{"_buckets": {"deposit": "ccbea61d-616d-4ed7-a1df-bcc87f5256df"}, "_deposit": {"created_by": 3, "id": "9598", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9598"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009598", "sets": ["936"]}, "author_link": ["13919", "11069", "13921", "13920", "13918", "11068"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "3624", "bibliographicPageStart": "3622", "bibliographicVolumeNumber": "41", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Maggetics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper describes the detection of conductive microbeads (PbSn) based on eddy-current testing (ECT) technique. High-frequency magnetic field applied to the conductive microbeads enables spin-valve giant magnetoresis-tance (SV-GMR) sensor to detect the magnetic fields occurred from eddy currents flowing in the conductive microbeads. In this paper, analysis of these magnetic fields by an analytical method is discussed and compared with experimental results.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electrical and Electronics Engineers IEEE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/TMAG.2005.855172", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2005 IEEE."}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00667933", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamada, Sotoshi"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}, {"creatorNames": [{"creatorName": "Chomsuwan, K."}], "nameIdentifiers": [{"nameIdentifier": "13918", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hagino, T."}], "nameIdentifiers": [{"nameIdentifier": "13919", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tian, H."}], "nameIdentifiers": [{"nameIdentifier": "13920", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minamide, K."}], "nameIdentifiers": [{"nameIdentifier": "13921", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwahara, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "11068", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80020212", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080020212"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Conductive Microbead Array Detection by High-Frequency Eddy-Current Testing Technique With SV-GMR Sensor", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Conductive Microbead Array Detection by High-Frequency Eddy-Current Testing Technique With SV-GMR Sensor"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/48329", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9598", "relation": {}, "relation_version_is_last": true, "title": ["Conductive Microbead Array Detection by High-Frequency Eddy-Current Testing Technique With SV-GMR Sensor"], "weko_shared_id": -1}
Conductive Microbead Array Detection by High-Frequency Eddy-Current Testing Technique With SV-GMR Sensor
http://hdl.handle.net/2297/48329
http://hdl.handle.net/2297/48329ce9e1aa0-4515-4a11-9b79-98d36bfd7211
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Conductive Microbead Array Detection by High-Frequency Eddy-Current Testing Technique With SV-GMR Sensor | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yamada, Sotoshi
× Yamada, Sotoshi× Chomsuwan, K.× Hagino, T.× Tian, H.× Minamide, K.× Iwahara, Masayoshi |
|||||
書誌情報 |
IEEE Transactions on Maggetics 巻 41, 号 10, p. 3622-3624, 発行日 2005-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9464 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00667933 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TMAG.2005.855172 | |||||
出版者 | ||||||
出版者 | Institute of Electrical and Electronics Engineers IEEE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This paper describes the detection of conductive microbeads (PbSn) based on eddy-current testing (ECT) technique. High-frequency magnetic field applied to the conductive microbeads enables spin-valve giant magnetoresis-tance (SV-GMR) sensor to detect the magnetic fields occurred from eddy currents flowing in the conductive microbeads. In this paper, analysis of these magnetic fields by an analytical method is discussed and compared with experimental results. | |||||