{"_buckets": {"deposit": "f8c6026c-0046-423b-97c0-9509c949674d"}, "_deposit": {"created_by": 3, "id": "9285", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9285"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009285", "sets": ["936"]}, "author_link": ["327", "13307"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1987-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "347", "bibliographicPageStart": "337", "bibliographicVolumeNumber": "42", "bibliographic_titles": [{"bibliographic_title": "Journal of Agricultural Meteorology = 農業気象"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "埋設管型熱交換器を用いる方法は, 堆肥そうからの熱抽出において典型的で簡単な方法であるが, 混合素材の切返しを行う際に埋設管の取り外し, 再配管などの煩雑な作業を必要とする。このような煩雑な作業を簡単にするためにマルチ・ヒートパイプ熱交換器を用いたユニークな熱抽出方法を提示し, 熱抽出過程における堆肥そう内温度及び熱交換器出口における熱媒体の温度の解析解を導いた。これらの解は埋設管型熱交換器に対する解と数学的に同一であった。そして, 解析解に基づき, マルチ・ヒートパイプ熱交換器の熱抽出能力を計算した。A buried-tube-type heat exchanger is typical and simple for extracting heat from a compost bed except the requirement of some tedious works such as removing and retubing the tubes in remixing the compost materials. In order to simplify the above tedious works, a unique heat extraction method by a multi-heat-pipe heat exchanger was proposed. The analytical solutions of the temperature in the bed and the temperature of medium at the outlet of the heat exchanger were obtained. These solutions were mathematically similar to those for the buried-tube-type heat exchanger. Then, the heat extraction ability of the multi-heat-pipe heat exchanger was calculated from the solutions.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本農業気象学会 = Society of Agricultural Meteorology of Japan"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2480/agrmet.42.337", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/agrmet", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://agrmet.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © The Society of Agricultural Meteorology of Japan"}]}, "item_4_rights_24": {"attribute_name": "権利URI", "attribute_value_mlt": [{"subitem_rights": "http://www.agrmet.jp/"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12492451", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-8588", "subitem_source_identifier_type": "ISSN"}]}, "item_4_text_2": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_text_value": "マルチ・ヒートパイプ熱交換器による堆肥発酵熱抽出に関する理論的研究"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Seki, Hirakazu"}], "nameIdentifiers": [{"nameIdentifier": "327", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90115246", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000090115246"}]}, {"creatorNames": [{"creatorName": "Komori, Tomoaki"}], "nameIdentifiers": [{"nameIdentifier": "13307", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50019725", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50019725"}, {"nameIdentifier": "50019725", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050019725"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-SEKI-H-337.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "TE-PR-SEKI-H-337.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9285/files/TE-PR-SEKI-H-337.pdf"}, "version_id": "01b06fb4-f5be-4665-85f0-c82a92733d9c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A Theoretical Investigation of Heat Extraction from a Compost Bed by Using a Multi-Heat-Pipe Heat Exchanger", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A Theoretical Investigation of Heat Extraction from a Compost Bed by Using a Multi-Heat-Pipe Heat Exchanger"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/46361", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9285", "relation": {}, "relation_version_is_last": true, "title": ["A Theoretical Investigation of Heat Extraction from a Compost Bed by Using a Multi-Heat-Pipe Heat Exchanger"], "weko_shared_id": 3}
A Theoretical Investigation of Heat Extraction from a Compost Bed by Using a Multi-Heat-Pipe Heat Exchanger
http://hdl.handle.net/2297/46361
http://hdl.handle.net/2297/463610b6ce0dc-ca65-431e-b311-fb1845582bcf
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-SEKI-H-337.pdf (1.1 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | A Theoretical Investigation of Heat Extraction from a Compost Bed by Using a Multi-Heat-Pipe Heat Exchanger | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他のタイトル | ||||||
マルチ・ヒートパイプ熱交換器による堆肥発酵熱抽出に関する理論的研究 | ||||||
著者 |
Seki, Hirakazu
× Seki, Hirakazu× Komori, Tomoaki |
|||||
書誌情報 |
Journal of Agricultural Meteorology = 農業気象 巻 42, 号 4, p. 337-347, 発行日 1987-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0021-8588 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12492451 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2480/agrmet.42.337 | |||||
出版者 | ||||||
出版者 | 日本農業気象学会 = Society of Agricultural Meteorology of Japan | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 埋設管型熱交換器を用いる方法は, 堆肥そうからの熱抽出において典型的で簡単な方法であるが, 混合素材の切返しを行う際に埋設管の取り外し, 再配管などの煩雑な作業を必要とする。このような煩雑な作業を簡単にするためにマルチ・ヒートパイプ熱交換器を用いたユニークな熱抽出方法を提示し, 熱抽出過程における堆肥そう内温度及び熱交換器出口における熱媒体の温度の解析解を導いた。これらの解は埋設管型熱交換器に対する解と数学的に同一であった。そして, 解析解に基づき, マルチ・ヒートパイプ熱交換器の熱抽出能力を計算した。A buried-tube-type heat exchanger is typical and simple for extracting heat from a compost bed except the requirement of some tedious works such as removing and retubing the tubes in remixing the compost materials. In order to simplify the above tedious works, a unique heat extraction method by a multi-heat-pipe heat exchanger was proposed. The analytical solutions of the temperature in the bed and the temperature of medium at the outlet of the heat exchanger were obtained. These solutions were mathematically similar to those for the buried-tube-type heat exchanger. Then, the heat extraction ability of the multi-heat-pipe heat exchanger was calculated from the solutions. | |||||
権利 | ||||||
権利情報 | Copyright © The Society of Agricultural Meteorology of Japan | |||||
権利URI | ||||||
権利情報 | http://www.agrmet.jp/ | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/agrmet | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://agrmet.jp/ |