Preconcentration of gallium(III) and indium(III) by coprecipitation with hafnium hydroxide for electrothermal: Atomic absorption spectrometry.

http://hdl.handle.net/2297/48686
http://hdl.handle.net/2297/48686
98d45ebd-c622-478c-a589-ee4355c5c32f
名前 / ファイル ライセンス アクション
ED-PR-UEDA-J-417.pdf ED-PR-UEDA-J-417.pdf (274.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Preconcentration of gallium(III) and indium(III) by coprecipitation with hafnium hydroxide for electrothermal: Atomic absorption spectrometry.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ueda, Joichi

× Ueda, Joichi

WEKO 15678

Ueda, Joichi

Search repository
Mizui, Chika

× Mizui, Chika

WEKO 15679

Mizui, Chika

Search repository
書誌情報 Analytical Sciences

巻 4, 号 4, p. 417-421, 発行日 1988-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
NCID
収録物識別子タイプ NCID
収録物識別子 AA10500785
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.2116/analsci.4.417
出版者
出版者 Japan Society for Analytical Chemistry = 日本分析化学会
内容記述
内容記述タイプ Other
内容記述 The trace amounts of gallium and indium in water were determined by graphite furnace atomic absorption spectrometry after being concentrated by the coprecipitation technique with hafnium hydroxide. Hafnium hydroxide coprecipitates quantitatively 0.2 -3 ng of gallium from 50 - 400 ml of sample solution at pH 6.0-10.5 and 0.2 -4 ng of indium from 50 - 400 ml at pH 6.0-11.0. The atomic absorbances of gallium and indium are increased about 3 times by the presence of hafnium; the reproducibilities of the measurements are also improved. The calibration curve is linear from 8 to 120 ng ml-1 of gallium or from 8 to 160 ng ml-1 of indium. Twenty seven diverse ions tested did not interfere seriously with either element. These methods are applicable to the determination of gallium and indium in river or seawater which contains down to 0.5 ng ml-1 of these elements. © 1988, The Japan Society for Analytical Chemistry. All rights reserved.
権利
権利情報 Copyright © The Japan Society for Analytical Chemistry 日本分析化学会
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 http://www.jsac.jp/
関連URI
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/browse/analsci
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:41:27.920778
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3