WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "1edc2680-ab22-4f23-9889-a6435f322458"}, "_deposit": {"created_by": 3, "id": "9167", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9167"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009167", "sets": ["936"]}, "author_link": ["13075", "11069", "13076", "189", "11068"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-09-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "460", "bibliographicPageStart": "457", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Utilization of magnetic nanoparticles in biomedicine has seen an unprecedented growth in recent years. The ability to accurately estimate magnetic nanoparticles inside small areas of the body provides an advantage in hyperthermia therapy, a form of cancer treatment. This paper concentrates on a novel giant magnetoresistance (GMR) needle-type sensor to detect and estimate low concentration magnetic fluid inside minute agar cavities injected with magnetic fluid. Theoretical analysis, experimental results and information on the fabricated GMR needle-type sensor are reported. The experimental results show a favorable agreement to the analytical analysis, supporting the potential use of the GMR needle-type sensor in hyperthermia therapy", "subitem_description_type": "Abstract"}]}, "item_4_description_22": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "\u003cSpecial Issue\u003e Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08)", "subitem_description_type": "Other"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本AEM学会 = The Japan Society of Applied Electromagnetics"}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.jsaem.gr.jp/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jsaem", "subitem_relation_type_select": "URI"}}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Gooneratne, C. P."}], "nameIdentifiers": [{"nameIdentifier": "13075", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Sotoshi"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}, {"creatorNames": [{"creatorName": "Iwahara, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "11068", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80020212", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080020212"}]}, {"creatorNames": [{"creatorName": "Kakikawa, Makiko"}], "nameIdentifiers": [{"nameIdentifier": "189", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=10359713"}, {"nameIdentifier": "10359713", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000010359713"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Y."}], "nameIdentifiers": [{"nameIdentifier": "13076", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-457.pdf", "filesize": [{"value": "321.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 321400.0, "url": {"label": "TE-PR-YAMADA-S-457.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9167/files/TE-PR-YAMADA-S-457.pdf"}, "version_id": "1a55458f-ae90-4413-a628-9193b112511b"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "giant magnetoresistance", "subitem_subject_scheme": "Other"}, {"subitem_subject": "hyperthermia therapy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic nanoparticles", "subitem_subject_scheme": "Other"}, {"subitem_subject": "demagnetizing factor", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/48629", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9167", "relation": {}, "relation_version_is_last": true, "title": ["Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities"], "weko_shared_id": 3}
Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities
http://hdl.handle.net/2297/48629
http://hdl.handle.net/2297/486295041f05e-b342-4637-940f-591ae5a8ed03
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-457.pdf (321.4 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Gooneratne, C. P.
× Gooneratne, C. P.× Yamada, Sotoshi× Iwahara, Masayoshi× Kakikawa, Makiko× Matsumoto, Y. |
|||||
書誌情報 |
日本AEM学会誌 = Journal of the Japan Society of Applied Electromagnetics 巻 17, 号 3, p. 457-460, 発行日 2009-09-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0919-4452 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10457520 | |||||
出版者 | ||||||
出版者 | 日本AEM学会 = The Japan Society of Applied Electromagnetics | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Utilization of magnetic nanoparticles in biomedicine has seen an unprecedented growth in recent years. The ability to accurately estimate magnetic nanoparticles inside small areas of the body provides an advantage in hyperthermia therapy, a form of cancer treatment. This paper concentrates on a novel giant magnetoresistance (GMR) needle-type sensor to detect and estimate low concentration magnetic fluid inside minute agar cavities injected with magnetic fluid. Theoretical analysis, experimental results and information on the fabricated GMR needle-type sensor are reported. The experimental results show a favorable agreement to the analytical analysis, supporting the potential use of the GMR needle-type sensor in hyperthermia therapy | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | <Special Issue> Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08) | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsaem.gr.jp/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jsaem |