ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(理)

Graphite Furnace Atomic Absorption Spectrometric Determination of Bismuth(III) after Coprecipitation with Hafnium Hydroxide

http://hdl.handle.net/2297/38205
http://hdl.handle.net/2297/38205
9bb865ae-b8e3-4d7c-8b41-0136a1d7901c
名前 / ファイル ライセンス アクション
SC-PR-UEDA-J-544.pdf SC-PR-UEDA-J-544.pdf (607.3 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Graphite Furnace Atomic Absorption Spectrometric Determination of Bismuth(III) after Coprecipitation with Hafnium Hydroxide
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ueda, Joichi

× Ueda, Joichi

WEKO 15877

Ueda, Joichi

Search repository
Takagi, Midori

× Takagi, Midori

WEKO 15878

Takagi, Midori

Search repository
書誌情報 Bulletin of the Chemical Society of Japan

巻 63, 号 2, p. 544-547, 発行日 1990-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0009-2673
NCID
収録物識別子タイプ NCID
収録物識別子 AA00580132
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1246/bcsj.63.544
出版者
出版者 The Chemical Society of Japan = 日本化学会
抄録
内容記述タイプ Abstract
内容記述 A method for the coprecipitation of bismuth(III) with hafnium hydroxide followed by a graphite-furnace atomic absorption spectrometric determination is described. Hafnium hydroxide coprecipitates quantitatively 0.05–3 μg of bismuth(III) from 50–400 cm3 of sample solution at pH 5.8–11.2. The presence of 2.5–50 mg of hafnium in 25 cm3 does not affect the atomic absorbance of bismuth(III). The calibration curve is linear for 0.05–3 μg of bismuth(III) in 25 cm3 and passes through the origin. Interference from the presence of large amounts of silver can be eliminated by removing silver as the ammine complex produced by the coprecipitation procedure at above pH 11 with aqueous ammonia. Several other matrix ions investigated do not interfere with the determination in at least a 500-fold mass ratio to bismuth(III). This method was successfully applied to the determination of trace bismuth(III) in commercial metal silver (purity: 99.99%), and is also applicable to the determination of trace amounts of bismuth(III) in water sample.
権利
権利情報 Copyright © The Chemical Society of Japan 日本化学会
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/browse/bcsj
関連URI
識別子タイプ URI
関連識別子 http://www.chemistry.or.jp/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:40:20.990309
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3