orthogonal Diamond Cutting | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
佐藤, 昌彦
× 佐藤, 昌彦× 上田, 隆司× 西田, 昌弘 |
|||||
書誌情報 |
精密工学会誌 = Journal of the Japan Society of Precision Engineering 巻 64, 号 6, p. 892-896, 発行日 1998-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0912-0289 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN1003250X | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2493/jjspe.64.892 | |||||
出版者 | ||||||
出版者 | 精密工学会 = The Japan Society for Precision Engineering | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Tool face temperature of single crystal diamond in high precision orthogonal cutting of aluminum and copper is measured using two-color pyrometer with an optical fiber. The infrared rays radiated from the chip-tool interface and transmitted through the diamond tool are accepted by an optical fiber and led to two-color detectors of different spectral sensitivity. Temperature distribution on the tool face is analyzed by employing finite element method and calculated results are applied to the estimation of the maximum temperature on the tool face. The results obtained are as follows; (1) The technique developed is suitable for measuring the tool face temperature in single crystal diamond cutting. (2) Output wave of temperature was clearly recorded. The tool face temperature measured is approximately 190°C for Al and approximately 220°C for Cu when cutting speed was about 620m/min. (3) The temperature increases with the increase of cutting speed. (4) The temperature on the tool face measured is in good agreement with that calculated. | |||||
権利 | ||||||
権利情報 | Copyright © 2007 The Japan Society for Precision Engineering 精密工学会 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||